1、Designation: C991 081C991 15Standard Specification forFlexible Fibrous Glass Insulation for Metal Buildings1This standard is issued under the fixed designation C991; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTE6.1.2 was editorially updated in June 2008.1. Scope1.1 This specification covers the classification, composition, and physical pr
3、operties of flexible fibrous glass insulation for usein metal building roofs and walls.1.2 The basic insulation blanket is designed to be post-processed by a laminating process that applies an adhesive bondedfacing.1.3 The thermal values measured in accordance with this specification for both pre-pr
4、ocessed and post-processed insulation arefor the insulation only and do not include the effects of air-film surface resistance, changes in mean temperature, or compressionof insulation at the framing members of the building, through metal conductance of fasteners and other parallel heat-transfer pat
5、hsdue to design or installation techniques.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.5 This standard does not purport to ad
6、dress all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatoryrequirements prior to use.2. Referenced Documents2.1 ASTM Standards:2C167 Test Met
7、hods for Thickness and Density of Blanket or Batt Thermal InsulationsC168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of theGuarded-Hot-Plate ApparatusC390 Practice for Sampling and Acceptance of Ther
8、mal Insulation LotsC518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter ApparatusC653 Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber InsulationC665 Specification for Mineral-Fiber Blanket Thermal Insulation for
9、 Light Frame Construction and Manufactured HousingC755 Practice for Selection of Water Vapor Retarders for Thermal InsulationC1104/C1104M Test Method for Determining the Water Vapor Sorption of Unfaced Mineral Fiber InsulationC1136 Specification for Flexible, Low Permeance Vapor Retarders for Therma
10、l InsulationC1258 Test Method for Elevated Temperature and Humidity Resistance of Vapor Retarders for InsulationC1304 Test Method for Assessing the Odor Emission of Thermal Insulation MaterialsC1338 Test Method for Determining Fungi Resistance of Insulation Materials and FacingsE84 Test Method for S
11、urface Burning Characteristics of Building MaterialsE136 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750C2.2 Other Referenced Document:CAN/ULC-S102 Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies31 This specification is under t
12、he jurisdiction ofASTM Committee C16 on Thermal Insulation and is the direct responsibility of Subcommittee C16.23 on Blanket and LooseFill Insulation.Current edition approved May 1, 2008April 15, 2015. Published May 2008May 2015. Originally approved in 1983. Last previous edition approved in 200320
13、08 asC991 03.C991 081. DOI: 10.1520/C0991-08E01.10.1520/C0991-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM webs
14、ite.3 Available from Underwriters Laboratories (UL), 333 Pfingsten Rd., Northbrook, IL 60062-2096, http:/.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be tech
15、nically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO
16、Box C700, West Conshohocken, PA 19428-2959. United States13. Terminology3.1 DefinitionsFor definitions of terms relating to insulation, refer to Terminology C168.4. Classification4.1 The flexible fibrous glass insulation is furnished in two types, as follows:4.1.1 Type IGlass processed from the molt
17、en state into fibrous form, bonded with a thermosetting resin, and formed into ablanket or batt.4.1.2 Type IIType I material supplied with a suitable facing adhered to one surface.NOTE 1Facing properties are not part of this specification. The designer is referred to Practice C755 and Specification
18、C1136 for guidance in selectingwater vapor permeance and other physical property requirements.5. Ordering Information5.1 Type I material shall be ordered by specifying thermal resistance value, length, and width.5.2 Type II material shall be ordered by specifying thermal resistance value, type of fa
19、cing, facing permeance, length, width,number of tabs, and tab width.5.3 Certification, when required, shall be in accordance with Section 11.6. Physical Properties6.1 Type 1 Material:6.1.1 Thermal ResistanceThe thermal resistance of the pre-processed insulation shall be determined in accordance with
20、 Guideunfaced insulation shall meet C653. The average R-value from nine randomly selected specimens, three specimens from each ofthree rolls, shall not be less than 103 % of the Rfollowing-value agreed upon by the purchaser and the supplier. Use Test Methodrequirements:C177 or C518 at 75F (23.9C) wi
21、th a minimum temperature difference of 40F (20C) for determining apparentthermal conductivity. Use the full roll method fromTest Method C167 to determine the average thickness for each roll and evaluateat the lesser of measured or label thickness.6.1.1.1 Thermal ResistanceThe average R-value of nine
22、 tests, one each performed on three randomly selected specimens fromeach of three rolls, shall be not less than 103 % of the R-value agreed upon by the purchaser and the supplier.(1) The average thickness of each roll shall be determined byTest Method C167 and the lesser of measured or labeled thick
23、nesstested.(2) The thermal resistance of the pre-processed (unlaminated) insulation shall be determined in accordance with Guide C653,using either Test Method C177 or C518 at a mean temperature of 75F (23.9C) with a minimum temperature difference of 40F(22C) for determining the apparent thermal cond
24、uctivity.NOTE 2See Guide C653. The thermal resistance is a function of temperature. As an option, the thermal resistance may be determined at additionaltemperatures as agreed upon by the purchaser and the manufacturer.6.1.2 Surface Burning CharacteristicsThe surface burning characteristics shall be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC9912015STANDARDSPECIFICATIONFORFLEXIBLEFIBROUSGLASSINSULATIONFORMETALBUILDINGS 金属 建筑物 用挠性 玻璃纤维 绝缘材料

链接地址:http://www.mydoc123.com/p-509084.html