ASTM D2867-2009 Standard Test Methods for Moisture in Activated Carbon《活性碳湿度的标准试验方法》.pdf
《ASTM D2867-2009 Standard Test Methods for Moisture in Activated Carbon《活性碳湿度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2867-2009 Standard Test Methods for Moisture in Activated Carbon《活性碳湿度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2867 09Standard Test Methods forMoisture in Activated Carbon1This standard is issued under the fixed designation D2867; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthese
2、s indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test methods provide three procedures for thedetermination of the mo
3、isture content of activated carbon. Theprocedures may also be used to dry samples required for othertests. The oven-drying and moisture balance methods are usedwhen water is the only volatile material present and is insignificant quantities, and the activated carbon is not heat-sensitive (some activ
4、ated carbons can ignite spontaneously attemperatures as low as 150C). The xylene-extraction methodis used when a carbon is known or suspected to be heatsensitive or to contain nonwater-miscible organic compoundsinstead of or in addition to water. The oven-drying methoddescribed in these test methods
5、 may be used as the referencefor development of instrumental techniques for moisture de-termination in activated carbon.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of the
6、safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E177 Practice for Use of the
7、 Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Summary of Test Methods3.1 Oven-Drying Test MethodA sample of carbon is putinto a dry, closed capsule (of known weight) and weighedaccurately. The capsule i
8、s opened and placed with the lid in apreheated oven. The sample is dried to constant weight thenremoved from the oven and with the capsule closed, cooled toambient temperature. The closed capsule is weighed againaccurately. The weight loss is expressed as a percentage of theweight of the original sa
9、mple.3.2 Xylene-Extraction Test Method A known, accurateweight of carbon is put into a boiling flask.Aknown volume ofxylene is added to the flask and the flask then connected to awater trap. A hot plate is used to heat the xylene until boiling.The temperature is controlled to allow steady reflux. Re
10、fluxcontinues until no further water can be collected in the trap.The weight of water collected is expressed as a percentage ofthe weight of the original sample.3.3 Moisture Balance Test MethodA sample of activatedcarbon is placed in a moisture balance and the weight measuredaccurately. The sample i
11、s dried to constant weight. The weightloss is expressed as a percentage of the weight of the originalsample.4. Significance and Use4.1 The moisture content of activated carbon is oftenrequired to define and express its properties in relation to thenet weight of the carbon.4.2 The moisture content of
12、 activated carbon packed intypical shipping containers will usually increase during trans-portation and storage. Users of activated carbon in applicationswhere low moisture content is important should be aware ofthis effect.OVEN-DRYING METHOD5. Apparatus5.1 Moisture OvenMost commercial, electrically
13、 heated,forced-circulation drying ovens capable of temperature regu-lation between 145 and 155C may be used.1These test methods are under the jurisdiction of ASTM Committee D28 onActivated Carbon and are the direct responsibility of Subcommittee D28.04 on GasPhase Evaluation Tests.Current edition ap
14、proved Nov. 1, 2009. Published December 2009. Originallyapproved in 1970. Last previous edition approved in 2004 as D2867 04. DOI:10.1520/D2867-09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandard
15、s volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 Capsules with CoversLow-form glass weighingbottles with ground-glass stoppers or seamless metal
16、 boxeswith covers may be used. They should be as shallow aspossible, consistent with convenient handling.5.3 Desiccator.6. Materials6.1 DesiccantAnhydrous calcium chloride or other suit-able desiccant.7. Procedure for Activated Carbon Passing A No. 50Sieve7.1 Dip out with a spoon or spatula from the
17、 sample bottlea 1 to 2-g representative sample. Put this into a predried taredcapsule with lid, close and weigh at once to the nearest 0.5 mg.The depth of the carbon in the capsule must not exceed 1.25cm.7.2 Remove the cover and place the capsule and cover in apreheated forced circulation oven (at 1
18、45 to 155C). Close theoven and dry to constant weight (3 h normally sufficient). Openthe oven and cover the capsules quickly. Cool in a desiccator toambient temperature and weigh.8. Procedure for Activated Carbon Larger Than A No.50 Sieve8.1 Usea5to10-g representative sample and weigh to thenearest
19、2 mg. Complete the determination as described inSection 7.9. Calculation9.1 Calculate the moisture content as follows:Moisture, weight % 5 C 2 D! / C 2 B!# 3 100where:B = weight of capsule with cover, g,C = weight of capsule with cover plus original sample, g,andD = weight of capsule with cover plus
20、 dried sample, g.XYLENEEXTRACTION METHOD10. Apparatus10.1 Boiling FlaskA 300-mL flat-bottom Erlenmeyerflask with ground-glass joints.10.2 CondenserA 300-mm water-cooled condenser of theAllihn type with ground-glass joints.10.3 Drying Tube, containing a suitable desiccant withfiber-glass filter.10.4
21、Water TrapA Bidwell and Sterling 10-mL or a Deanand Stark receiver with ground-glass joints. The water trapshould be clean so that the shape of the meniscus at the end ofthe test is the same as at the beginning.NOTE 1The trap may be coated with a silicone resin to give a uniformmeniscus. To coat the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD28672009STANDARDTESTMETHODSFORMOISTUREINACTIVATEDCARBON 活性碳 湿度 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-513684.html