ASTM E727 E727M-2008(2013) 9693 Standard Test Methods for Determining Bulk Density of Granular Carriers and Granular Pesticides《测定粒状载体与粒状农药的体积密度的标准试验方法》.pdf
《ASTM E727 E727M-2008(2013) 9693 Standard Test Methods for Determining Bulk Density of Granular Carriers and Granular Pesticides《测定粒状载体与粒状农药的体积密度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E727 E727M-2008(2013) 9693 Standard Test Methods for Determining Bulk Density of Granular Carriers and Granular Pesticides《测定粒状载体与粒状农药的体积密度的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E727/E727M 08 (Reapproved 2013)Standard Test Methods forDetermining Bulk Density of Granular Carriers and GranularPesticides1This standard is issued under the fixed designation E727/E727M; the number immediately following the designation indicates the yearof original adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods are used to determine bulk density ofgranular carriers and granular
3、pesticides by measuring eitherfree-fall bulk density (Test Method A) or loose-fill bulk density(Test Method B).1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem sh
4、all be used independently of the other. Combiningvalues from the two systems may result in nonconformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro
5、-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements see Section 4.2. Referenced Documents2.1 ASTM Standards:2E725 Test Method for Sampling Granular Carriers andGranular Pesticides3. Significance and Use3.1 These t
6、est methods were designed principally for clay,corncob, nut shell, paper-based or sand granular carriers, andgranular pesticide products, but need not be limited to thesematerials. There may be more appropriate test methods forother types of granular carriers or pesticide products. Thedifferences in
7、 the following test methods are slight, but theyoffer a choice of a recognized test procedure.4. Hazards4.1 Before testing granular pesticides, read the precaution-ary statements on the product label. Take proper precautions toprevent skin contact and inhalation of the fines and vapors.Take care to
8、prevent contamination of the surrounding area.Always wear the appropriate safety equipment and, whereindicated, wear respiratory devices approved by NIOSH for theproduct being tested.5. Summary of Test Method AFree-Fall Bulk Density5.1 A tared 500-mL cylinder is filled with the granularcarrier or gr
9、anular pesticide. The weight of the sample ismeasured and the bulk density calculated in pounds per cubicfoot or kilograms per cubic meter.6. Apparatus6.1 Balance, sensitivity of 1 g.6.2 Cylinder, graduated, capacity 500 mL. The cylindershould be calibrated at the 500-mL mark by using 499 g waterat
10、20C. The cylinder is cut off at the 500-mL mark and groundsmooth.6.3 Funnel, powder, 152 mm 6 in. in diameter at the top,bottom stem opening of 25-mm 1-in. diameter, and sideshaving a slope of approximately 60.6.4 Spatula, large with 51-mm 2-in. wide blade.6.5 Beaker, glass, metal, or plastic, 600-m
11、L capacity.6.6 Pan, metal or plastic, 203 mm 8 in. in diameter with51-mm 2-in. sides to collect overflow of cylinder.6.7 Ring Stand and Ring Clamp.7. Procedure7.1 Weigh the 500-mL graduated cylinder and place it in theoverflow pan.7.2 Support the funnel on a ring which is then affixed to aring stand
12、 such that the top of the funnel is horizontal andrigidly in position. Adjust the height of the funnel so that itsbottom position is 38 mm 1.5 in. above the top center of the500-mL graduated cylinder.7.3 Hold a piece of flat metal (such as a wide spatula orsimilar tool) against the bottom of the fun
13、nel stem. Fill a1These test methods are under the jurisdiction of ASTM Committee E35 onPesticides, Antimicrobials, and Alternative Control Agents and are the directresponsibility of Subcommittee E35.22 on Pesticide Formulations and DeliverySystems.Current edition approved Oct. 1, 2013. Published Mar
14、ch 2014. Originallyapproved in 1980. Last previous edition approved in 2008 as E727 08. DOI:10.1520/E0727_E0727M-08R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便