ASTM D6299-2017 5073 Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance《利用统计质量保证和控制图.pdf
《ASTM D6299-2017 5073 Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance《利用统计质量保证和控制图.pdf》由会员分享,可在线阅读,更多相关《ASTM D6299-2017 5073 Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance《利用统计质量保证和控制图.pdf(29页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6299 17 An American National StandardStandard Practice forApplying Statistical Quality Assurance and Control ChartingTechniques to Evaluate Analytical Measurement SystemPerformance1This standard is issued under the fixed designation D6299; the number immediately following the designati
2、on indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers information f
3、or the design andoperation of a program to monitor and control ongoing stabilityand precision and bias performance of selected analyticalmeasurement systems using a collection of generally acceptedstatistical quality control (SQC) procedures and tools.NOTE 1A complete list of criteria for selecting
4、measurement systemsto which this practice should be applied and for determining the frequencyat which it should be applied is beyond the scope of this practice.However, some factors to be considered include (1) frequency of use ofthe analytical measurement system, (2) criticality of the parameter be
5、ingmeasured, (3) system stability and precision performance based onhistorical data, (4) business economics, and (5) regulatory, contractual, ortest method requirements.1.2 This practice is applicable to stable analytical measure-ment systems that produce results on a continuous numericalscale.1.3 T
6、his practice is applicable to laboratory test methods.1.4 This practice is applicable to validated process streamanalyzers.1.5 This practice is applicable to monitoring the differencesbetween two analytical measurement systems that purport tomeasure the same property provided that both systems haveb
7、een assessed in accordance with the statistical methodology inPractice D6708 and the appropriate bias applied.NOTE 2For validation of univariate process stream analyzers, see alsoPractice D3764.NOTE 3One or both of the analytical systems in 1.5 can be laboratorytest methods or validated process stre
8、am analyzers.1.6 This practice assumes that the normal (Gaussian) modelis adequate for the description and prediction of measurementsystem behavior when it is in a state of statistical control.NOTE 4For non-Gaussian processes, transformations of test resultsmay permit proper application of these too
9、ls. Consult a statistician forfurther guidance and information.2. Referenced Documents2.1 ASTM Standards:2D3764 Practice for Validation of the Performance of ProcessStream Analyzer SystemsD5191 Test Method for Vapor Pressure of Petroleum Prod-ucts (Mini Method)D6708 Practice for Statistical Assessme
10、nt and Improvementof Expected Agreement Between Two Test Methods thatPurport to Measure the Same Property of a MaterialD6792 Practice for Quality System in Petroleum Productsand Lubricants Testing LaboratoriesD7372 Guide for Analysis and Interpretation of ProficiencyTest Program ResultsE177 Practice
11、 for Use of the Terms Precision and Bias inASTM Test MethodsE178 Practice for Dealing With Outlying ObservationsE456 Terminology Relating to Quality and StatisticsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 Definitions:3.1.1 accep
12、ted reference value, na value that serves as anagreed-upon reference for comparison and that is derived as (1)a theoretical or established value, based on scientific principles,(2) an assigned value, based on experimental work of somenational or international organization, such as the U.S. Na-tional
13、 Institute of Standards and Technology (NIST), or (3)aconsensus value, based on collaborative experimental workunder the auspices of a scientific or engineering group. E177,E4563.1.2 accuracy, nthe closeness of agreement between anobserved value and an accepted reference value. E177, E4563.1.3 assig
14、nable cause, na factor that contributes to varia-tion and that is feasible to detect and identify. E4561This practice is under the jurisdiction of ASTM Committee D02 on PetroleumProducts, Liquid Fuels, and Lubricants and is the direct responsibility of Subcom-mittee D02.94 on Coordinating Subcommitt
15、ee on Quality Assurance and Statistics.Current edition approved Jan. 1, 2017. Published January 2017. Originallyapproved in 1998. Last previous edition approved in 2016 as D6299 16. DOI:10.1520/D6299-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Ser
16、vice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428
17、-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technic
18、al Barriers to Trade (TBT) Committee.13.1.4 bias, na systematic error that contributes to thedifference between a population mean of the measurements ortest results and an accepted reference or true value. E177, E4563.1.5 control limits, nlimits on a control chart that areused as criteria for signal
19、ing the need for action or for judgingwhether a set of data does or does not indicate a state ofstatistical control. E4563.1.6 lot, na definite quantity of a product or materialaccumulated under conditions that are considered uniform forsampling purposes. E4563.1.7 precision, nthe closeness of agree
20、ment between testresults obtained under prescribed conditions. E4563.1.8 repeatability conditions, nconditions where mutu-ally independent test results are obtained with the same testmethod in the same laboratory by the same operator with thesame equipment within short intervals of time, using tests
21、pecimens taken at random from a single sample of material.3.1.9 reproducibility conditions, nconditions under whichtest results are obtained in different laboratories with the sametest method, using test specimens taken at random from thesame sample of material.3.2 Definitions of Terms Specific to T
22、his Standard:3.2.1 analytical measurement system, na collection of oneor more components or subsystems, such as samplers, testequipment, instrumentation, display devices, data handlers,printouts or output transmitters, that is used to determine aquantitative value of a specific property for an unkno
23、wnsample in accordance with a test method.3.2.1.1 DiscussionA standard test method (for example,ASTM, ISO) is an example of an analytical measurementsystem.3.2.1.2 DiscussionAn analytical measurement systemmay comprise multiple instruments being used for the sametest method provided there is no stat
24、istically observable biasand precision differences between the multiple instruments.3.2.2 blind submission, nsubmission of a check standardor quality control (QC) sample for analysis without revealingthe expected value to the person performing the analysis.3.2.3 check standard, nin QC testing, a mat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD629920175073STANDARDPRACTICEFORAPPLYINGSTATISTICALQUALITYASSURANCEANDCONTROLCHARTINGTECHNIQUESTOEVALUATEANALYTICALMEASUREMENTSYSTEMPERFORMANCE

链接地址:http://www.mydoc123.com/p-522104.html