1、Designation: D 2580 06Standard Test Method forPhenols in Water by Gas-Liquid Chromatography1This standard is issued under the fixed designation D 2580; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A nu
2、mber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers a direct aqueous injectionproce
3、dure for the gas-liquid chromatographic determination ofphenols, cresols, and mono- and di-chlorophenols in water.21.2 The precision and bias of the test method has beencalculated from the results of interlaboratory analyses of threemaster solutions, each containing phenol, p-cresol,p-chlorophenol,
4、3,5-dichlorophenol.1.3 The test method may be applied to waste water orconcentrates that contain more than 1 mg/L of phenoliccompounds. Therefore, for a comparison with Test MethodsD 1783, see Appendix X1.1.4 The analyst should recognize that precision statementsprovided in 16.1 and 16.2 may not app
5、ly to waters of othermatrices.1.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are provided forinformation only.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the
6、 user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Note 3.2. Referenced Documents2.1 ASTM Standards:3D 1129 Terminology Relating to WaterD 1193 Specification for Reag
7、ent WaterD 1783 Test Methods for Phenolic Compounds in WaterD 3370 Practices for Sampling Water from Closed ConduitsD 3856 Guide for Good Laboratory Practices in Laborato-ries Engaged in Sampling and Analysis of WaterD 4210 Practice for Intralaboratory Quality Control Proce-dures and a Discussion on
8、 Reporting Low-Level Data4E 260 Practice for Packed Column Gas ChromatographyE 355 Practice for Gas Chromatography Terms and Rela-tionships3. Terminology3.1 DefinitionsDefinitions and terms are presented inPractice E 355 and Terminology D 1129.3.1.1 The following terms used in this test method arede
9、fined in Terminology D 1129 as follows:3.1.2 ghosting a gas-chromatographic interference, show-ing as a peak, which appears at the same elution time as acomponent from previous injection.3.1.3 internal standarda material present in or added tosamples in known amount to serve as a reference measureme
10、nt.3.1.4 noisean extraneous electronic signal that affectsbaseline stability.3.1.5 phenolic compoundshydroxy derivatives of ben-zene and its condensed nuclei.3.1.6 retention timethe time that elapses from the intro-duction of the sample until the component peak maximum isreached.4. Summary of Test M
11、ethod4.1 This test method uses a single gas-liquid chromato-graphic column for the separation of phenolic compounds anda flame-ionization detector for their measurement. The peakarea of each component is measured and compared with that ofa known standard to obtain quantitative results.Adiscussion of
12、gas chromatography is presented in Practice E 260.4.2 In this test method, elution of characteristic phenolsoccurs in the following order: (1) o-chlorophenol, (2) phenoland o-cresol, (3) m- and p-cresol, (4) 2,3-, 2,4-, 2,5- and2,6-dichlorophenols, (5) m- and p-chlorophenol, and (6) 3,4-dichlorophen
13、ol.1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved Aug. 15, 2006. Published August 2006. Originallyapproved in 1967. Last previous edition
14、approved in 2001 as D 2580 94 (2001).2Baker, R. A., “Phenolic Analyses by Direct Aqueous Injection Gas Chroma-tography,” Journal American Water Works Association, Vol 58, No. 6, 1966, pp.751760.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at s
15、erviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2.1 For comparison purposes, see Append
16、ix X1.5. Significance and Use5.1 Phenolic compounds are sometimes found in surfacewaters from natural and industrial sources. Chlorination ofsuch waters may produce odoriferous, objectionable tastingchlorophenols. These compounds may include o-chlorophenol,p-chlorophenol, 2,6-dichlorophenol, and 2,4
17、-dichlorophenol.56. Interferences6.1 Particulate MatterParticulate or suspended mattermay, unless very finely subdivided, plug the needle used forsample injection. Such matter may be removed by centrifuga-tion or filtration, provided it is ascertained that compounds ofinterest are not removed also.
18、A colloid mill may be used, ifnecessary, to prepare a colloidal solution or suspension suitablefor injection. Particulate matter may serve as condensationnuclei for samples; acid treatment may often dissolve suchinterfering solids.6.2 Nonphenolic OrganicsCompounds which have thesame retention value
19、as the phenolic compounds will interferewith the test. Such compounds may be eliminated by a suitablepreliminary separation technique.NOTE 1Refer to Test Methods D 1783.6.3 Alkaline CompoundsUnder strongly alkaline condi-tions, some chlorophenols may form salts which reduce theirvolatility in the te
20、st. Also, some nonphenolic organics, forexample, tar bases, may be more volatile in basic solution.Simple pH adjustment to near neutral or slightly acid willeliminate these interferences.6.4 GhostsElimination of ghosts or memory peaks isrequisite before chromatographic analyses are possible. In this
21、test method, ghosts are minimized or eliminated by injecting 3L of water between all sample injections. This water washusually clears the injection port, column, and detector ofartifacts; however, repeated wash injections may be necessaryto clear the system. The electrometer should be set at maximum
22、sensitivity during the wash injections to facilitate detection ofghosts.NOTE 2Glass injector inserts are recommended. Inserts are easy toclean or replace and minimize clean-up difficulties.6.5 Other InterferencesIt is beyond the scope of this testmethod to describe procedures for eliminating all pos
23、sibleinterferences which might occur, particularly with highlycontaminated industrial waste water.6In addition, the chro-matographic resolution of this test method is insufficient todifferentiate among some isomeric alkyl phenols.7. Apparatus7.1 Chromatographic ColumnsColumns may be pur-chased or pr
24、epared by the analyst. Variations of columnloading, length, diameter, support size, treatment, etc., arepossible. Any column, for example, packed, wide bore (mega-bore) open tubular, analytical capillary, etc., may be used if itis shown to give precision and bias comparable to thoseobtained in the i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD25802006STANDARDTESTMETHODFORPHENOLSINWATERBYGASLIQUIDCHROMATOGRAPHY 色谱 测定 水中 苯酚 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-513114.html