《ASTM E571-1998(2007)e1 459 Standard Practice for Electromagnetic (Eddy-Current) Examination of Nickel and Nickel Alloy Tubular Products《镍及镍合金管形制品的电磁(涡电流)检验的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E571-1998(2007)e1 459 Standard Practice for Electromagnetic (Eddy-Current) Examination of Nickel and Nickel Alloy Tubular Products《镍及镍合金管形制品的电磁(涡电流)检验的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 571 98 (Reapproved 2007)e1Standard Practice forElectromagnetic (Eddy-Current) Examination of Nickel andNickel Alloy Tubular Products1This standard is issued under the fixed designation E 571; the number immediately following the designation indicates the year oforiginal adoption or, i
2、n the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEEditorially changed “examination coils” to “test coils” in December 2007.1. Scope1.1 Th
3、is practice2covers the procedures for eddy-currentexamination of nickel and nickel alloy tubes. These proceduresare applicable for tubes with outside diameters up to 2 in. (50.8mm), incl, and wall thicknesses from 0.035 to 0.120 in. (0.889to 3.04 mm), incl. These procedures may be used for tubesbeyo
4、nd the size range recommended, by contractual agreementbetween the purchaser and the producer.1.2 The procedures described in this practice make use offixed encircling test coils or probe systems.1.3 The values stated in inch-pound units are to be regardedas the standard.NOTE 1For convenience, the t
5、erm “tube” or “tubular product” willhereinafter be used to refer to both pipe and tubing.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practice
6、s and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E 309 Practice for Eddy-Current Examination of Steel Tu-bular Products Using Magnetic SaturationE 543 Specification for Agencies Performing Nondestruc-tive TestingE 1316 Terminology f
7、or Nondestructive Examinations2.2 Other Documents:SNT-TC-1A Recommended Practice for Personnel Qualifi-cation and Certification in Nondestructive Testing4ANSI/ASNT-CP-189 ASNT Standard for Qualification andCertification of Nondestructive Testing Personnel4NAS-410 Certification and Qualification of N
8、ondestructivePersonnel (Quality Assurance Committee)53. Terminology3.1 Standard terminology relating to electromagnetic ex-amination may be found in Terminology E 1316, Section C,Electromagnetic Testing.4. Summary of Practice4.1 Examination is usually performed by the use of one oftwo general techni
9、ques:4.1.1 Encircling Coil TechniqueExamination is per-formed by passing the tube lengthwise through a coil energizedwith alternating current at one or more frequencies. See Fig. 1.The electrical impedance of the coil is modified by theproximity of the tube, the tube dimensions, electrical conduc-ti
10、vity, saturating magnetic field, magnetic permeability, andmetallurgical or mechanical discontinuities in the tube. As thetube passes through the coil, the changes in electromagneticresponse caused by these variables in the tube change the coilimpedance, which activates an audible or visual signalin
11、gdevice or a mechanical marker.4.1.2 Probe Coil TechniqueProbe coils are positioned inclose proximity to the outside diameter or to the insidediameter, or to both diameter surfaces, of the tubular productbeing examined as shown in Fig. 1. Since the probe is generallysmall and does not encircle the t
12、ube, it examines only a limitedarea in the vicinity of the probe. When required to examine theentire volume of the tubular product, it is common practice torotate either the tubular product or the probe around the tube.1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive
13、 Testing and is the direct responsibility of Subcommittee E07.07 onElectromagnetic Method.Current edition approved Dec. 1, 2007. Published January 2008. Originallyapproved in 1976. Last previous edition approved in 2003 as E 571 - 98(2003)e1.2For ASME Boiler and Pressure Vessel Code applications see
14、 related PracticeSE-571 in Section II of that Code.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available
15、 fromAmerican Society for Nondestructive Testing (ASNT), P.O. Box28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http:/www.asnt.org.5Available from Aerospace Industries Association of America, Inc. (AIA), 1000Wilson Blvd., Suite 1700,Arlington, VA22209-3928, http:/www.aia-aerospace.org.1Copyrigh
16、t ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Frequently, in the case of welded tubular products, only theweld is examined by scanning along the weld zone.4.2 The magnetic permeability of magnetic materials se-verely limits the depth of pen
17、etration of induced eddy currents.Furthermore, the permeability variations inherent in magnetictubular products can cause spurious test results. A usefulsolution to this problem involves the application of a strongexternal magnetic field in the region of the examining coil orprobe. This technique, k
18、nown as magnetic saturation, causes amagnetic material to exhibit sufficiently small magnetic char-acteristics of permeability, hysteresis, etc., so that the materialunder examination is effectively rendered nonmagnetic. Whenachieved, this condition allows an eddy-current system tomeasure and detect
19、 electrical resistivity and geometrical varia-tions (including defects) independent of concurrent variationsin magnetic properties.NOTE 2Practice E 309 may be used for strongly magnetic materials.4.2.1 During the examination of slightly magnetic tubingthe signals resulting from the variation of magn
20、etic permeabil-ity can mask the signals resulting from small imperfections. Amagnetic saturation technique can be used to reduce thisinterference to an acceptable level.5. Significance and Use5.1 Eddy-current examination is a nondestructive method oflocating discontinuities in metallic materials. Si
21、gnals can beproduced by discontinuities originating on either the externalor internal surfaces of the tube or by discontinuities totallycontained within the wall. Since the density of eddy currentsdecreases nearly exponentially with increasing distance fromthe surface nearest the coil, the response
22、to deep-seated defectsdecreases correspondingly. Phase changes are also associatedwith changes in depth, allowing the use of phase analysistechniques.5.2 The response from natural discontinuities can be signifi-cantly different than that from artificial discontinuities, such asdrilled holes or notch
23、es. For this reason, sufficient work shouldbe done to establish the sensitivity level and setup required todetect natural discontinuities of consequence to the end use ofthe product.5.3 Some indications obtained by this method may not berelevant to product quality; for example, an irrelevant indica-
24、tion may be caused by minute dents or tool chatter marks,which are not detrimental to the end use of the product.Irrelevant indications can mask unacceptable discontinuities.Relevant indications are those which result from discontinui-ties. Any indication that exceeds the rejection level shall betre
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME57119982007E1459STANDARDPRACTICEFORELECTROMAGNETICEDDYCURRENTEXAMINATIONOFNICKELANDNICKELALLOYTUBULARPRODUCTS

链接地址:http://www.mydoc123.com/p-533060.html