《ASTM D2685-2011 Standard Test Method for Air and Carbon Tetrafluoride in Sulfur Hexafluoride by Gas Chromatography《用气体色层分离法对六氟化硫中空气和四氟化碳含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2685-2011 Standard Test Method for Air and Carbon Tetrafluoride in Sulfur Hexafluoride by Gas Chromatography《用气体色层分离法对六氟化硫中空气和四氟化碳含量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2685 11Standard Test Method forAir and Carbon Tetrafluoride in Sulfur Hexafluoride by GasChromatography1This standard is issued under the fixed designation D2685; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of air (Note1) and carbon tetrafluoride as impurities in sulfur hexafl
3、uoride.NOTE 1Nitrogen, oxygen, or any of their mixtures is considered to beair. Commercial grade air or nitrogen is used for standardization.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport
4、to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2472 S
5、pecification for Sulfur HexafluorideE260 Practice for Packed Column Gas ChromatographyE355 Practice for Gas Chromatography Terms and Rela-tionships3. Summary of Test Method3.1 Air and carbon tetrafluoride are separated physically bygas chromatography and compared to corresponding compo-nents separat
6、ed under similar conditions from a referencestandard mixture of known composition. The individual com-pounds of air are not separated. The composition of the sampleis calculated from its chromatogram by comparing the area ofthe peak of each component with the area of the peak of thecorresponding com
7、ponent on the reference standard chromato-gram.4. Significance and Use4.1 Air and carbon tetrafluoride (CF4) are two contaminantsof interest in sulfur hexafluoride (SF6). Both of these contami-nants adversely affect the performance of SF6when used as anelectrical insulating gas. Specification for ma
8、ximum levels ofthese contaminants are given in Specification D2472.4.2 Gas chromatography is used to separate these contami-nants from a sample of SF6and to determine their concentra-tion.5. Apparatus5.1 Gas Chromatograph, consisting of a sample inlet sys-tem, adsorption column, flow meter, detector
9、, and data han-dling system. Ensure that the column material of constructionand sample components are compatible. The apparatus mustcompletely separate air, carbon tetrafluoride, and sulfurhexafluoride as indicated by return of the recorded peak to thebase line between each successive peak. Chromato
10、grams mustbe reproducible so that successive runs of a reference standardagree on each component peak area or height within 5 %. Foradditional information on gas chromatography see PracticesE260 and E355.6. Reagents and Materials6.1 Cylinder of Helium Gas.6.2 Reference Standard MixtureA gas mixture
11、that con-tains known percentages of air and carbon tetrafluoride inhelium or air and carbon tetrafluoride in sulfur hexafluoride isrequired. The concentration of a component in the referencesample should not be less than 50 % nor more than 300 % ofthe concentration of the corresponding component in
12、theunknown.7. Calibration and Standardization7.1 Apparatus PreparationPrepare the gas chromato-graph for use as directed by the manufacturer. The followingoperating conditions have been found satisfactory. However,any combination of conditions that result in complete separa-tions as indicated in the
13、 apparatus section will be satisfactory.Carrier gas helium, 40 to 50 mL/minColumn Porapak Q-80/100 mesh or Porapak R 50/80 meshColumn size 6 to 10 Ft (23.5 m) by in. (6.4 mm) nominal1This test method is under the jurisdiction of ASTM Committee D27 ElectricalInsulating Liquids and Gases and is the di
14、rect responsibility of SubcommitteeD27.03 on Analytical Tests.Current edition approved May 1, 2011. Published May 2011. Originallyapproved in 1968. Last previous edition approved in 2003 as D2685 95(2003).DOI: 10.1520/D2685-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orc
15、ontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Column temperature
16、40 to 50CDetector temperature 70 to 80CSample volume 2 to 5 mL approximatelyAttenuation lowest which will keep peaks on a scale may be variedduring runDetector thermal conductivity7.2 Example of Chromatography ConditionsSpecific con-ditions used by one laboratory which produces acceptablechromatogra
17、ms are as follows:Carrier gas helium, 50 mL/minColumn packing Porapak R 50/80 meshColumn size and material 0.25 in. (6.4 mm) nominal ID,10 ft (3.5 m) long, copperColumn temperature 48CDetector thermal conductivityDetector temperature 75CSample volume 5 mL7.3 Reference Standard Introduction and Separ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD26852011STANDARDTESTMETHODFORAIRANDCARBONTETRAFLUORIDEINSULFURHEXAFLUORIDEBYGASCHROMATOGRAPHY 气体

链接地址:http://www.mydoc123.com/p-513315.html