ASTM D4568-1999(2009) Standard Test Methods for Evaluating Compatibility Between Cable Filling and Flooding Compounds And Polyolefin Wire and Cable Materials《评价电缆填充物、溢流件、聚烯烃线和电缆材料间.pdf
《ASTM D4568-1999(2009) Standard Test Methods for Evaluating Compatibility Between Cable Filling and Flooding Compounds And Polyolefin Wire and Cable Materials《评价电缆填充物、溢流件、聚烯烃线和电缆材料间.pdf》由会员分享,可在线阅读,更多相关《ASTM D4568-1999(2009) Standard Test Methods for Evaluating Compatibility Between Cable Filling and Flooding Compounds And Polyolefin Wire and Cable Materials《评价电缆填充物、溢流件、聚烯烃线和电缆材料间.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4568 99 (Reapproved 2009)An American National StandardStandard Test Methods forEvaluating Compatibility Between Cable Filling andFlooding Compounds And Polyolefin Wire and CableMaterials1This standard is issued under the fixed designation D4568; the number immediately following the des
2、ignation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods evaluate t
3、he compatibility betweencable filling or cable flooding compounds, or both, andpolyolefin materials used in the manufacture of wire and cablethat are usually in intimate contact with the filler or floodant, orboth.1.2 These test methods are useful to ensure compatibilityand to verify that new formul
4、ations of filling or floodingcompounds will have no deleterious effect upon the otherpolyolefin materials being used or, conversely, use thesemethods to ensure that other polyolefin wire and cable mate-rials are evaluated for possible use not degraded by contactwith fillers or floodants already in u
5、se.1.3 Whenever two sets of values are presented, in differentunits, the values in the first set are the standard, while those inparentheses are for information only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of t
6、he user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1711 Terminology Relating to Electrical Insulation3D1928 Practice for Preparation of Compression-MoldedPo
7、lyethylene Test Sheets and Test Specimens3D2633 Test Methods for Thermoplastic Insulations andJackets for Wire and CableD4730 Specification for Flooding Compounds for Telecom-munications Wire and CableD4731 Specification for Hot-Application Filling Com-pounds for Telecommunications Wire and CableD47
8、32 Specification for Cool-Application Filling Com-pounds for Telecommunications Wire and CableD5423 Specification for Forced-Convection LaboratoryOvens for Evaluation of Electrical Insulation3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in these test methods,refer to Terminology
9、D17113.2 Definitions of Terms Specific to This Standard:3.2.1 aging (act of), nexposure of materials to filling orflooding compound at a specified temperature for a specifiedtime.3.2.2 filling compoundany of several materials (seeSpecifications D4731 and D4732) used to fill the air spaces inthe core
10、s of multi-conductor insulated wires and cables for thepurpose of excluding air or moisture or both; especially withregard to telecommunications wire and cable intended fordirect burial.3.2.3 flooding compoundany of several materials (seeSpecification D4730) used to flood wire or cable sheathinterfa
11、ces (for example, the region between core wrap and ashield, between a shield and a jacket, etc.) to eliminate or tominimize normal voids or air spaces in these areas; especiallywith regard to telecommunications wire and cable intended fordirect burial.4. Significance and Use4.1 Cable filling and flo
12、oding compounds are normallysemi-solid at room temperature and fluid in varying degrees atelevated temperatures. They are normally applied in a liquid1These test methods are under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and are the direct responsibilit
13、y ofSubcommittee D09.18 on Solid Insulations, Non-Metallic Shieldings and Coveringsfor Electrical and Telecommunication Wires and Cables. Members of ASTMCommittee D02 on Petroleum Products and Lubricants and ASTM Committee B07on Light Metals and Alloys have contributed to these test methods.Current
14、edition approved Oct. 1, 2009. Published February 2010. Originallyapproved in 1986. Last previous edition approved in 2004 as D4568 99(2004)1.DOI: 10.1520/D4568-99R09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual
15、Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959
16、, United States.state and at an elevated temperature during wire and cablemanufacturing. The completed finished wire or cable is ex-posed to various ambient conditions during its useful life. If notcarefully selected, components of filling or flooding com-pounds have the potential to degrade the mat
17、erials they contact,short term or long term. The following methods are intended tominimize the chances of such problems occurring.4.2 Some of the effects that might occur include, but are notlimited to:4.2.1 Delamination of coated metal shields or screens incompleted wire and cable. Delamination is
18、primarily a functionof the test temperature and the type of laminant used, so testresults are unlikely to vary significantly between filling orflooding compounds of a common family (for example, petro-leum based filling or flooding compounds).4.2.2 Degradation of physical properties of insulation, j
19、ack-ets, core coverings, etc. Likely manifestations of degradationof plastic material include embrittlement of some materials andexcessive softening of other materials.4.3 Since the magnitude of any given effect will vary, sometest procedures will be more critical than others. It is not,therefore, i
20、ntended that every listed procedure be performedwith every compatibility study. Perform procedures to theextent required by product specifications or as agreed uponbetween the producer and the purchaser.5. Apparatus5.1 OvenForced-convection oven, conforming to Specifi-cation D5423, Type II.5.2 Conta
21、inersGlass or other containers of suitable size,shape, and make-up as required to hold the designated speci-mens.5.3 Clamps, or other devices as suitable for holding speci-mens in the oven.5.4 Tensile Strength Testing Apparatus, as specified by thetest requirement.5.5 Mill, Press, and Molding Equipm
22、ent, as needed forpreparation of compression molded specimens as required.5.6 Miscellaneous Lab EquipmentTowels, knives, etc. asrequired for cleaning and cutting specimens.6. Sampling6.1 Ensure that samples of filling and flooding compoundsand the other affected wire and cable materials to be evalua
23、tedare representative of the materials to be used or to be found inthe finished products.COMPATIBILITY EVALUATION BETWEENCOATED METALS AND FILLING OR FLOODINGCOMPOUNDS7. Scope7.1 This test method is specifically for polyolefin coatingson aluminum and steel shielding and armoring material used intele
24、communications wire and cables.8. Specimen Preparation8.1 Cut a specimen of coated metal tape (shielding tape,armor tape, screen tape) 6 in. (150 mm) long for evaluation. Ifa choice of tape widths is possible, select a width narrowenough to fit easily into a container (beaker, graduated cylin-der, e
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD456819992009STANDARDTESTMETHODSFOREVALUATINGCOMPATIBILITYBETWEENCABLEFILLINGANDFLOODINGCOMPOUNDSANDPOLYOLEFINWIREANDCABLEMATERIALS

链接地址:http://www.mydoc123.com/p-517385.html