ASTM F180-1994(2010)e1 Standard Test Method for Density of Fine Wire and Ribbon Wire for Electronic Devices《电子装置用细金属线和带状金属线密度的标准试验方法》.pdf
《ASTM F180-1994(2010)e1 Standard Test Method for Density of Fine Wire and Ribbon Wire for Electronic Devices《电子装置用细金属线和带状金属线密度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F180-1994(2010)e1 Standard Test Method for Density of Fine Wire and Ribbon Wire for Electronic Devices《电子装置用细金属线和带状金属线密度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F180 94 (Reapproved 2010)1Standard Test Method forDensity of Fine Wire and Ribbon Wire for ElectronicDevices1This standard is issued under the fixed designation F180; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the
2、 year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.1NOTEThis standard was converted to solely SI units editorially in December 2010.1. Scope1.1 This test method covers the dete
3、rmination of, to anaccuracy of 1.0 %, the density of fine wires ranging from 0.25to 0.02 mm in diameter, or ribbons of similar thicknesses, forelectronic devices.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This stand
4、ard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements ar
5、e given in Section 4.2. Terminology2.1 Definition:2.1.1 densitythe weight per unit volume, expressed ingrams per cubic centimetre, in accordance with the followingequation:D5W/Vwhere:D = density of the specimenW = weight of the specimen, g, andV = volume of the specimen, cm3.3. Apparatus3.1 BalanceA
6、 suitable chemical balance capable of beingread to 0.1 mg.3.2 Micrometer, capable of being read to 0.002 mm.3.3 Standard Volume CylinderA cylinder of standardvolume made from corrosion-resistant material such as nickel,cylindrical in shape to within 0.0025 mm and of uniformdiameter and length. The l
7、ength of the cylinder shall beapproximately the same as the diameter and about 12.7 to 25.4mm. The surface of the cylinder shall be smooth and free fromdefects, pits, or cracks. The corners of the cylinder shall not berounded.3.4 Thermometer, capable of being read to 0.2C within therange from 10 to
8、35C.3.5 Vacuum Pump and DesiccatorA vacuum pump ca-pable of producing a vacuum of 0.1 mm Hg and a vacuumdesiccator.3.6 Hook suspended by a fine wire about 0.08 mm indiameter, both made of corrosion-resistant material, for sup-porting the test specimen while weighing it in the liquid.3.7 Cradle suspe
9、nded by a fine wire about 0.08 mm indiameter, both made of corrosion-resistant material, for sup-porting the standard volume cylinder while weighing it in thetest liquid.4. Test Liquid4.1 The test liquid in which the test specimen and standardvolume cylinder are to be immersed while being weighed sh
10、allbe pure, stable, and shall have a low viscosity, low surfacetension, low vapor pressure and a density of not less than 2g/cm3. Tetrabromoethane and tribromomethane have beenfound satisfactory for this purpose.4.2 Precaution2These liquids are moderately toxic andshould only be used by those famili
11、ar with the hazardsinvolved.4.2.1 Tests should be carried out under a fume hood. Thefluids used should be considered potentially dangerous.4.2.2 HazardWhen treated, highly toxic fumes are givenoff. Prolonged inhalation can cause unconsciousness.4.2.3 TreatmentFresh air; artificial respiration if unc
12、on-scious; oxygen if required.5. Test Specimen5.1 The preferred length of wire or ribbon required for thetest specimen shall be such that the volume is approximately0.5 cm3. The use of a specimen of less than 0.2 cm3is notrecommended.1This test method is under the jurisdiction of ASTM Committee F01
13、onElectronics and is the direct responsibility of Subcommittee F01.03 on MetallicMaterials.Current edition approved Dec. 1, 2010. Published January 2011. Originallyapproved in 1943 as B180 43 T. Last previous edition approved in 2005 asF180 94 (2005). DOI: 10.1520/F0180-94R10.2See Sax, N. I., Handbo
14、ok of Dangerous Materials, 1951.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6. Preparation of Specimen6.1 The wire or ribbon shall be wiped and loosely woundinto a small coil and bound with wire of the same compositionin such a m
15、anner that no loose ends project from the body ofthe coil in order to produce a compact coil sufficiently looselywound to permit penetration of the test liquid upon immersion.The test specimen shall be thoroughly cleaned of lubricants bywashing or boiling in suitable solvents and thoroughly dryingin
16、 an oven.7. Procedure7.1 Weigh the test specimen in air to the nearest 0.1 mg.Pour sufficient test liquid into a beaker to completely covereither the test specimen or the standard volume cylinder (see7.4) when suspended by their respective supports in the liquidfor weighing (Note 2). Immerse the spe
17、cimen in the liquid, andplace the beaker containing the specimen entirely submerged inthe vacuum desiccator. The vacuum produced by the pumpshall be sufficient to bring the liquid to a slow boil at roomtemperature and the boiling shall be continued for 10 to 15min. During this boiling period, jar or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF18019942010E1STANDARDTESTMETHODFORDENSITYOFFINEWIREANDRIBBONWIREFORELECTRONICDEVICES 电子 装置 金属线 带状

链接地址:http://www.mydoc123.com/p-532492.html