ASTM D5348-1995(2006) Standard Test Method for Determination of the Moisture Content of Sulfonated and Sulfated Oils by Distillation with Xylene《用二甲苯蒸馏测量碘化油和硫酸盐油中的水含量的标准试验方法》.pdf
《ASTM D5348-1995(2006) Standard Test Method for Determination of the Moisture Content of Sulfonated and Sulfated Oils by Distillation with Xylene《用二甲苯蒸馏测量碘化油和硫酸盐油中的水含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5348-1995(2006) Standard Test Method for Determination of the Moisture Content of Sulfonated and Sulfated Oils by Distillation with Xylene《用二甲苯蒸馏测量碘化油和硫酸盐油中的水含量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5348 95 (Reapproved 2006)Standard Test Method forDetermination of the Moisture Content of Sulfonated andSulfated Oils by Distillation with Xylene1This standard is issued under the fixed designation D 5348; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of waterexisting in a sam
3、ple of sulfonated or sulfated oil, or both, bydistilling the sample with a volatile solvent. The test method isapplicable only to sulfonated and sulfated oils that do notcontain the following: mineral acids, free sulfonic acids, or freesulfuric acid esters; or alkali hydroxides, carbonates or ac-eta
4、tes: or alcohol, glycerin, diethylene glycol, acetone, or otherwater-miscible volatile compounds. This test method wasderived from Test Methods D 500, Sections 4 through 9.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are provided forinformation
5、 only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Refere
6、nced Documents2.1 ASTM Standards:2D 500 Test Methods of Chemical Analysis of Sulfonatedand Sulfated Oils3. Significance and Use3.1 This test method is intended to determine the moisturecontent of fats, oils, and fatliquors used in the softening andstuffing of leather. The moisture content is measure
7、d for thepurpose of quality assurance.4. Apparatus4.1 The apparatus required consists of a glass flask heatedby suitable means and provided with a reflux condenserdischarging into a trap and connected to the flask. Theconnections between the trap and the condenser and flask shallbe interchangeable g
8、round joints. The trap serves to collect andmeasure the condensed water and to return the solvent to theflask. A suitable assembly of the apparatus is illustrated in Fig.1.4.1.1 Flask, 500-mL, of either the short-neck, round-bottomtype or the Erlenmeyer type.4.1.2 Heat SourceThe source of heat may b
9、e either an oilbath (stearic acid, paraffin wax, etc.), or an electric heaterprovided with a sliding rheostat or other means of heat control.4.1.3 Condenser, a water-cooled glass reflux condenser(Fig. 1), having a jacket approximately 400 mm (1534 in.) inlength with an inner tube 9.5 to 12.7 mm (38
10、to12 in.) inoutside diameter. The end of the condenser to be inserted in thetrap shall be ground off at an angle of 30 from the vertical axisof the condenser. When inserted into the trap, the tip of thecondenser shall be about 7 mm (14 in.) above the surface of theliquid in the trap after the distil
11、lation conditions have beenestablished. Fig. 1 shows a conventional sealed-in type ofcondenser, but any other condenser fulfilling the detailedrequirements above may be used.4.1.4 Trap, a trap made of well-annealed glass constructedin accordance with Fig. 1 and graduated as shown to contain 5mL at 2
12、0C. It shall be subdivided into 0.1-mL divisions, witheach 1-mL line numbered (5 mL at top). The error in anyindicated capacity may not be greater than 0.05 mL.5. Purity of Reagents5.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended tha
13、tall reagents shall conform to the specifications of the Commit-tee onAnalytical Reagents of theAmerican Chemical Society.36. Reagents6.1 Oleic Acid, heated previous to use for 5 to 10 min overa free flame at a temperature of 130 to 135C.1This test method is under the jurisdiction of ASTM Committee
14、D31 on Leatherand is the direct responsibility of Subcommittee D31.08 on Fats and Oils. This testmethod was developed in cooperation with the American Leather Chemists Assn.(Method H 40-1957).Current edition approved April 1, 2006. Published April 2006. Originallyapproved in 1993. Last previous edit
15、ion approved in 2001 as D 5348 95(2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals, A
16、merican Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formul
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD534819952006STANDARDTESTMETHODFORDETERMINATIONOFTHEMOISTURECONTENTOFSULFONATEDANDSULFATEDOILSBYDISTILLATIONWITHXYLENE

链接地址:http://www.mydoc123.com/p-519540.html