《ASTM A609 A609M-1991(2007) Standard Practice for Castings Carbon Low-Alloy and Martensitic Stainless Steel Ultrasonic Examination Thereof《碳素钢、低合金钢和马氏体不锈钢铸件及其超声波检验的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM A609 A609M-1991(2007) Standard Practice for Castings Carbon Low-Alloy and Martensitic Stainless Steel Ultrasonic Examination Thereof《碳素钢、低合金钢和马氏体不锈钢铸件及其超声波检验的标准实施规程》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A 609/A 609M 91 (Reapproved 2007)Standard Practice forCastings, Carbon, Low-Alloy, and Martensitic StainlessSteel, Ultrasonic Examination Thereof1This standard is issued under the fixed designationA609/A609M; the number immediately following the designation indicates the yearof original
2、 adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defens
3、e.1. Scope1.1 This practice2covers the standards and procedures forthe pulse-echo ultrasonic examination of heat-treated carbon,low-alloy, and martensitic stainless steel castings by thelongitudinal-beam technique.1.2 This practice is to be used whenever the inquiry,contract, order, or specification
4、 states that castings are to besubjected to ultrasonic examination in accordance with Prac-tice A 609/A 609M.1.3 This practice contains two procedures for ultrasonicinspection of carbon, low-alloy, and martensitic stainless steelcastings; that is, Procedure A and Procedure B. Procedure A isthe origi
5、nal A 609/A 609M practice and requires calibrationusing a series of test blocks containing flat bottomed holes. Italso provides supplementary requirements for angle beamtesting. Procedure B requires calibration using a back wallreflection from a series of solid calibration blocks.NOTE 1Ultrasonic ex
6、amination and radiography are not directlycomparable. This examination technique is intended to complement GuideE94in the detection of discontinuities.1.4 The values stated in either inch-pound units or SI unitsare to be regarded separately as standard. Within the text, theSI units are shown in brac
7、kets. The values stated in eachsystem are not exact equivalents; therefore, each system mustbe used independently of the other. Combining values from thetwo systems may result in nonconformance with this practice.1.5 This standard does not purport to address all of thesafety concerns, if any, associ
8、ated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3A 217/A 217M Specification for Steel Castings, MartensiticS
9、tainless and Alloy, for Pressure-Containing Parts, Suit-able for High-Temperature ServiceE94 Guide for Radiographic ExaminationE 317 Practice for Evaluating Performance Characteristicsof Ultrasonic Pulse-Echo Testing Instruments and Systemswithout the Use of Electronic Measurement Instruments2.2 Oth
10、er Document:SNT-TC-1A Recommended Practice for Non-DestructiveTesting Personnel Qualification and Certification43. Ordering Information3.1 The inquiry and order should specify which procedure isto be used. If a procedure is not specified, ProcedureAshall beused.3.2 Procedure AFlat-Bottomed Hole Cali
11、bration Proce-dure:3.2.1 When this practice is to be applied to an inquiry,contract, or order, the purchaser shall furnish the followinginformation:3.2.1.1 Quality levels for the entire casting or portionsthereof,3.2.1.2 Sections of castings requiring longitudinal-beamexamination,3.2.1.3 Sections of
12、 castings requiring dual element exami-nation,3.2.1.4 Sections of castings requiring supplementary exami-nation, using the angle-beam procedure described in Supple-mentary Requirement S1 in order to achieve more completeexamination, and3.2.1.5 Any requirements additional to the provisions of thispra
13、ctice.1This practice is under the jurisdiction of ASTM Committee A01 on Steel,Stainless Steel and Related Alloys and is the direct responsibility of SubcommitteeA01.18 on Castings.Current edition approved Nov. 1, 2007. Published December 2007. Originallyapproved in 1970. Last previous edition approv
14、ed in 2002 as A 609/A 609M 91(2002).2For ASME Boiler and Pressure Vessel Code applications, see related Specifi-cation SA-609 of Section II of that Code.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMSt
15、andards volume information, refer to the standards Document Summary page onthe ASTM website.4Available fromAmerican Society for Nondestructive Testing (ASNT), P.O. Box28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http:/www.asnt.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C
16、700, West Conshohocken, PA 19428-2959, United States.3.3 Procedure B: Back-Wall Reflection CalibrationProcedureWhen this procedure is to be applied to an inquiry,contract, or order, the purchaser shall designate the qualitylevels for the entire casting or applicable portions.PROCEDURE AFLAT-BOTTOMED
17、 HOLECALIBRATION PROCEDURE4. Apparatus4.1 Electronic Apparatus:4.1.1 An ultrasonic, pulsed, reflection type of instrumentthat is capable of generating, receiving, and amplifying fre-quencies of at least 1 to 5 MHz.4.1.2 The ultrasonic instrument shall provide linear presen-tation (within 65 %) for a
18、t least 75 % of the screen height(sweep line to top of screen). Linearity shall be determined inaccordance with Practice E 317 or equivalent electronic means.4.1.3 The electronic apparatus shall contain a signal attenu-ator or calibrated gain control that shall be accurate over itsuseful range to 61
19、0 % of the nominal attenuation or gain ratioto allow measurement of signals beyond the linear range of theinstrument.4.2 Search Units:4.2.1 Longitudinal Wave, internally grounded, havingato1! in. 13 to 28 mm diameter or 1-in. 25-mm squarepiezo-electric elements. Based on the signals-to-noise ratio o
20、fthe response pattern of the casting, a frequency in the rangefrom 1 to 5 MHz shall be used. The background noise shall notexceed 25 % of the distance amplitude correction curve(DAC). Transducers shall be utilized at their rated frequencies.4.2.2 Dual-Element, 5-MHz, by 1-in. 13 by 25-mm, 12included
21、 angle search units are recommended for sections 1 in.25 mm and under.4.2.3 Other frequencies and sizes of search units may beused for evaluating and pinpointing indications.4.3 Reference Blocks:4.3.1 Reference blocks containing flat-bottom holes shall beused to establish test sensitivity in accorda
22、nce with 8.2.4.3.2 Reference blocks shall be made from cast steels thatgive an acoustic response similar to the castings being exam-ined.4.3.3 The design of reference blocks shall be in accordancewith Fig. 1, and the basic set shall consist of those blocks listedin Table 1. When section thicknesses
23、over 15 in. 380-mm areto be inspected, an additional block of the maximum testthickness shall be made to supplement the basic set.4.3.4 Machined blocks with332-in. 2.4-mm diameter flat-bottom holes at depths from the entry surface of18 in. 3 mm,12 in. 13 mm, or12 t and34 in. 19 mm, or34 t (where t =
24、thickness of the block) shall be used to establish the DAC forthe dual-element search units (see Fig. 2).4.3.5 Each reference block shall be permanently identifiedalong the side of the block indicating the material and the blockidentification.4.4 CouplantA suitable couplant having good wettingcharac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA609A609M19912007STANDARDPRACTICEFORCASTINGSCARBONLOWALLOYANDMARTENSITICSTAINLESSSTEELULTRASONICEXAMINATIONTHEREOF

链接地址:http://www.mydoc123.com/p-458939.html