《ASTM E177-2014 red 8144 Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods《ASTM试验方法中术语精确性和偏差的使用规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E177-2014 red 8144 Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods《ASTM试验方法中术语精确性和偏差的使用规程》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E177 13E177 14 An American National StandardStandard Practice forUse of the Terms Precision and Bias in ASTM Test Methods1This standard is issued under the fixed designation E177; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 The purpos
3、e of this practice is to present concepts necessary to the understanding of the terms “precision” and “bias” as usedin quantitative test methods. This practice also describes methods of expressing precision and bias and, in a final section, givesexamples of how statements on precision and bias may b
4、e written for ASTM test methods.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatoryrequiremen
5、ts prior to use.2. Referenced Documents2.1 ASTM Standards:2E456 Terminology Relating to Quality and StatisticsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test MethodE1488 Guide for Statistical Procedures to Use in Developing and Applying Test MethodsE2282 Gu
6、ide for Defining the Test Result of a Test MethodE2586 Practice for Calculating and Using Basic StatisticsE2587 Practice for Use of Control Charts in Statistical Process Control3. Terminology3.1 DefinitionsTerminology E456 provides a more extensive list of terms in E11 standards.3.1.1 accepted refer
7、ence value, na value that serves as an agreed-upon reference for comparison, and which is derived as: (1)a theoretical or established value, based on scientific principles, (2) an assigned or certified value, based on experimental work ofsome national or international organization, or (3) a consensu
8、s or certified value, based on collaborative experimental work underthe auspices of a scientific or engineering group.3.1.1.1 DiscussionAnational or international organization, referred to in 3.1.1 (2), generally maintains measurement standards to which the referencevalues obtained are traceable.3.1
9、.2 accuracy, nthe closeness of agreement between a test result and an accepted reference value.3.1.2.1 DiscussionThe term accuracy, when applied to a set of test results, involves a combination of a random component and of a commonsystematic error or bias component.3.1.3 bias, nthe difference betwee
10、n the expectation of the test results and an accepted reference value.1 This practice is under the jurisdiction of ASTM Committee E11 on Quality and Statistics and is the direct responsibility of Subcommittee E11.20 on Test MethodEvaluation and Quality Control.Current edition approved May 1, 2013May
11、 1, 2014. Published May 2013May 2014. Originally approved in 1961. Last previous edition approved in 20102013 asE177 10.E177 13. DOI: 10.1520/E0177-13.10.1520/E0177-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual
12、Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be tec
13、hnically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO
14、 Box C700, West Conshohocken, PA 19428-2959. United States13.1.3.1 DiscussionBias is the total systematic error as contrasted to random error.There may be one or more systematic error components contributingto the bias. A larger systematic difference from the accepted reference value is reflected by
15、 a larger bias value.3.1.4 characteristic, na property of items in a sample or population which, when measured, counted or otherwise observed,helps to distinguish between the items. E22823.1.5 coeffcient of variation, CV, nfor a nonnegative characteristic, the ratio of the standard deviation to the
16、mean for apopulation or sample. E25863.1.6 intermediate precision, nthe closeness of agreement between test results obtained under specified intermediate precisionconditions.3.1.6.1 DiscussionThe specific measure and the specific conditions must be specified for each intermediate measure of precisio
17、n; thus, “standarddeviation of test results among operators in a laboratory,” or “day-to-day standard deviation within a laboratory for the sameoperator.”3.1.6.2 DiscussionBecause the training of operators, the agreement of different pieces of equipment in the same laboratory and the variation ofenv
18、ironmental conditions with longer time intervals all depend on the degree of within-laboratory control, the intermediatemeasures of precision are likely to vary appreciably from laboratory to laboratory. Thus, intermediate precisions may be morecharacteristic of individual laboratories than of the t
19、est method.3.1.7 intermediate precision conditions, nconditions under which test results are obtained with the same test method using testunits or test specimens taken at random from a single quantity of material that is as nearly homogeneous as possible, and withchanging conditions such as operator
20、, measuring equipment, location within the laboratory, and time.3.1.8 observation, nthe process of obtaining information regarding the presence or absence of an attribute of a test specimen,or of making a reading on a characteristic or dimension of a test specimen. E22823.1.9 observed value, nthe va
21、lue obtained by making an observation. E22823.1.10 precision, nthe closeness of agreement between independent test results obtained under stipulated conditions.3.1.10.1 DiscussionPrecision depends on random errors and does not relate to the accepted reference value.3.1.10.2 DiscussionThe measure of
22、precision usually is expressed in terms of imprecision and computed as a standard deviation of the test results. Lessprecision is reflected by a larger standard deviation.3.1.10.3 Discussion“Independent test results” means results obtained in a manner not influenced by any previous result on the sam
23、e or similar testobject. Quantitative measures of precision depend critically on the stipulated conditions. Repeatability and reproducibilityconditions are particular sets of extreme stipulated conditions.3.1.11 repeatability, nprecision under repeatability conditions.3.1.11.1 DiscussionRepeatabilit
24、y is one of the concepts or categories of the precision of a test method.3.1.11.2 DiscussionMeasures of repeatability defined in this compilation are repeatability standard deviation and repeatability limit.E177 1423.1.12 repeatability conditions, nconditions where independent test results are obtai
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME1772014RED8144STANDARDPRACTICEFORUSEOFTHETERMSPRECISIONANDBIASINASTMTESTMETHODSASTM 试验 方法 术语 精确性

链接地址:http://www.mydoc123.com/p-527063.html