ASTM D3865-2002 Standard Test Method for Plutonium in Water《水中钚的标准试验方法》.pdf
《ASTM D3865-2002 Standard Test Method for Plutonium in Water《水中钚的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3865-2002 Standard Test Method for Plutonium in Water《水中钚的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3865 02Standard Test Method forPlutonium in Water1This standard is issued under the fixed designation D 3865; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicat
2、es the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of alpha-particle-emitting isotopes of plutonium concentrations over0.01 Bq/L (0.3 pCi/L) in water by means of chemical s
3、epara-tions and alpha pulse-height analysis (alpha-particle spectrom-etry). The isotopes,239Pu,240Pu, and238Pu, are chemicallyseparated from a 1-L water sample by coprecipitation withferric hydroxide, anion exchange and electrodeposition. Thetest method applies to soluble plutonium and to suspendedp
4、articulate matter containing plutonium. In the latter situation,an acid dissolution step is required to assure that all of theplutonium dissolves.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this stan
5、dard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazards aregiven in Section 92. Referenced Documents2.1 ASTM Standards:C 859 Terminology Relating to Nuclear Materials2C 1192 Test Method for Mounting Actinide
6、s for AlphaSpectrometry Using Neodymium Fluoride3C 1284 Practice for Electrodeposition of the Actinides forAlpha Spectrometry2D 1129 Terminology Relating to Water4D 1193 Specification for Reagent Water4D 2777 Practice for Determination of Precision and Bias ofApplicable Methods of Committee D19 on W
7、ater4D 3084 Practice for Alpha Spectrometry of Water5D 3370 Practices for Sampling Water4D 3648 Practices for the Measurement of Radioactivity5D 3856 Guide for Good Laboratory Practices in Laborato-ries Engaged in Sampling and Analysis of Water4D 5847 Practice for Writing Quality Control Specificati
8、onsfor Standard Test Methods for Water Analysis53. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method, referto Terminology D 1129 and Terminology C 859.4. Summary of Test Method4.1 The water sample is acidified and242Pu is added as atracer before any chemical separati
9、ons are performed. Iron isadded to the water as iron (III), and the plutonium is copre-cipitated with the iron as ferric hydroxide. After decantationand centrifugation, the ferric hydroxide precipitate containingthe coprecipitated plutonium is dissolved, and the solution isadjusted to 8 M in HNO3for
10、 anion exchange separation. Whenthe sample fails to dissolve because of the presence ofinsoluble residue, the residue is treated by a rigorous aciddissolution using concentrated nitric, hydrofluoric, and hydro-chloric acids.4.2 After an anion exchange separation, the plutonium iselectrodeposited ont
11、o a stainless steel disk for counting byalpha pulse-height analysis using a silicon surface barrier orion-implanted detector. Table 1 shows the alpha energies of theisotopes of interest in this test method. From the recovery ofthe242Pu tracer, the absolute activities of238Pu and239/240Pucan be calcu
12、lated.5. Significance and Use5.1 This test method was developed to measure plutoniumin environmental waters or waters released to the environment,and to determine whether or not the plutonium concentrationexceeds the maximum amount allowable by regulatory stat-utes.6. Interferences6.1228Th when pres
13、ent at concentrations 100 times orgreater than238Pu has been found to interfere with thedetermination of238Pu. Some228Th comes through thechemical separation procedure and is electrodeposited with the1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsi
14、bility of Subcommittee D19.04 .Current edition approved Feb. 10, 2002. Published May 2002. Originallypublished as D 3865 - 80. Last previous edition D 3865 - 97.2Annual Book of ASTM Standards, Vol 12.01.3Annual Book of ASTM Standards, Vol 15.02.4Annual Book of ASTM Standards, Vol 11.01.5Annual Book
15、of ASTM Standards, Vol 11.02.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.plutonium. If the disk is poorly plated and if the resolution ofthe sample as determined by the alpha spectrometer is notbetter than 60 keV, the238Pu and th
16、e228Th may appear as onepeak; the principal alpha energy of238Pu is 5.50 MeV whilethat of228Th is 5.42 MeV.7. Apparatus7.1 Alpha PulseHeight Analysis System, consisting of asilicon surface barrier, or ion-implanted detector, supportingelectronics, and pulse-height analyzer capable of giving aresolut
17、ion of 50 keV FWHM or better with a sample electrode-posited on a flat, mirror-finished stainless steel disk. Thecounting efficiency of the system should be greater than 15 %and the background in the energy region of each peak shouldbe less than ten counts in 60 000 s.7.2 Electrodeposition Apparatus
18、, consisting ofa0to12V,(0 to 2 A power supply (preferably constant current) and apreferably disposable) electrodeposition cell. The cathode is anapproximately 20-mm diameter stainless steel disk prepolishedto a mirror finish. The anode is an approximately 1-mmdiameter platinum wire with an approxima
19、tely 8-mm diameterloop at the end of the wire parallel to the cathode disk. Coolingof the cell during electrodeposition to at least 50C is recom-mended.7.3 Centrifuge, a 100-mL centrifuge bottle is convenient.7.4 Ion Exchange Column, approximately 13-mm insidediameter and 150 mm long with a 100-mL r
20、eservoir, and eithera fritted glass or Borosilicate glass-wool plug at the bottom.8. Reagents and Materials8.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee onAnal
21、ytical Reagents of theAmerican Chemical Society.6Other grades may be used, provided it is first ascertained thatthe reagent is of sufficiently high purity to permit its usewithout reducing the accuracy of the determination.8.2 Purity of WaterUnless otherwise indicated, referenceto water shall be und
22、erstood to mean reagent water conformingto Specifications D 1193, Type III or better.8.3 Radioactive PurityRadioactive purity shall be suchthat the measured radioactivity of blank samples does notexceed the calculated probable error of the measurement.8.4 Ammonium Hydroxide (sp gr 0.90)Concentrated
23、am-monium hydroxide (NH4OH).8.5 Ammonium Hydroxide Solution (1+9)Mix 1 volumeof concentrated NH4OH (sp gr 0.90) with 9 volumes of water.8.6 Ammonium Hydroxide Solution (1+99)Mix 1 volumeof concentrated NH4OH (sp gr 0.90) with 99 volumes of water.8.7 Ammonium Iodide Solution (145 g/L)Dissolve 14.5 go
24、f NH4I in water and dilute to 100 mL. This solution must beprepared fresh weekly.8.8 Anion Exchange ResinStrongly basic, styrene, quater-nary ammonium salt, 4 % crosslinked, 100 to 200 mesh,chloride form.8.9 Boric Acid (H3BO3)Powdered or crystalline.8.10 Electrolyte, PreadjustedDissolve 132 g of amm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD38652002STANDARDTESTMETHODFORPLUTONIUMINWATER 水中 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-515666.html