ASTM C716-2006(2015) Standard Specification for Installing Lock-Strip Gaskets and Infill Glazing Materials《锁条衬垫和填充玻璃材料安装的标准规格》.pdf
《ASTM C716-2006(2015) Standard Specification for Installing Lock-Strip Gaskets and Infill Glazing Materials《锁条衬垫和填充玻璃材料安装的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C716-2006(2015) Standard Specification for Installing Lock-Strip Gaskets and Infill Glazing Materials《锁条衬垫和填充玻璃材料安装的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C716 06 (Reapproved 2015)Standard Specification forInstalling Lock-Strip Gaskets and Infill Glazing Materials1This standard is issued under the fixed designation C716; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers installation procedures forlock-strip gaskets that comply with Specification C542
3、and forinfill glazing materials in lockstrip gasket glazing applicationsused in building walls which are not more than 15 from avertical plane. The prime performance considerations areweathertightness against air and water infiltration, and struc-tural integrity under wind loads.1.2 The values state
4、d in SI units are to be regarded asstandard. The values given in parentheses are provided forinformation only.1.3 The committee with jurisdiction over this standard is notaware of any comparable standards published by other orga-nizations.2. Referenced Documents2.1 ASTM Standards:2C542 Specification
5、 for Lock-Strip GasketsC717 Terminology of Building Seals and SealantsC963 Specification for Packaging, Identification, Shipment,and Storage of Lock-Strip GasketsC964 Guide for Lock-Strip Gasket Glazing3. Significance and Use3.1 This specification can be referred to in contract docu-ments as a metho
6、d and workmanship standard for the installa-tion of lock-strip gasket glazing systems. See also relatedstandards (Specifications C542 and C963, Guide C964, andTerminology C717).4. Installation4.1 Inspection of ComponentsBefore installing gaskets,the installer shall check the mounting frames to see t
7、hat theyare within specified dimensional tolerances and not out-of-square or plane, and check all gaskets for type, dimensions, anddefects such as misalignment at molded corners and damagedlips. Installation shall not proceed until corrections have beenmade.4.2 Environmental ConditionsMaximum effici
8、ency andsealing capability of gaskets is achieved in a clean, dry, warmenvironment, with the gasket kept resilient during the entireinstallation process. During cold weather the use of temporaryenclosures around the units to be glazed or paneled willfacilitate temperature control and also aid in kee
9、ping opengasket channels clean and dry.4.3 Preparation and Conditioning of GasketsLock-stripgaskets require conditioning prior to installation in order torestore maximum resiliency and remove deformations afterprolonged storage in a coiled or stressed position. Gaskets shallbe unpacked from their co
10、ntainers and conditioned for 24 h ina temperature not lower than 21.1C (70F) by being placedflat or hung on racks to permit recovery of their originalshapes. Racks shall be free of rough surfaces, projections,sharp edges, and other conditions that could damage thegaskets. When the ambient temperatur
11、e is 10C (50F) orbelow and a heated space is not available, gaskets shall beheated by other means to remove deformations and provide ahigh degree of flexibility and resiliency. This may be done bywarming them in hot water or heated containers. Gaskets shallnot be heated by being draped over heated u
12、nits or placed indirect contact with a flame or fired heating device. Theinstallation of glass, panel, and lock-strip shall be completedwhile the gasket is still warm and pliable and with the gasketchannels clean and dry.4.4 Use of ToolsTo minimize the possibility of damage,sharp or pointed tools or
13、 implements such as screwdrivers orputty knives shall not be used on lock-strip gaskets. Suitablegasket installation tools, such as nonmetallic spatulas andengineered lock-strip insertion devices, are available from thegasket manufacturer.4.5 Use of LubricantsIf necessary a lubricant may beapplied t
14、o the contact surfaces of the gasket to ease theinstallation and help prevent damage to the gasket, glass, orpanel. The lubricant shall be nonstaining, nontoxic,noncorrosive, chemically stable, compatible with all contactcomponents, easily removable from exposed surfaces by dry1This specification is
15、 under the jurisdiction of ASTM Committee C24 onBuilding Seals and Sealantsand is the direct responsibility of Subcommittee C24.73on Compression Seal and Lock Strip Gaskets.Current edition approved Dec. 1, 2015. Published December 2015. Originallyapproved in 1973. Last previous edition approved in 2
16、011 as C716 06 (2011).DOI: 10.1520/C0716-06R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM
17、 International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1wiping or with water, and acceptable to the manufacturer of thesupporting frame, panel, and gasket.4.6 Use of Supplementary Wet SealantsThe use of supple-mentary wet sealants in conjunction with lock-
18、strip gasketinstallations is only required under certain conditions. Such acondition would occur when the outer lip of the gasket extendsover a butt joint in the supporting frame. The void formedbetween the gasket and frame shall be sealed at the time ofinstallation with a wet sealant. However, the
19、sealant may beomitted if the system is designed to drain any water that entersto the exterior, and the omission of a wet sealant is agreeableto the purchaser and seller. Another condition would be at fieldbutt joints in gaskets. Such joints require the use of a sealantinstalled in, rather than on to
20、p of, the joint at the time of thegasket installation. The wet sealant used, as well as the sealantmanufacturers requirements for cleaning and priming thesurfaces to be sealed, shall be compatible with the componentsin contact with it and acceptable to the manufacturers of thecomponents. The use of
21、wet sealants to remedy a defective ordamaged gasket or improperly fabricated supporting frameshall not be permitted, unless agreeable to the purchaser andseller.4.7 Installation of Single-Opening Gasket Systems:4.7.1 H-Type GasketInstall the upper gasket corners first,and then install the lower gask
22、et corners onto the supportingframe. To avoid slippage, engage both horizontal and verticalmembers for about 304.8 mm (1 ft) in both directions from thecorners, and work the gasket until the web is snug against headand jambs and the corners are square. Then work the remainderof the gasket onto the s
23、upporting frame by starting from eachcorner and working towards the center of each side, makingsure the gasket web is firmly seated against the frame and thatthe sealing lips are not curled under, particularly at the corners.Pull each corner of outer flange about 6.4 mm (14 in.) awayfrom the support
24、ing frame with thumb or nonmetallic spatulaand then release to ensure uncurling any corner lips hiddenfrom view.4.7.2 Reglet-Type GasketInsert the upper gasket cornersfirst, and then install the lower gasket corners into the grooveor reglet of the supporting frame, seating them firmly with aresilien
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC71620062015STANDARDSPECIFICATIONFORINSTALLINGLOCKSTRIPGASKETSANDINFILLGLAZINGMATERIALS 衬垫 填充 玻璃

链接地址:http://www.mydoc123.com/p-508096.html