ASTM D511-2014 Standard Test Methods for Calcium and Magnesium In Water《水中钙镁离子的标准试验方法》.pdf
《ASTM D511-2014 Standard Test Methods for Calcium and Magnesium In Water《水中钙镁离子的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D511-2014 Standard Test Methods for Calcium and Magnesium In Water《水中钙镁离子的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D511 14Standard Test Methods forCalcium and Magnesium In Water1This standard is issued under the fixed designation D511; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthese
2、s indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 These test methods cover the determination of calciumand magnesium i
3、n water by complexometric titration andatomic absorption spectrometric procedures. Two test methodsare included, as follows:SectionsTest Method AComplexometric Titration 715Test Method BAtomic Absorption Spectrometric 16251.2 The values stated in SI units are to be regarded asstandard. The values gi
4、ven in parentheses are mathematicalconversion to inch-pound units that are provided for informa-tion only and are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to
5、establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements are given in 12.2.6 and 20.6.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2777
6、Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3370 Practices for Sampling Water from Closed ConduitsD4691 Practice for Measuring Elements in Water by FlameAtomic Absorption SpectrophotometryD4841 Practice for Estimation of Holding Time for Water
7、Samples Containing Organic and Inorganic ConstituentsD5810 Guide for Spiking into Aqueous SamplesD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water Analysis3. Terminology3.1 DefinitionsFor definitions of terms used in these testmethods, refer to Terminology
8、D1129.4. Significance and Use4.1 Calcium and magnesium salts in water are the primarycomponents of water hardness which can cause pipe or tubescaling.5. Purity of Reagents5.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indicated, it is intended that all reagents shallconform
9、to the specifications of the Committee on AnalyticalReagents of the American Chemical Society.3Other gradesmay be used, provided it is first ascertained that the reagent isof sufficiently high purity to permit its use without lesseningthe accuracy of the determination.5.2 Purity of WaterUnless other
10、wise indicated, referencesto water shall be understood to mean reagent water conformingto Specification D1193, Type 1, II, or III water. Type I ispreferred and more commonly used. Type II water wasspecified at the time of round-robin testing of these testmethods.NOTE 1The user must ensure the type o
11、f reagent water is sufficientlyfree of interferences. The water should be analyzed using this test method.6. Sampling6.1 Collect the sample in accordance with Practices D3370.6.2 If total recoverable calcium and magnesium concentra-tions are being determined, acidify the water sample withHNO3(sp gr
12、1.42) to a pH of 2 or less immediately at the timeof collection; normally about 2 mL/L are required. The holdingtime for the samples may be calculated in accordance withPractice D4841.1These test methods are under the jurisdiction of ASTM Committee D19 onWater and are the direct responsibility of Su
13、bcommittee D19.05 on InorganicConstituents in Water.Current edition approved Oct. 1, 2014. Published November 2014. Originallyapproved in 1937. Last previous edition approved in 2009 as D511 09. DOI:10.1520/D0511-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM
14、 Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For Suggestions on the testing of reagent
15、s notlisted by the American Chemical Society, see Annual Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.*A Summary of Changes section appears at the end of this stand
16、ardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1NOTE 2Alternatively, the pH may be adjusted in the laboratory if thesample is returned within 14 days. However, acid must be added at least24 hours before analysis to dissolve any met
17、als that adsorb to the containerwalls. This could reduce hazards of working with acids in the field whenappropriate.6.3 If dissolved calcium and magnesium concentrations arebeing determined, filter the samples through a 0.45-m mem-brane filter and acidify with HNO3(sp gr 1.42) to a pH of 2 orless im
18、mediately at time of collection; normally about 2 mL/Lare required.6.4 A number of sources of calcium contamination havebeen encountered in laboratories.Among the most common areplastic ware, paper towels, and dust. Rinsing plastic ware withsample prior to use, avoiding contact of apparatus with pap
19、ertowels, and keeping exposure to the air to a minimum will limitthe possibility of contamination.TEST METHOD ACOMPLEXOMETRICTITRATION7. Scope7.1 This test method is applicable to most waters in a rangefrom 1 to 1000 mg/L of calcium plus magnesium expressed ascalcium, but may fail in the analysis of
20、 highly colored waters,brines, or waters that contain excessive amounts of metals. Theupper and lower limits may be extended by either dilution oruse of micro apparatus.7.2 Data are not available to determine which matrices wereused to obtain the precision and bias data, and it is theresponsibility
21、of the analyst to determine the acceptability ofthis test method for the matrix being analyzed.8. Summary of Test Method8.1 EDTA (ethylenediamine tetraacetic acid or its salts) isadded to a sample containing calcium and magnesium ionsafter the pH of the solution is adjusted to 10 for the determi-nat
22、ion of calcium and magnesium or from pH 12 to 13 for thedetermination of calcium alone. The EDTA initially complexesthe calcium and then the magnesium. The end point is observedby the use of a suitable indicator. At a pH of 12 to 13magnesium is precipitated. Magnesium is determined by thedifference
23、between an aliquot titrated at pH 10 and one titratedat pH 12 to 13.9. Interferences9.1 EDTA reacts with iron, manganese, copper, zinc, lead,cobalt, nickel, barium, strontium, calcium, magnesium, andseveral other metals. The interference of heavy metals isminimized by the addition of hydroxylamine a
24、nd cyanide,which reduce or complex the metals, or both. Metal concen-trations as high as 5 mg/L of iron, 10 mg/L of manganese, 10mg/L of copper, 10 mg/L of zinc, and 10 mg/L of lead can betolerated when hydroxylamine and cyanide are added.9.2 In the titration of calcium plus magnesium, the higheroxi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD5112014STANDARDTESTMETHODSFORCALCIUMANDMAGNESIUMINWATER 水中 离子 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-511818.html