《ASTM E596-1996(2009) 5000 Standard Test Method for Laboratory Measurement of Noise Reduction of Sound-Isolating Enclosures《隔音室减少噪音的实验室测量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E596-1996(2009) 5000 Standard Test Method for Laboratory Measurement of Noise Reduction of Sound-Isolating Enclosures《隔音室减少噪音的实验室测量的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 596 96 (Reapproved 2009)Standard Test Method forLaboratory Measurement of Noise Reduction of Sound-Isolating Enclosures1This standard is issued under the fixed designation E 596; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test meth
3、od covers the reverberation room mea-surement of the noise reduction of sound-isolating enclosures.1.2 The noise isolation class may be determined from thenoise reduction measured in accordance with this test method.1.3 This standard does not purport to address all of thesafety concerns, if any, ass
4、ociated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 423 Test Method for Sound Absorption and Sound Ab-sorp
5、tion Coefficients by the Reverberation Room MethodC 634 Terminology Relating to Building and Environmen-tal AcousticsE 413 Classification for Rating Sound Insulation2.2 ANSI Standards:S1.4 Specification for Sound Level Meters3S1.11 Specification for Octave-Band and Fractional-Octave-Band Analog and
6、Digital Filters33. Terminology3.1 Definitions and SymbolsExcept as noted in 3.2, theterms and symbols used in this test method are defined inTerminology C 634.3.2 Definitions of Terms Specific to This Standard:3.2.1 sound-isolating enclosureany enclosure that com-pletely encloses a space, is intende
7、d to provide sound isolationfor the enclosed space, and can be tested in a reverberationroom.3.2.2 useful volume of a sound isolating enclosurethe partof the space inside the enclosure in which the noise reductionis of interest. For example, in an audiometric booth, the usefulvolume is the part of t
8、he space inside the booth where a testsubjects head is likely to be during audiometric tests.4. Summary of Test Method4.1 The enclosure to be tested is placed in a reverberationroom and prepared for testing. The background noise levelsinside the enclosure and in the reverberation room are mea-sured
9、in one-third octave bands. After bands of random noiseare produced in the reverberation room, one-third octave bandsound pressure levels are measured at several points in thereverberation room and at appropriate points inside the enclo-sure. The noise reduction in each one-third octave band is thedi
10、fference between the space-averaged sound pressure level inthe reverberation room and the space-averaged sound pressurelevel inside the enclosure. The noise isolation class (NIC) maybe determined from the noise reduction data.5. Significance and Use5.1 The noise reduction of an enclosure is a proper
11、ty of theenclosure, the location of the sound source used to measurenoise reduction, and the space in which the enclosure is placed.It is not a property of the enclosure alone, and its measurementunder different conditions can be expected to give differentresults. When the noise reduction is measure
12、d in accordancewith this test method, the sound source is outside the enclosureand the sound field outside the enclosure approximates adiffuse sound field. Measurements made in accordance withthis test method can be expected to be reproducible from onelaboratory to another.5.2 The noise reduction me
13、asured in accordance with thistest method may be used for the following purposes:5.2.1 To rank the order of sound-isolating enclosures ac-cording to noise isolation class, NIC.5.2.2 To estimate the highest one-third octave band soundpressure levels that can occur outside the enclosure withoutexceedi
14、ng specified sound pressure levels inside the enclosure.5.2.3 To estimate the one-third octave band sound pressurelevels that will occur inside the enclosure with specified soundpressure levels outside.1This test method is under the jurisdiction ofASTM Committee E33 on Buildingand Environmental Acou
15、stics and is the direct responsibility of SubcommitteeE33.03 on Sound Transmission.Current edition approved April 1, 2009. Published August 2009. Originallyapproved in 1977. Last previous edition approved in 2002 as E 596 96 (2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org
16、, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1C
17、opyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3 The noise reduction measured in accordance with thistest method may not estimate accurately the isolation that theenclosure will provide when it is used to isolate a noise sourceinsid
18、e it from the space outside. The user should be cautiouswhen using noise reductions measured by this test method toevaluate enclosures used to enclose noise sources.5.4 Sound-isolating enclosures are frequently made fromprefabricated modular panels. The noise reduction measuredby this test method ap
19、plies to the complete enclosure and notto individual panels from which it is made and cannot be usedto infer the sound transmission loss of the individual panels.5.5 Specifications for sound-isolating enclosures may in-clude reference to noise reduction and noise isolation classmeasured in accordanc
20、e with this test method.6. Reverberation Room6.1 Sound DiffusionThe sound field in the reverberationroom shall closely approximate a diffuse field when theenclosure to be tested is in place for testing. In general, therequirements for the reverberation room are those listed in thesection dealing wit
21、h Reverberation Room of Test MethodC 423. These requirements include:6.1.1 The effective room volume (actual room volumeminus the volume occupied by the enclosure) should not beless than 200 m3.NOTE 1Experience and experimental data have shown that as long asthe requirements of 9.1.2 and 9.5 are sat
22、isfied, the room volume is notcritical.6.1.2 The sound absorption in the reverberation room shallbe made as low as possible in order to achieve the best possiblesimulation to an ideal diffuse field and in order to keep theregion dominated by the direct field of the source as small aspossible. Within
23、 the frequency range described below thesound absorption of the reverberation room should be nogreater than the following:A 5 V2/3/3 (1)where:V = room volume, m3, andA = room sound absorption in metric sabins.For frequencies below f = 2000/V1/3(where the number 2000is an empirical constant with the
24、units seconds per metre),somewhat higher absorption may be desirable to accommodateother test requirements (for example, ANSI S1.32, ISO 3741);in any case, the absorption should be no greater than threetimes the value given by Eq 1. For frequencies above 2000 Hz,atmospheric absorption may make it im
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME596199620095000STANDARDTESTMETHODFORLABORATORYMEASUREMENTOFNOISEREDUCTIONOFSOUNDISOLATINGENCLOSURES

链接地址:http://www.mydoc123.com/p-533120.html