ASTM D5322-1998(2003) Standard Practice for Immersion Procedures for Evaluating the Chemical Resistance of Geosynthetics to Liquids《评价土工合成织物耐液体化学侵蚀性用的浸入程序的标准操作规程》.pdf
《ASTM D5322-1998(2003) Standard Practice for Immersion Procedures for Evaluating the Chemical Resistance of Geosynthetics to Liquids《评价土工合成织物耐液体化学侵蚀性用的浸入程序的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5322-1998(2003) Standard Practice for Immersion Procedures for Evaluating the Chemical Resistance of Geosynthetics to Liquids《评价土工合成织物耐液体化学侵蚀性用的浸入程序的标准操作规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5322 98 (Reapproved 2003)Standard Practice forLaboratory Immersion Procedures for Evaluating theChemical Resistance of Geosynthetics to Liquids1This standard is issued under the fixed designation D 5322; the number immediately following the designation indicates the year oforiginal ad
2、option or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers laboratory immersion proceduresfor the testing o
3、f geosynthetics for chemical resistance to liquidwastes, prepared chemical solutions, and leachates derivedfrom solid wastes.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all
4、of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardsstatements, see Section 7.2. Referenced Docu
5、ments2.1 ASTM Standards:D 123 Terminology Relating to Textiles2D 471 Test Method for Rubber PropertyEffect of Liq-uids3D 543 Test Method for Resistance of Plastics to ChemicalReagents4D 4439 Terminology for Geotextiles5D 5747 Practice for Tests to Evaluate the Chemical Resis-tance of Geomembranes to
6、 Liquids52.2 Other Document:SW 846, Method 9090 Compatibility Test for Wastes andMembrane Liners63. Terminology3.1 DefinitionsFor definitions of many terms used in thispractice, refer to Terminologies D 123 and D 4439.3.2 Descriptions of Terms Specific to This Standard:3.2.1 chemical resistancethe a
7、bility to resist chemicalattack.3.2.1.1 DiscussionThe attack is dependent on the testmethod, and its severity is measured by determining thechanges in physical properties. Time, temperature, stress, andreagent may all be factors affecting the chemical resistance ofa material.3.2.2 geosynthetic, na p
8、lanar product manufactured frompolymeric material used with soil, rock, earth, or other geo-technical engineering-related material as an integral part of aman-made project, structure, or system.4. Significance and Use4.1 This practice provides a standard immersion procedurefor investigating the chem
9、ical resistance of a geosynthetic to aliquid waste, leachate, or chemical. The conditions specified inthis practice are intended both to provide a basis of standard-ization and to serve as a guide for those wishing to compare orinvestigate the chemical resistance of a geosynthetic materi-al(s).4.2 T
10、his practice is not intended to establish, by itself, thebehavior of geosynthetics when exposed to liquids. Suchbehavior, referred to as chemical resistance, can be definedonly in terms of specific chemical solutions and methods oftesting and evaluation criteria selected by the user.4.3 Without regu
11、latory approval, this practice does notsupersede testing requirements, such as SW 846, Method 9090,stipulated by regulatory agencies.5. Apparatus5.1 Exposure Tank, for containment of the solution and testmaterial. The tank must be chemically resistant and imperme-able to the solution being used. Sta
12、inless steel or glass isrecommended. Glass should not be used with strongly basicsolutions.5.1.1 The size of the exposure tank is not specified since thevolume of liquid to be used with any given amount ofimmersed geosynthetic has not been standardized by ASTM orspecified by the Environmental Protec
13、tion Agency at the timeof the writing of this practice. Sufficient liquid must be used toensure the presence of any potentially detrimental chemicals1This practice is under the jurisdiction of ASTM Committee D35 on Geosyn-thetics and is the direct responsibility of Subcommittee D35.02 on EndurancePr
14、operties.Current edition approved May 10, 1998. Published August 1998. Originallypublished as D 5322 92. Last previous edition D 5322 92.2Annual Book of ASTM Standards, Vol 07.01.3Annual Book of ASTM Standards, Vol 09.01.4Annual Book of ASTM Standards, Vol 08.01.5Annual Book of ASTM Standards, Vol 0
15、4.13.6Available from US EPA, Office of Solid Waste and Emergency Response, TestMethods for Evaluating Solid Waste, Physical/Chemical Methods.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.throughout the immersion. If sufficiently la
16、rge exposure tanksare not possible, or if it is suspected that trace amounts ofchemicals may be depleted from the liquid during the expo-sure, smaller tanks may be used if the immersion liquid isreplaced with fresh solution after each test period.5.2 Exposure Tank Lid, for sealing the tank. In order
17、 toprevent the loss of volatile components of interest, the tankmust be capable of being sealed with a chemically resistantmaterial.5.2.1 Unless otherwise specified, agreed upon, or required,provisions must be made for maintaining ambient atmosphericpressure in the tank. Using a reflex condenser ope
18、n to the air,a pressure relief valve or any method allowing the movementof gas to relieve pressure while minimizing changes in thechemical composition of the test solution is acceptable (see9.7). The purpose of this feature of the equipment is to preventpressure buildup in an exposure tank from the
19、generation ofgases by chemical reactions or biological activity.5.2.2 Pressurized tanks that maintain a constant pressuremay be used as an alternative to 5.2.1 when the maintenance ofa pressure other than ambient atmospheric pressure is speci-fied, agreed upon, or required.5.3 Temperature Control Eq
20、uipment, to maintain the immer-sion solution at the specified temperature. Options that haveworked well are the following: (1) a hot water bath to containthe exposure tank; (2) a heating coil wrapped around the tank,or a hot plate used in conjunction with a thermostat andthermocouple; and (3) a room
21、 controlled at the exposuretemperature for storing the tank. Placing a heating coil directlyin the exposure solution is not recommended since corrosionmay affect the coil, and chemical reactions that may nototherwise occur may occur on a hot coil.5.4 Stirrer, if required (see 9.4), for mixing the so
22、lution.Magnetically moved stirring bars and mechanical stirrersentering the tank through the lid will both work, depending onthe temperature control procedure.6. Reagents and Materials6.1 Immersion SolutionThe solutions potentially usedwith this practice have large differences in origin. The user of
23、this practice must determine the correct solution for use in theparticular application. Liquid wastes, leachates collected fromexisting installations, leachates made from solid wastes, syn-thetic leachates made from laboratory chemicals, standardchemical solutions (Test Method D 543), and reference
24、fuelsand oils (Test Method D 471) are some of the possibilities.7. Hazards7.1 The solutions used in this practice may contain hazard-ous chemicals. Precautions must be taken when handlinghazardous waste, chemicals, and immersion solutions. Protec-tive equipment suitable for the chemicals being used
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD532219982003STANDARDPRACTICEFORIMMERSIONPROCEDURESFOREVALUATINGTHECHEMICALRESISTANCEOFGEOSYNTHETICSTOLIQUIDS

链接地址:http://www.mydoc123.com/p-519472.html