ASTM D7475-2011 5000 Standard Test Method for Determining the Aerobic Degradation and Anaerobic Biodegradation of Plastic Materials under Accelerated Bioreactor Landfill Conditions.pdf
《ASTM D7475-2011 5000 Standard Test Method for Determining the Aerobic Degradation and Anaerobic Biodegradation of Plastic Materials under Accelerated Bioreactor Landfill Conditions.pdf》由会员分享,可在线阅读,更多相关《ASTM D7475-2011 5000 Standard Test Method for Determining the Aerobic Degradation and Anaerobic Biodegradation of Plastic Materials under Accelerated Bioreactor Landfill Conditions.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7475 11Standard Test Method forDetermining the Aerobic Degradation and AnaerobicBiodegradation of Plastic Materials under AcceleratedBioreactor Landfill Conditions1This standard is issued under the fixed designation D7475; the number immediately following the designation indicates the
2、year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This modification of Test Method D5526, which onlyco
3、nsidered anaerobic degradation, is used to determine thedegree and rate of aerobic degradation (as indicated by loss oftensile strength, molecular weight, possibly resulting in disin-tegration and fragmentation) and anaerobic biodegradation ofplastic materials in an accelerated bioreactor landfill t
4、estenvironment. It simulates the change from aerobic to anaerobicenvironments over time as landfill depth increases. Plasticmaterials found in landfills include discarded plastic productssuch as bags and wrappers and also deliberately applied plasticcovers as inter-layer sealers between daily refuse
5、 fills toprevent windblown scatter of garbage overnight or at otherdown times. This modification is a two-tiered test method inwhich the two tiers, which address aerobic degradation andanaerobic biodegradation, are most preferably run sequentiallyto more closely resemble the real world condition of
6、abiologically active landfill, or a bioreactor landfill, but arefunctional independently and separately depending on theplastic under evaluation and the information sought: eitheraerobic degradation or anaerobic biodegradation or both. Thetiered system approach is shown schematically in Fig. 1.InTie
7、r 1, the test plastic material is mixed with household waste,then pretreated and stabilized aerobically in the presence of air,in a sealed vessel in a temperature range that is consistent withthe average temperature range of those recorded for landfillsfor a time period of four weeks. The tier is an
8、 acceleratedsimulation of degradation with concomitant oxygen consump-tion and depletion with time as if oxidative degradationproceeds. In Tier 2 samples of the plastic materials pretreatedaerobically as described in Tier 1, are exposed to a methano-genic inoculum derived from anaerobic digesters op
9、eratingonly on pretreated household waste. The anaerobic decompo-sition and biodegradation occur under dry (more than 30 %total solids) and static non-mixed conditions. If it is desired toonly assess anaerobic biodegradation of a plastic material, Tier2 is run using preconditioned household waste, a
10、s described inTier 1 but without the added plastic. The mixtures obtainedfrom Tier 1 and Tier 2 in this test method are sampled and usedto assess the environmental and health risks of plastic materialsthat are degraded in a landfill under aerobic and anaerobicconditions.1.2 This test method generate
11、s comparative data for severalmaterials and must not be used to make claims regardingbenefits of placing degradable or biodegradable plastics inlandfills. Claims must be limited to and dependent on theresults obtained from each tier.1.2.1 If only Tier 1 is run, then the claims must state: Willmodify
12、 the performance/physical properties (for example,mechanical properties will degrade), up to a measured percent,X%, in a given time period, Y days using Test Methods D3593(Molecular weight change) and Test Method D3826 (tensilestrength change) in a biologically active “bioreactor” landfill.Report me
13、asured percent property changes and standards usedto measure the test results which are, for example, changes intensile strength, mass and molecular weight, as well as residualparticle size ranges in Section 14 to support the extent of suchclaims.1.2.2 If both Tier 1 and Tier 2 are run, then claims
14、shallstate: Will biodegrade in a biologically active “bioreactor”landfill to a degree, X%, in Y days established by the testresults based on the extent to which the plastic sample isconverted to gaseous carbon in the form of carbon dioxide andmethane and this shall be made available according to Sec
15、tion14 to support the extent of such claims. It should be noted thatbiodegradation testing is very dependent on conditions chosenin this laboratory test and may well vary widely when the testis run with different inoculum, The results reported pertain onlyto the test conditions run and do not rule o
16、ut potentialbiodegradation under other conditions and real world environ-ments.1.3 Tier 1 of this test method is designed to estimate theaerobic degradation of plastics, that is disintegration andfragmentation, only, by measuring the loss of physical andchemical properties of said plastics. The test
17、 environment isthen changed to that of Tier 2, an anaerobic condition, andbiodegradation is measured by a combination of evolved1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.96 on EnvironmentallyDegradable Plastics a
18、nd Biobased Products.Current edition approved Jan. 1, 2011. Published February 2011. DOI:10.1520/D7475-11.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.carbon dioxide and methane gases as a percentage of theconversion of carbon in
19、the plastic sample to carbon in thegaseous form under conditions that resemble landfill condi-tions. This test method does not simulate all conditions foundin landfills, especially those found in biologically inactivelandfills. This test method more closely resembles those typesof bioreactor landfil
20、ls in which the gas generated is recoveredor even actively promoted, or both, for example, by inoculation(co-deposition of anaerobic sewage sludge and anaerobicleachate recirculation), moisture control in the landfill(leachate recirculation), and temperature control (short-terminjection of oxygen an
21、d heating of re-circulated leachate)(1-7).21.4 This test method produces partially degraded mixturesof municipal solid waste and plastics that, where required, areused to assess the ecotoxicological risks associated with thedegradation of plastics after various stages of aerobic degra-dation and ana
22、erobic biodegradation in a landfill.1.5 The intended use of this method is for a comparison andranking of aerobic degradation and anaerobic biodegradationof plastics after disposal in a bioreactor landfill. It is notdesigned or intended to be used to support claims recommend-ing the value of plastic
23、 degradation in full-scale landfills. Thissimulation of an active landfill allows measurement of thepercentage of aerobic degradation and anaerobic biodegrada-tion (biogas evolution) in specified time periods, only.1.6 Though the test method is in two tiers, they are meant tosimulate a real world cy
24、cle of degradation in a landfill and aremost preferably run consecutively and not independently orseparately1.7 It is cautioned that the results of any laboratory landfillsimulation cannot be directly extrapolated to actual disposalenvironments: confirmation to real world exposure is ulti-mately req
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD747520115000STANDARDTESTMETHODFORDETERMININGTHEAEROBICDEGRADATIONANDANAEROBICBIODEGRADATIONOFPLASTICMATERIALSUNDERACCELERATEDBIOREACTORLANDFILLCONDITIONSPDF

链接地址:http://www.mydoc123.com/p-525599.html