ASTM B556-1990(2007) Standard Guide for Measurement of Thin Chromium Coatings by Spot Test《用点滴试验法测量薄镀铬层厚度》.pdf
《ASTM B556-1990(2007) Standard Guide for Measurement of Thin Chromium Coatings by Spot Test《用点滴试验法测量薄镀铬层厚度》.pdf》由会员分享,可在线阅读,更多相关《ASTM B556-1990(2007) Standard Guide for Measurement of Thin Chromium Coatings by Spot Test《用点滴试验法测量薄镀铬层厚度》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 556 90 (Reapproved 2007)Standard Guide forMeasurement of Thin Chromium Coatings by Spot Test1This standard is issued under the fixed designation B 556; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers the use of the spot test for themeasurement of thicknesses of electrodeposited chromiumcoatings over ni
3、ckel and stainless steel with an accuracy ofabout 620 % (Section 9). It is applicable to thicknesses up to1.2 m.2NOTE 1Although this test can be used for coating thicknesses up to1.2 m, there is evidence that the results obtained by this method are highat thicknesses greater than 0.5 m.3In addition,
4、 for coating thicknessesabove 0.5 m, it is advisable to use a double drop of acid to preventdepletion of the test solution before completion of the test.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of th
5、is standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:4B 504 Test Method for Measurement of Thickness of Me-tallic Coatings by the Coulometric MethodB 568 Test Method for Mea
6、surement of Coating Thicknessby X-Ray SpectrometryB 588 Test Method for Measurement of Thickness of Trans-parent or Opaque Coatings by Double-Beam InterferenceMicroscope Technique3. Summary of Guide3.1 A drop of hydrochloric acid (test solution) is depositedon the surface of the test specimen, and t
7、he time required forthe hydrochloric acid to penetrate through the chromiumcoating (penetration time) is measured. The coating thicknessis proportional to this time.4. Significance and Use4.1 The thickness of a decorative chromium coating is oftencritical to its performance.4.2 This procedure is use
8、ful for an approximate determina-tion when the best possible accuracy is not required. For morereliable determinations, the following methods are available:Methods B 504, B 568, and B 588.4.3 This test assumes that the rate of dissolution of thechromium by the hydrochloric acid under the specified c
9、ondi-tions is always the same.5. Test Solutions5.1 For chromium on nickel the test solution is reagentgrade hydrochloric acid having a specific gravity at 16C of1.180 6 0.002. (This corresponds to 11.5 N 6 0.2 N, whichmay be checked by titration.) For chromium on stainless steelthe test solution is
10、20 g/L of antimony trioxide dissolved inreagent grade hydrochloric acid having a specific gravity at16C of 1.160.NOTE 2As received, reagent grade hydrochloric acid is normallymore concentrated than 11.5 N.6. Preparation of Test Area6.1 The test area must be free of foreign material. Clean byrubbing
11、the test area with a paste of magnesium oxide, rinse it,and dry it with a clean cloth or filter paper. Draw a ring with adiameter of about 6 mm on the test area with melted paraffin orwith a wax pencil.7. Procedure7.1 Let the test specimen, the test solution, and the dropperstand long enough to reac
12、h room temperature, which should bebetween 16 and 25C. Temperatures up to 30C are permis-sible, but the measurements become less reliable at the highertemperatures because of increasing sensitivity to temperature.Thin test specimens should be set on a heavy metal plate toavoid a rapid change in temp
13、erature which could be producedin such specimens by the heat of reaction.7.2 To determine the penetration time, t, deposit a drop(0.03 to 0.05 mL) of the test solution inside the ring of wax,and measure the time between the beginning of the gasformation and the first appearance of nickel. Make thism
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB55619902007STANDARDGUIDEFORMEASUREMENTOFTHINCHROMIUMCOATINGSBYSPOTTEST 点滴 试验 测量 镀铬 厚度 PDF

链接地址:http://www.mydoc123.com/p-461542.html