ASTM D3616-1995(2014) Standard Test Method for RubberDetermination of Gel Swelling Index and Dilute Solution Viscosity《测定橡胶的凝胶体 膨胀指数及稀释溶液粘度的标准试验方法》.pdf
《ASTM D3616-1995(2014) Standard Test Method for RubberDetermination of Gel Swelling Index and Dilute Solution Viscosity《测定橡胶的凝胶体 膨胀指数及稀释溶液粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3616-1995(2014) Standard Test Method for RubberDetermination of Gel Swelling Index and Dilute Solution Viscosity《测定橡胶的凝胶体 膨胀指数及稀释溶液粘度的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3616 95 (Reapproved 2014)Standard Test Method forRubberDetermination of Gel, Swelling Index, and DiluteSolution Viscosity1This standard is issued under the fixed designation D3616; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the dilutesolution viscosity (DSV), the gel chara
3、cteristics, and theswelling index of raw non-oil-extended and non-pigmentedSBR and NBR.1.2 This test method may be used to determine the DSV andgel characteristics of rubbers other than SBR and NBR,however, solvents other than 2-butanone and toluene may berequired.1.3 This test method is not intende
4、d for the measurement ofmicro-gel.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user
5、of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber and Carbon Black ManufacturingIndus
6、tries2.2 Other Document:3“Reagent Chemicals, American Chemical Society Specifi-cations”3. Summary of Test Method3.1 A weighed sample is allowed to stand 16 to 20 h in asuitable solvent. The sol, or soluble portion, is removed fromthe rubber mixture and the viscosity is determined on thissolution.3.2
7、 A portion of the sol is used for the determination of thedissolved rubber. This is obtained by evaporation of thesolvent.3.3 The swelling index of the gel is determined by compar-ing the dry gel mass to the swollen gel mass.4. Significance and Use4.1 These tests are particularly useful for quality
8、control inthe production of synthetic rubbers.4.2 Percent gel is a measure of the amount of insolublerubber present in the chosen solvent. Gel may be introducedintentionally in some rubbers. Variations from a normal levelindicate changes in the polymerization system.4.3 Swelling index is a measure o
9、f the type of gel. Gel witha low-swelling index is referred to as “hard gel” and usuallyindicates the presence of material that does not break downreadily by milling. A high-swelling index normally indicatesthe presence of a “loose gel” that may be broken down easilyby milling.4.4 In low-gel or gel-
10、free rubbers, the DSV correlatesdirectly with the molecular weight. Since the viscosity ismeasured only on the soluble portion of the rubber, the use ofDSV to predict molecular weight in rubbers having high gelvalues is meaningless.5. Apparatus5.1 Borosilicate Weighing Bottle, 45/12 standard taper,
11、40mm in inside diameter, 100 mm high, with cover.5.2 Screen Rack, consisting of five 300-m (No. 50) circularscreens mounted on a stainless steel tube to fit the weighingbottle (5.1). Borosilicate bottle, cover, and rack will be referredto hereafter as “the unit” (Fig. 1).NOTE 1The unit may be manufa
12、ctured according to the specificationsin Fig. 1.1This test method is under the jurisdiction of ASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee D11.11 on Chemical Analysis.Current edition approved Aug. 1, 2014. Published November 2014. Originallyapproved in 1977. Last pre
13、vious edition approved in 2009 as D3616 95 (2009).DOI: 10.1520/D3616-95R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
14、 ASTM website.3Available from the American Chemical Society, 1155 Sixteenth Street, NW,Washington, DC, 20036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1FIG. 1 Gel Test ApparatusD3616 95 (2014)25.3 Pipet, capable of fitting within
15、 the tube of the screenrack (5.2).5.4 Ostwald Cannon-Fenske Viscometer, size 100.5.5 Constant-Temperature Bath with Stirrer, capable ofoperating at 25 6 0.1C.5.6 Stop Watch or Electric Timer, readable to 0.1 s.5.7 Additional Glassware, sufficient to carry out the proce-dure as written. Class “A” pip
16、ets of 25 and 100-cm3volume aremandatory.5.8 Disposable Aluminum Dishes.5.9 Balance, capable of accurately weighing to 60.1 mg.5.10 Screw-Cap Bottles, 100-cm3minimum capacity, orErlenmeyer flasks, 125-cm3capacity.5.11 Borosilicate Wool or Cotton.6. ReagentsNOTE 2All recognized health and safety prec
17、autions shall be observedin carrying out the procedure as written.6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical
18、 Society,where such specifications are available. Other grades may beused, provided it is ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.6.2 The following solvents are used:6.2.1 2-Butanone (-Methyl Ethyl Ketone), for N
19、BR rubbers,and6.2.2 Toluene, for SBR rubbers.7. Sampling7.1 Select a representative sample of the rubber to be tested.7.2 Do not mill the sample prior to testing except forrubbers in the powdered form (see 8.2).NOTE 3The presence of dusting agents may result in erroneous valuesfor total solids or vi
20、scosity of the solution.8. Procedure8.1 Using clean scissors, cut the sample into strips less than1 mm in thickness and about 5 mm long.8.2 In the case of rubbers in powdered form, the sample maybe massed or compacted by the use of a hand press with platensat 50C. It may then be cut into appropriate
21、 strips. Rubbers thatwill not fall through the screen may be placed on the screenwithout prior treatment.8.3 Weigh 0.39 to 0.41 g of the prepared sample to thenearest 0.1 mg and distribute evenly over the four lowestscreens of the unit (5.2). Place the pieces near the center ofeach screen.8.4 Gently
22、 place the screen rack into the borosilicate weigh-ing bottle (5.1) and deliver 100 cm3of the chosen solvent intothe bottle. Tip the container to assure complete wetting of eachscreen.8.5 Cap the bottle and allow to stand for 16 to 20 h at 25 62C, in the dark.9. Gel9.1 After 16 to 20 h, remove the c
23、ap from the unit, lift thescreen, and examine for visible gel.NOTE 4Some rubbers will not go into solution as readily as others. Itis necessary for the analyst to distinguish between undissolved polymerand true gel.Athinner or more porous sample will aid the solution and anextended standing period,
24、up to 48 h, may be helpful in distinguishing gelfrom true polymer solution. It should be noted, however, that the precisionstatements in Section 13 were obtained using the time interval stated in8.5.9.2 Pipet the liquid from the unit into a screw-cap bottle orErlenmeyer flask by inserting the pipet
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD361619952014STANDARDTESTMETHODFORRUBBERDETERMINATIONOFGELSWELLINGINDEXANDDILUTESOLUTIONVISCOSITY

链接地址:http://www.mydoc123.com/p-515110.html