ASTM B636 B636M-2015 Standard Test Method for Measurement of Internal Stress of Plated Metallic Coatings with the Spiral Contractometer《采用螺旋收缩仪测量电镀金属镀层内应力的标准试验方法》.pdf
《ASTM B636 B636M-2015 Standard Test Method for Measurement of Internal Stress of Plated Metallic Coatings with the Spiral Contractometer《采用螺旋收缩仪测量电镀金属镀层内应力的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM B636 B636M-2015 Standard Test Method for Measurement of Internal Stress of Plated Metallic Coatings with the Spiral Contractometer《采用螺旋收缩仪测量电镀金属镀层内应力的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B636 84 (Reapproved 2010)B636/B636M 15Standard Test Method forMeasurement of Internal Stress of Plated Metallic Coatingswith the Spiral Contractometer1This standard is issued under the fixed designation B636;B636/B636M; the number immediately following the designation indicates theyear
2、of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the use of the spiral contractom
3、eter for measuring the internal stress of metallic coatings asproduced from plating solutions on a helical cathode. The test method can be used with electrolytic and autocatalytic deposits.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The val
4、ues stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated wi
5、th its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:E177 Practice for Use of the Terms Precision and Bias in ASTM Test Met
6、hodsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method3. Terminology3.1 Definitions:3.1.1 compressive stress ()stress that tends to cause a deposit to expand.3.1.2 internal stressthe net stress that remains in a deposit when it is free from external for
7、ces. The internal stress tends tocompress or stretch the deposits.3.1.3 tensile stress (+)stress that tends to cause a deposit to contract.4. Summary of Test Method4.1 The test method of measuring stress with the spiral contractometer is based on plating on the outside of a helix. The helixis formed
8、 by winding a strip around a cylinder, followed by annealing. In operation, one end of the helix is fixed and the otheris allowed to move as stresses develop. The free end is attached to an indicating needle through gears that magnify the movementof the helix. As the helix is plated, the stress in t
9、he deposit causes the helix to wind more tightly or to unwind, depending onwhether the stress is compressive () or tensile (+). From the amount of needle deflection and other data, the internal stress iscalculated.4.2 With instrument modifications, the movement of the helix can be measured electroni
10、cally instead of mechanically asdescribed in 3.14.1.5. Significance and Use5.1 The spiral contractometer, properly used, will give reproducible results (see 8.59.5) over a wide range of stress values.Internal stress limits with this method can be specified for use by both the purchaser and the produ
11、cer of plated or electroformedparts.1 This test method is under the jurisdiction of ASTM Committee B08 on Metallic and Inorganic Coatings and is the direct responsibility of Subcommittee B08.10 on TestMethods.Current edition approved Nov. 1, 2010Nov. 1, 2015. Published November 2010 December 2015. O
12、riginally approved in 1978. Last previous edition approved in 20062010as B636 84(2006)(2010). e01. DOI: 10.1520/B0636-84R10.10.1520/B0636_B0636M-15.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the p
13、revious version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM
14、 International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.2 Plating with large tensile stresses will reduce the fatigue strength of a product made from high-strength steel. Maximumstress limits can be specified to minimize this. Other properties affected b
15、y stress include corrosion resistance, dimensionalstability, cracking, and peeling.5.3 In control of electroforming solutions, the effects of stress are more widely recognized, and the control of stress is usuallynecessary to obtain a usable electroform. Internal stress limits can be determined and
16、specified for production control.5.4 Internal stress values obtained by the spiral contractometer do not necessarily reflect the internal stress values found on apart plated in the same solution. Internal stress varies with many factors, such as coating thickness, preparation of substrate, currentde
17、nsity, and temperature, as well as the solution composition. Closer correlation is achieved when the test conditions match thoseused to coat the part.6. Apparatus6.1 The spiral contractometer is described by A. Brenner and S. Senderoff.2NOTE 1Spiral contractometers are available from many of the sup
18、pliers of nickel sulfamate.6.2 Helices shall be stopped-off on the inside to prevent plating. Helices are available with or without a permanent inert coatingon the insides (see Appendix X1).6.3 The clamps holding the helix to the contractometer shall be coated with an inert nonconductive coating to
19、prevent theirplating and acting as thieves.6.4 For testing electroplating solutions, anodes are placed equidistant from the helix and symmetrically positioned to produceeven plate distribution. A minimum of four anodes is required. A concentric anode arrangement is preferred.6.5 Laboratory tests on
20、electroplating solutions shall utilize at least 3.7 L of solution. A 4-L beaker with an annular anodearrangement is convenient. Use of this volume or larger will minimize solution changes due to electrolysis during the test.6.6 Laboratory tests on autocatalytic plating solutions are done in a 1-L, t
21、all-form beaker. Obviously, no anodes are used.7. Factors Affecting Accuracy7.1 Variations in the preparation of the helix may cause substantial variations in results.7.1.1 Stop-off material shall be applied properly to the interior of the helix. The stop-off material shall be thin and flexible tope
22、rmit the helix to move freely during the test. A coating weight of less than 50 mg/dm3 mg/in.2 is satisfactory.NOTE 2The inside mustshall be stopped-off with some inert, flexible coating. One acceptable stop-off material is “Microstop.” One part of“Microstop” is diluted with two parts of acetone bef
23、ore use. Any nickel deposited on the inside of the helix will exhibit an opposing effect.7.1.2 Helices that have been permanently coated on the inside with TFE-fluorocarbon may give variable results when testingnear-zero stresses.7.1.3 Cleaning variations and surface preparation of the helix before
24、the test can produce varying results. For example,electrocleaning of the helix shall always be cathodic and controlled with respect to current, time, and temperature.Anodic cleaningat this stage can give wide variations. Abrasive cleaning of the helix and the use of etchants shall be avoided.7.1.4 V
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB636B636M2015STANDARDTESTMETHODFORMEASUREMENTOFINTERNALSTRESSOFPLATEDMETALLICCOATINGSWITHTHESPIRALCONTRACTOMETER

链接地址:http://www.mydoc123.com/p-461827.html