1、Designation: C 1224 03Standard Specification forReflective Insulation for Building Applications1This standard is issued under the fixed designation C 1224; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the general requirements andphysical properties of reflective insulations for use in buildingapplications.
3、 These insulation materials consist of one or morelow emittance surfaces, such as metallic foil or metallicdeposits, unmounted or mounted on substrates. Reflectiveinsulations derive their thermal performance from surfaceswith an emittance of 0.1 or less, facing enclosed air spaces.1.2 The values sta
4、ted in inch-pound units are to be regardedas the standard. The values given in parentheses are providedfor information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appr
5、o-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 168 Terminology Relating to Thermal InsulationC 177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Me
6、ans ofthe Guarded-Hot-Plate ApparatusC 390 Practice for Sampling and Acceptance of ThermalInsulation LotsC 518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC 727 Practice for Use of Reflective Insulation in BuildingConstructionsC 1258 Test Meth
7、od for Elevated Temperature and Humid-ity Resistance of Vapor Retarders for InsulationC 1338 Test Method for Determining Fungi Resistance ofInsulation Materials and FacingsC 1363 Test Method for the Thermal Performance of Build-ing Assemblies by Means of a Hot Box ApparatusC 1371 Test Method for Det
8、ermination of Emittance ofMaterials Near Room Temperature Using Portable Emis-sometersE 84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE 96 Test Methods for Water Vapor Transmission of Mate-rials2.2 TAPPI Standard:T512 Creasing of Flexible Packaging Material Paper Speci-mens
9、for Testing33. Terminology3.1 DefinitionsTerminology C 168 shall apply to theterms in this specification.3.2 Definitions of Terms Specific to This Standard:3.2.1 reflective insulationthermal insulation consisting ofone or more low emittance surfaces, bounding one or moreenclosed air spaces.4. Orderi
10、ng Information4.1 Prior to purchase, for sampling and acceptance proce-dures, Practice C 390 can be agreed upon between the pur-chaser and the manufacturer.4.2 Specify the required thermal resistance by the directionof the heat flow.4.3 Specify the width, depth, and total area to be insulated.4.4 Sp
11、ecify special markings, if required.5. Materials and Manufacture5.1 Reflective insulation materials shall consist of lowemittance surface(s) with, or without, substrates and adhesivesrequired to meet the specified thermal performance and physi-cal properties.5.2 Multiple layer reflective insulations
12、 shall be designed toattain the intended separation of layers in normal application.Such multiple layer insulation shall form an attachment flangesuitable for stapling, or other means of attachment.5.3 DimensionsInsulation shall be furnished in dimen-sions to fit framing members, at spacings standar
13、d in theconstruction industry, or as specifically agreed upon betweenthe producer and the buyer.1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.21 onReflective Insulation.Current edition approved Oct. 1, 20
14、03. Published October 2003. Originallyapproved in 1993. Last previous edition approved in 2001 as C 122401.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the stand
15、ards Document Summary page onthe ASTM website.3Available from Technical Association of the Pulp and Paper Industry (TAPPI),P.O. Box 105113, Atlanta, GA 30348; 15 Technology Parkway South, Norcross, GA30092.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428
16、-2959, United States.6. Physical Properties Requirements6.1 Low emittance materials shall have a surface with anemittance of 0.1 or less, as determined in accordance with 9.1.6.2 PermeanceIf the reflective insulation is to serve as avapor retarder, the permeance of the material shall not exceedone p
17、erm, as determined in accordance with 9.2.6.3 Surface Burning CharacteristicsBuilding code re-quirements specify flame spread and smoke developmentvalues determined in accordance with 9.3, except as follows:(1) Maximum surface burning characteristics shall not ex-ceed 25 flame spread index and 50 sm
18、oke development indexin either marine or inside plenum applications.(2) Maximum surface burning characteristics shall not ex-ceed 25 flame spread index and 450 smoke development indexin exposed building applications or other installations that mayhave specific requirements not covered by the buildin
19、g code.6.4 Humidity ResistanceThe laminates of the reflectiveinsulation shall be tested in accordance with 9.4. Threespecimens shall be exposed. Shield the test specimens fromcondensate that may drip from the ceiling of the humiditychamber.6.4.1 The specimens shall be evaluated for visible corrosion
20、and delamination. For purposes of corrosion evaluation, theouter 0.25 in. (6.4 mm) perimeter may be disregarded. Notested specimen shall exhibit visible crystalline deposits ex-ceeding 2 % of the test area nor exhibit unaided delaminationof layers.6.5 Adhesive Performance:6.5.1 BleedingAdhesives, wh
21、en used, shall show no signof bleeding when tested in accordance with the test procedurein 9.5.1. Bleeding at cut edges may be disregarded. Bleeding ordelamination, covering over 2 % of the specimen area, shall because for rejection.6.5.2 PliabilitySpecimens tested in accordance with thetest procedu
22、re in 9.5.2 shall not show cracking or delamination.6.6 Fungi ResistanceSpecimens shall not have growthgreater than comparative item when tested in accordance with9.6. Use Interpretation of Results (Paragraph 7.2) of TestMethod C 1338.6.7 Thermal ResistanceDetermine the thermal resistancein accordan
23、ce with procedures in 9.7. The results of theprocedures shall indicate the R-value of the product, in theassembly tested.7. Workmanship, Finish, and Appearance7.1 The insulation shall be manufactured, packaged, andshipped in such a manner that, when received by the customer,it shall be suitable for
24、installation in accordance with PracticeC 727.8. Sampling8.1 Sampling shall be performed in accordance with Prac-tice C 390.9. Test Methods9.1 EmittanceThe emittance of the product shall be testedin accordance with Test Method C 1371.9.2 PermeanceThe permeance of the product shall betested in accord
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12242003STANDARDSPECIFICATIONFORREFLECTIVEINSULATIONFORBUILDINGAPPLICATIONS 建筑物 反射 绝缘材料 标准规范 PDF

链接地址:http://www.mydoc123.com/p-463809.html