ASTM A610-1979(2004) Standard Test Methods for Sampling and Testing Ferroalloys for Determination of Size《尺寸测量用铁合金的取样和试验的标准试验方法》.pdf
《ASTM A610-1979(2004) Standard Test Methods for Sampling and Testing Ferroalloys for Determination of Size《尺寸测量用铁合金的取样和试验的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM A610-1979(2004) Standard Test Methods for Sampling and Testing Ferroalloys for Determination of Size《尺寸测量用铁合金的取样和试验的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A 610 79 (Reapproved 2004)Standard Test Methods forSampling and Testing Ferroalloys for Determination of Size1This standard is issued under the fixed designation A 610; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover procedures for the samplingand testing of the various ferroalloys for sizing, eit
3、her before orafter shipment from the plants of the manufacturers.1.2 They are designed to give results representative of eachlot that will be comparable with the manufacturers certifiedanalysis for the same lot.1.3 The purchaser may use any sampling procedure hedesires, but the results obtained on s
4、uch samples shall not be abasis for complaint or rejection, unless the procedure followedis of an accuracy equivalent to that prescribed in these testmethods.1.4 The values stated in inch-pound units are to be regardedas the standard. The SI equivalents of inch-pound units may beapproximate.1.5 This
5、 standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents
6、2.1 ASTM Standards:2E 11 Specification for Wire Cloth and Sieves for TestingPurposesE 32 Practices for Sampling Ferroalloys and Steel Additivesfor Determination of Chemical Composition3. Unit Quantities for Sampling and Testing3.1 Each shipment, except as otherwise agreed upon by thepurchaser and th
7、e manufacturer, shall constitute a unit forsampling and testing. It is recommended that shipments of anyalloy exceeding 100 tons (91 000 kg) be divided into smallerlots for sampling according to some plan best adapted to thematerial and conditions, such as each cast, each carload, eachladleful or ea
8、ch binful. The division of samples should be inaccordance with Practices E 32.4. Sampling for Size Analysis4.1 LumpsConformance of lump material to sizing stan-dards normally shall be judged by visual examination. Theinspection judgment shall be made on an increment selected atrandom. Unless otherwi
9、se required, the increment shall be thecontents of a unit container of 2000 lb (910 kg) minimumquantity. When more precise data are required for checking onthe visual examination, a sizing test shall be made on materialfrom a unit container (usually 2000 to 3000 lb (910 to 1360 kg)of alloy) selected
10、 at random.4.2 Crushed or PlatesSampling for conformance ofcrushed or plates material to size requirements shall be inaccordance with Practices E 32 or by alternative methodswhich are demonstrated to yield equivalent results. A represen-tative portion of the lot sample (before any reduction in parti
11、clesize) shall be obtained for screen testing. If necessary, thepercentage of sample taken shall be increased to providesufficient sample in the half reserved for screen testing.4.2.1 Table 1 lists the amount of material that is to be usedfor size analysis.4.2.2 If the top size of the material is 2
12、in. (50.8 mm) orsmaller, the portion for screen test shall be taken from the lotsample by riffling; in larger sizes, by mixing and quartering.Prior to riffling, the starting amount each time must be mixedby coning at least twice.5. Testing for Size Analysis5.1 Samples used for screen testing must be
13、 dry. If there isa question as to whether the material is suitably dry, a criterionof 0.25 % loss in weight at 230F (110C) applies.5.2 With respect to size characteristics, ferroalloys areusually classified as either “lump” or “crushed” sizes. Althoughthe line of demarcation may vary somewhat, the c
14、rushedcategory refers usually to those sizes that have an upper limitof 4 in. (102 mm) or less. The lump sizes involve all of theother categories that are coarser than 4 in. in top size.5.3 LumpsUsing either weight or lineal measurements ascriterion, hand select all pieces from the container that ex
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA61019792004STANDARDTESTMETHODSFORSAMPLINGANDTESTINGFERROALLOYSFORDETERMINATIONOFSIZE 尺寸 测量 铁合金 取样

链接地址:http://www.mydoc123.com/p-458942.html