1、Designation: A 820/A 820M 06Standard Specification forSteel Fibers for Fiber-Reinforced Concrete1This standard is issued under the fixed designationA 820/A 820M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers minimum requirements forsteel fibers intended for use in fiber-reinforced concrete. Fivetypes of st
3、eel fibers for this purpose are defined as pieces ofsmooth or deformed cold-drawn wire; smooth or deformed cutsheet; melt-extracted fibers; mill-cut or modified cold-drawnwire steel fibers that are sufficiently small to be dispersed atrandom in a concrete mixture.1.2 This specification provides for
4、measurement of dimen-sions, tolerances from specified dimensions, and requiredminimum physical properties, and prescribes testing proce-dures to establish conformance to these requirements.1.3 In the case of conflict between a requirement of aproduct specification and a requirement of this specifica
5、tion,the product specification shall prevail. In the case of a conflictbetween a requirement of the product specification or arequirement of this specification and a more stringent require-ment of the purchase order, the purchase order shall prevail.The purchase order requirements shall not take pre
6、cedence ifthey, in any way, violate the requirements of the productspecification or this specification; for example, by the waivingof a test requirement or by making a test requirement lessstringent.1.4 The values stated in either SI units or inch-pound unitsare to be regarded separately as the stan
7、dard. Within the text,the inch-pound units are shown in brackets. The values statedin each system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.2. Referenced Documents2
8、.1 The following documents, of the issue in effect on thedate of material purchase, form a part of this specification tothe extent referenced herein.2.2 ASTM Standards:2A 370 Test Methods and Definitions for Mechanical Testingof Steel ProductsA 700 Practices for Packaging, Marking, and LoadingMethod
9、s for Steel Products for ShipmentC 1116 Specification for Fiber-Reinforced Concrete andShotcrete2.3 ACI Document:544.1R Committee Report on Fiber-Reinforced Concrete32.4 U.S. Military Standard:MIL-STD-129 Marking for Shipment and Storage42.5 U.S. Federal Standard:Fed. Std. No. 123 Marking for Shipme
10、nt (Civil Agencies)43. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 deformed fiber, na fiber that is bent, flattened, orroughened to improve mechanical bond to the concrete matrix.3.1.2 modified fiber, na cold-drawn wire fiber whosecross-section has been changed from circular
11、by shaving thewire.3.1.3 nominal length, nthe length of a deformed fiber,out-to-out, after being deformed.3.1.4 range of equivalent diameter, de-r, na set of limitsplaced on the equivalent diameter by the specifier. See 8.1.6and Note 3.3.2 SymbolsThe following symbols used in this specifi-cation are
12、 defined as follows:A = cross-sectional area, mm2in.2d = diameter, mm in.fu= ultimate tensile strength, MPa psil = length, mm in.l = l/d = aspect ratio3.2.1 The subscript n on dimensional units indicates “nomi-nal” and the subscript e indicates “equivalent.” “Nominal” and1This specification is under
13、 the jurisdiction of ASTM Committee A01 on Steel,Stainless Steel, and Related Alloys and is the direct responsibility of SubcommitteeA01.05 on Steel Reinforcement.Current edition approved March 1, 2006. Published March 2006. Originallyapproved in 1985. Last previous edition approved in 2004 as A 820
14、 04.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Concrete Institute, 38800 Countr
15、y Club Drive,Farmington Hills, MI 48331.4Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS. Or visit: http:/assist.daps.dla.mil/online.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM Int
16、ernational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.“equivalent” dimensions are calculated from other measurabledimensions or average mass weight.4. Classification4.1 Five general types of steel fibers are identified in thisspecification based upon the pro
17、duct or process used as asource of the steel fiber material.4.1.1 Type I, cold-drawn wire.4.1.2 Type II, cut sheet.4.1.3 Type III, melt-extracted.4.1.4 Type IV, mill cut.4.1.5 Type V, modified cold-drawn wire.4.2 Fibers shall be straight or deformed.5. Ordering Information5.1 It shall be the respons
18、ibility of the purchaser to specifyall requirements that are necessary for the product under thisspecification. Such requirements to be considered include, butare not limited to, the following:5.1.1 ASTM designation and year of issue,5.1.2 Quantity in kg pounds or tons,5.1.3 Type or types permissibl
19、e (4.1),5.1.4 Diameter or equivalent diameter (8.1.4), or range ofequivalent diameters (8.1.6),5.1.5 Length or nominal length (3.1.3),5.1.6 Deformations, if required, and5.1.7 Whether certification by the manufacturer is requiredincluding whether a report is to be furnished (Section 11).NOTE 1For in
20、formation on satisfactory sizes and aspect ratios, seeACI 544.1R, and contact the manufacturers regarding availability.6. Materials and Manufacture6.1 The materials and manufacturing methods used shall besuch that the fibers produced conform to the requirements inthis specification.7. Mechanical Pro
21、perties7.1 Tensile Requirements:7.1.1 At least ten individual tensile tests of randomlyselected finished fibers shall be performed for each 4 500 kg 5tons of product. This is an approximate distribution of onefiber tensile test per every 450 kg 0.5 ton of finished product.The average tensile strengt
22、h, fu, of each fiber shall not be lessthan 345 MPa 50 000 psi. The tensile strength of any one ofthe ten specimens shall not be less than 310 MPa 45 000 psi.Where the parent source material consists of sheet or wire,tensile tests by the manufacturer may be performed on largersamples of source materi
23、al. One sample of each differentsource material used shall then be tested for each 4 500 kg 5tons of material. The tensile strength of a single sample ofsource material shall not be less than 345 MPa 50 000 psi.7.1.2 The cross-sectional area used to compute fushall becarried out to five decimal plac
24、es, in units of square millimetressquare inches, and shall be: (1) for drawn wire fibers, Type I,the area calculated from the actual diameter of the parentsource material or finished fiber; (2) for cut sheet fibers, TypeII, the area calculated from the actual thickness and width ofthe parent source
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA820A820M2006STANDARDSPECIFICATIONFORSTEELFIBERSFORFIBERREINFORCEDCONCRETE 钢筋混凝土 纤维 标准规范 PDF

链接地址:http://www.mydoc123.com/p-459667.html