ASTM F2095-2007e1 Standard Test Methods for Pressure Decay Leak Test for Flexible Packages With and Without Restraining Plates《有或无约束板的挠性包装件压力下降泄漏试验的标准试验方法》.pdf
《ASTM F2095-2007e1 Standard Test Methods for Pressure Decay Leak Test for Flexible Packages With and Without Restraining Plates《有或无约束板的挠性包装件压力下降泄漏试验的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2095-2007e1 Standard Test Methods for Pressure Decay Leak Test for Flexible Packages With and Without Restraining Plates《有或无约束板的挠性包装件压力下降泄漏试验的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2095 07e1Standard Test Methods forPressure Decay Leak Test for Flexible Packages With andWithout Restraining Plates1This standard is issued under the fixed designation F 2095; the number immediately following the designation indicates the year oforiginal adoption or, in the case of re
2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEAdded research report reference to Section 11 editorially in March 2008.1. Scope1.1 These test methods
3、cover the measurement of leaks innonporous film, foil, or laminate flexible pouches and foil-sealed trays, which may be empty or enclose solid product. Ifproduct is enclosed, seals or surfaces cannot be in contact withwater, oils, or other liquid.1.2 These test methods will detect leaks at a rate of
4、 1 3 104sccs (standard cubic centimetres per second) or greater, inflexible packages. The limitation of leak rate is dependent onpackage volume as tested.1.3 The following test methods are included:1.3.1 Test Method APressure Decay Leak Test for Flex-ible Packages Without Restraining Plates1.3.2 Tes
5、t Method BPressure Decay Leak Test for Flex-ible Packages With Restraining Plates1.4 These test methods are destructive in that they requireentry into the package to supply an internal pressure of gas,typically air or nitrogen, although other gases may be used.Theentry connection into the flexible p
6、ackage must be leak-tight.1.5 For porous packages, see 9.3.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bi
7、lity of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 4332 Practice for Conditioning Containers, Packages, orPackaging Components for TestingE 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 691 Practice for Conducting an Interlaboratory S
8、tudy toDetermine the Precision of a Test MethodF17 Terminology Relating to Flexible Barrier Packaging2.2 Other Document:ANSI/AAMI/ISO 116071:2006 Packaging for TerminallySterilized Medical DevicesPart 1: Requirements forMaterials, Sterile Barrier Systems, and Packaging Sys-tems33. Terminology3.1 Def
9、initions of Terms Specific to This Standard:3.1.1 integritythe unimpaired physical condition of thepackage. This implies that there are no leaks in the seals orbody materials.3.1.2 leakSee Terminology F17.3.1.3 nonporoustypes of materials that are not purposelydesigned to transfer gases through thei
10、r matrix.3.1.4 restraining platesplates of rigid material, for ex-ample, aluminum, that are used to restrict the movement of thepackage during inflation.3.1.5 sealSee Terminology F17.3.1.6 standard cubic centimetre per second (sccs)the flowrate of a gas (air) at standard conditions of 20C (68F) and1
11、01.3 kPa (14.7 psig) (1 atmosphere or 760 mm Hg).3.1.6.1 DiscussionConditions may be varied dependingon the source of data. Always check the definition being used.4. Summary of Test Method4.1 Detection of leak paths in flexible packages that havenonporous material surfaces and seals can be accomplis
12、hed bypressurization of the package to a fixed pressure, shutting offthe pressure and connecting a pressure transducer. Observedchanges in pressure indicate the presence of leakage paths inthe package seals or pinholes in the surfaces. This leak may berepresented in decay pressure units or calculate
13、d leak rateunits. To accomplish this technique, a leak-tight measuringpath must be available between the package interior volumeand the pressure transducer (see Fig. 1).1These test methods are under the jurisdiction of ASTM Committee F02 onFlexible Barrier Packaging and are the direct responsibility
14、 of Subcommittee F02.40on Package Integrity.Current edition approved Oct. 1, 2007. Published November 2007. Originallyapproved in 2001. Last previous edition approved in 2001 as F 2095 01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at service
15、astm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor
16、 Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.NOTE 1The coating used on porous barrier films will mask defects(pin-holes) in/through the porous material but not defects in the seals.4.2 Restraining plates may be used to limit the volume ofthe pressurized package. Because the s
17、ensitivity of these testmethods is dependent in part on the internal volume of thepackage, the effect of restraining plate use is to increase thesensitivity of the test (see Fig. 2). See Appendix X1 for furtherdiscussion of the effects of restraining plates on these testmethods.5. Significance and U
18、se5.1 These test methods provide a rapid, simple to applymethod to detect small leaks in flexible package seals or wallsat the leak rate level of greater than 1 3 104sccs, thusproviding a measure of package integrity. Porous barrier filmpackages made non-porous with an impermeable film formingcoatin
19、g may demonstrate lateral leakage through the barriermaterial. Verification of leakage differences from backgroundleakage must be included in validation methods. The use ofcalibrated hole sizes or orifices may be appropriate to deter-mine leakage sensitivity or barrier integrity for these materials.
20、5.2 While theoretical leak rate sensitivity can be establishedby calculation, the test measurement is in pressure units and themeasuring instrument must be calibrated, certified, and verifiedwith these units.FIG. 1 Leak-Tight Entry SystemFIG. 2 Restraining Fixture with Leak-Tight Entry SystemF209507
21、e125.3 The pressure decay method of leak testing is a physicalmeasure of package integrity. When testing medical packagingwhich must conform to ISO 116071: 2006 standards, it maynecessary to verify the results of the pressure decay test methodwith other sterile package integrity test methods.5.4 Tes
22、t Method A allows packages to be pressurizedwithout restraint. In Test Method A the pouch, tray, or othertype package will contain a volume of air defined by itsmechanical configuration and its ability to resist internalpressure applied. This test method requires that the packagereach a stable volum
23、e configuration (stop stretching) to make ameasurement.5.5 Test Method B allows the use of rigid restraining platesagainst the walls of the package to limit its volume andstabilize the package volume.6. Apparatus6.1 Test Method A:6.1.1 A measuring instrument that provides the following:6.1.1.1 A mea
24、ns to detect pressure changes with sufficientsensitivity to achieve theoretical leak rates in the packagespecification;6.1.1.2 Automatic timer controls to pressurize the packageto a preset pressure, hold the pressure for a set time, andprovide a time period during which pressure change data canbe ta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF20952007E1STANDARDTESTMETHODSFORPRESSUREDECAYLEAKTESTFORFLEXIBLEPACKAGESWITHANDWITHOUTRESTRAININGPLATES

链接地址:http://www.mydoc123.com/p-537734.html