1、Designation: C 399 98 (Reapproved 2008)e1Standard Practice forUse of Chemical-Resistant Resin Mortars1This standard is issued under the fixed designation C 399; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.e1NOTEA warning note was editorially corrected in July 2008.1. Scope1.1 This practice provides information on the handling andproper use of
3、chemical-resistant resin mortars such as thosecovered in Specification C 395.NOTE 1Resin mortars and grouts are differentiated as follows: resingrouts are applied to the joints, generally14 in. (6 mm) wide, after thebrick or tile are set in place (grouting or tile setters method). Resinmortars are t
4、roweled onto the brick or tile, generally in a18 in. (3 mm)thickness, before the brick are laid in place (buttering or bricklayersmethod). Refer to Practice C 723.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to S
5、I units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and deter
6、mine the applica-bility of regulatory limitations prior to use. Specific precau-tions are given in Sections 5 and 5.2.2. Referenced Documents2.1 ASTM Standards:2C 279 Specification for Chemical-Resistant Masonry UnitsC 305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plast
7、ic ConsistencyC 386 Practice for Use of Chemical-Resistant Sulfur MortarC 395 Specification for Chemical-Resistant Resin MortarsC 410 Specification for Industrial Floor BrickC 723 Practice for Chemical-Resistant Resin Grouts forBrick or TileC 904 Terminology Relating to Chemical-Resistant Non-metall
8、ic MaterialsC 980 Specification for Industrial Chimney Lining Brick3. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, see Terminology C 904.4. Storage4.1 When stated on the package, the manufacturers recom-mendations shall be followed. In all cases, storage shall be ina dr
9、y place with containers tightly closed and away from openflames. Some resins should be stored in a cool place attemperatures as low as 40 to 50F (5 to 10C) to extend theirshelf life. Powder or resin that has become wet or otherwisecontaminated shall not be used.5. Hazards5.1 Consult manufacturers Ma
10、terial Safety Data Sheet forprecautions to be taken when using chemical-resistant resinmortars.5.2 Solvents used for cleaning tools are generally flam-mable. (WarningOpen flames must be kept from the area.“No Smoking” signs should be posted.)6. Equipment6.1 For hand mixing, a shallow mortar box shou
11、ld beprovided. A suggested size is 2 ft2by 4 in. (600 mm2by 100mm) deep.6.2 Equipment for power-mixing ranges from small mixers,such as described in Practice C 305, to simple beaters used onlow-speed motors. A suitable container is a round-bottom panor a 5-gal (20-L) pail, which is commonly availabl
12、e.6.3 Equipment may be required for heating or coolingmaterials as conditions dictate.6.4 All mixing equipment should be clean and dry.7. Mixing7.1 For hand mixing, measure the liquid into the mortar box,then stir the powder in gradually, working out all lumps and airbubbles. Mix with a masons trowe
13、l or other suitable tool.1This practice is under the jurisdiction of ASTM Committee C03 on Chemical-Resistant Nonmetallic Materials and is the direct responsibility of SubcommitteeC03.02 on Monolithics, Grouts and Polymer Concretes.Current edition approved June 1, 2008. Published July 2008. Original
14、ly approvedin 1957. Last previous edition approved in 2003 as C 399 98 (2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Serivce at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page on
15、the ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.2 For power mixing, measure the liquid into the containerand mix in the powder gradually and uniformly.7.3 Mortars shall be mixed in accordance with the manu-facturer
16、s specifications. It is recommended that some meansof measuring be devised so that the batches are uniform.Simple volume measurements may be used, but weighing ispreferred. Consult the manufacturer if variations in proportionsare being considered.7.4 Batch size should be varied according to temperat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC39919982008E1STANDARDPRACTICEFORUSEOFCHEMICALRESISTANTRESINMORTARS 化学 腐蚀 树脂 灰浆 使用 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-466476.html