ASTM C618-2012a Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete《混凝土中使用的煤飞灰和未处理的或煅烧的天然火山灰标准规格》.pdf
《ASTM C618-2012a Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete《混凝土中使用的煤飞灰和未处理的或煅烧的天然火山灰标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C618-2012a Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete《混凝土中使用的煤飞灰和未处理的或煅烧的天然火山灰标准规格》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:C61812C61812a Standard Specication for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete 1 This standard is issued under the xed designation C618; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the
2、 year of last revision.Anumber in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval. This standard has been approved for use by agencies of the Department of Defense. 1. Scope* 1.1 This specication covers co
3、al y ash and raw or calcined natural pozzolan for use in concrete where cementitious or pozzolanicaction,orboth,isdesired,orwhereotherpropertiesnormallyattributedtoyashorpozzolansmaybedesired,orwhere both objectives are to be achieved. NOTE 1Finely divided materials may tend to reduce the entrained
4、air content of concrete. Hence, if a y ash or natural pozzolan is added to any concrete for which entrainment of air is specied, provision should be made to ensure that the specied air content is maintained by air content tests and by use of additional air-entraining admixture or use of an air-entra
5、ining admixture in combination with air-entraining hydraulic cement. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 The text of this standard references notes and footnotes, which provide explanatory information.Thes
6、e notes and footnotes (excluding those in tables and gures) shall not be considered as requirements of the standard. 2. Referenced Documents 2.1 ASTM Standards: 2 C125Terminology Relating to Concrete and Concrete Aggregates C311Test Methods for Sampling and Testing Fly Ash or Natural Pozzolans for U
7、se in Portland-Cement Concrete 3. Terminology 3.1 Denitions: 3.1.1 The terms used in this specication are dened in Terminology C125. 3.1.2 y ashthe nely divided residue that results from the combustion of ground or powdered coal and that is transported by ue gasses. NOTE 2This denition of y ash does
8、 not include, among other things, the residue resulting from: (1) the burning of municipal garbage or any other refuse with coal; (2) the injection of lime directly into the boiler for sulfur removal; or (3) the burning of industrial or municipal garbage in incinerators commonly known as incinerator
9、 ash. 4. Classication 4.1 ClassNRaworcalcinednaturalpozzolansthatcomplywiththeapplicablerequirementsfortheclassasgivenherein,such assomediatomaceousearths;opalinechertsandshales;tuffsandvolcanicashesorpumicites,calcinedoruncalcined;andvarious materials requiring calcination to induce satisfactory pr
10、operties, such as some clays and shales. 4.2 Class FFly ash that meets the applicable requirements for this class as given herein. This class of y ash has pozzolanic properties. 4.3 Class CFly ash that meets the applicable requirements for this class as given herein. This class of y ash, in addition
11、 to having pozzolanic properties, also has some cementitious properties. 1 This specication is under the jurisdiction ofASTM Committee C09 on Concrete and ConcreteAggregatesand is the direct responsibility of Subcommittee C09.24 on Supplementary Cementitious Materials. Current edition approved Feb.
12、1, 2012Dec. 15, 2012. Published March 2012January 2013. Originally approved in 1968. Last previous edition approved in 20082012 as C61808a.12. DOI: 10.1520/C061812.10.1520/C061812a. 2 ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatserviceastm.org.ForAnnualB
13、ookofASTMStandards volume information, refer to the standards Document Summary page on the ASTM website. This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because it may not be techni
14、cally possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version of the standard as published by ASTM is to be considered the official document. *A Summary of Changes section appears at the end of this
15、 standard Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States 1NOTE 3Class F y ash is typically produced from burning anthracite or bituminous coal, but may also be produced from subbituminous coal and from lignite. Class C y ash is typic
16、ally produced from burning lignite or subbituminous coal, and may also be produced from anthracite or bituminous coal. Class C y ashes typically have total calcium contents, expressed as calcium oxide (CaO), that are higher than Class F y ashes. 5. Ordering Information 5.1 The purchaser shall specif
17、y any supplementary optional physical requirements. 5.2 The purchaser shall indicate which procedure, A or B, shall be used when specifying requirements for effectiveness in contribution to sulfate resistance under Table 3. 6. Chemical Composition 6.1 Fly ash and natural pozzolans shall conform to t
18、he requirements as to chemical composition prescribed in Table 1. NOTE 4The chemical component determinations and the limits placed on each do not predict the performance of the y ash or natural pozzolan with hydraulic cement in concrete, but collectively help describe composition and uniformity of
19、the material. 7. Physical Properties 7.1 Fly ash and natural pozzolans shall conform to the physical requirements prescribed in Table 2. Supplementary optional physical requirements are shown in Table 3. 8. Methods of Sampling and Testing 8.1 Sample and test the y ash or natural pozzolan in accordan
20、ce with the requirements of Test Methods C311. 8.2 Use cement of the type proposed for use in the work and, if available, from the mill proposed as the source of the cement, in all tests requiring the use of hydraulic cement. TABLE 1 Chemical Requirements Class N F C Silicon dioxide (SiO 2 ) plus al
21、uminum oxide (Al 2 O 3 ) plus iron oxide (Fe 2 O 3 ), min, % 70.0 70.0 50.0 Sulfur trioxide (SO 3 ), max, % 4.0 5.0 5.0 Moisture content, max, % 3.0 3.0 3.0 Loss on ignition, max, % 10.0 6.0 A 6.0 A The use of Class F pozzolan containing up to 12.0 % loss on ignition may be approved by the user if e
22、ither acceptable performance records or laboratory test results are made available. TABLE 2 Physical Requirements Class N F C Fineness: Amount retained when wet-sieved on 45 m (No. 325) sieve, max, % 34 34 34 Strength activity index: A With portland cement, at 7 days, min, percent of control 75 B 75
23、 B 75 B With portland cement, at 28 days, min, percent of control 75 B 75 B 75 B Water requirement, max, percent of control 115 105 105 Soundness: C Autoclave expansion or contraction, max, % 0.8 0.8 0.8 Uniformity requirements: The density and neness of individual samples shall not vary from the av
24、erage established by the ten preceding tests, or by all preceding tests if the number is less than ten, by more than: Density, max variation from average, % 5 5 5 Percent retained on 45-m (No. 325), max variation, percentage points from average 5 5 5 A The strength activity index with portland cemen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC6182012ASTANDARDSPECIFICATIONFORCOALFLYASHANDRAWORCALCINEDNATURALPOZZOLANFORUSEINCONCRETE 混凝土 使用

链接地址:http://www.mydoc123.com/p-507795.html