ASTM D6352-2004(2009) 781 Standard Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700&176 C by Gas Chromatography《用气相色谱法测试174℃-700.pdf
《ASTM D6352-2004(2009) 781 Standard Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700&176 C by Gas Chromatography《用气相色谱法测试174℃-700.pdf》由会员分享,可在线阅读,更多相关《ASTM D6352-2004(2009) 781 Standard Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700&176 C by Gas Chromatography《用气相色谱法测试174℃-700.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6352 04 (Reapproved 2009)An American National StandardStandard Test Method forBoiling Range Distribution of Petroleum Distillates inBoiling Range from 174 to 700C by Gas Chromatography1This standard is issued under the fixed designation D 6352; the number immediately following the des
2、ignation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the d
3、etermination of the boilingrange distribution of petroleum distillate fractions. The testmethod is applicable to petroleum distillate fractions having aninitial boiling point greater than 174C (345F) and a finalboiling point of less than 700C (1292F) (C10 to C90) atatmospheric pressure as measured b
4、y this test method.1.2 The test method is not applicable for the analysis ofpetroleum or petroleum products containing low molecularweight components (for example naphthas, reformates, gaso-lines, crude oils). Materials containing heterogeneous compo-nents (for example alcohols, ethers, acids, or es
5、ters) or residueare not to be analyzed by this test method. See Test MethodsD 3710, D 2887,orD 5307 for possible applicability to analy-sis of these types of materials.1.3 The values stated in SI units are to be regarded asstandard. The values stated in inch-pound units are for infor-mation only and
6、 may be included as parenthetical values.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory
7、 limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D86 Test Method for Distillation of Petroleum Products atAtmospheric PressureD 1160 Test Method for Distillation of Petroleum Productsat Reduced PressureD 2887 Test Method for Boiling Range Distribution ofPetroleum Fractions by Gas
8、 ChromatographyD 2892 Test Method for Distillation of Crude Petroleum(15-Theoretical Plate Column)D 3710 Test Method for Boiling Range Distribution ofGasoline and Gasoline Fractions by Gas ChromatographyD 4626 Practice for Calculation of Gas ChromatographicResponse FactorsD 5307 Test Method for Dete
9、rmination of Boiling RangeDistribution of Crude Petroleum by Gas ChromatographyE 355 Practice for Gas Chromatography Terms and Rela-tionshipsE 594 Practice for Testing Flame Ionization Detectors Usedin Gas or Supercritical Fluid ChromatographyE 1510 Practice for Installing Fused Silica Open TubularC
10、apillary Columns in Gas Chromatographs3. Terminology3.1 DefinitionsThis test method makes reference to manycommon gas chromatographic procedures, terms, and relation-ships. For definitions of these terms used in this test method,refer to Practices E 355, E 594, and E 1510.3.2 Definitions of Terms Sp
11、ecific to This Standard:3.2.1 area slicethe area resulting from the integration ofthe chromatographic detector signal within a specified reten-tion time interval. In area slice mode (see 6.4.2), peak detectionparameters are bypassed and the detector signal integral isrecorded as area slices of conse
12、cutive, fixed duration timeintervals.3.2.2 corrected area slicean area slice corrected for base-line offset by subtraction of the exactly corresponding areaslice in a previously recorded blank (non-sample) analysis.3.2.3 cumulative corrected areathe accumulated sum ofcorrected area slices from the b
13、eginning of the analysis througha given retention time, ignoring any non-sample area (forexample, solvent).3.2.4 final boiling point (FBP)the temperature (corre-sponding to the retention time) at which a cumulative correctedarea count equal to 99.5 % of the total sample area under thechromatogram is
14、 obtained.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.04.0H on Chromatographic Distribution Methods.Current edition approved April 15, 2009. Published July 2009. Originallyapproved in 1998.
15、Last previous edition approved in 2004 as D 6352 041.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyrig
16、ht ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.5 initial boiling point (IBP)the temperature (corre-sponding to the retention time) at which a cumulative correctedarea count equal to 0.5 % of the total sample area under thechromatogram i
17、s obtained.3.2.6 slice ratethe time interval used to integrate thecontinuous (analog) chromatographic detector response duringan analysis. The slice rate is expressed in Hz (for exampleintegrations or slices per second).3.2.7 slice timethe analysis time associated with each areaslice throughout the
18、chromatographic analysis. The slice timeis the time at the end of each contiguous area slice.3.2.8 total sample areathe cumulative corrected area,from the initial area point to the final area point, where thechromatographic signal has returned to baseline after completesample elution.3.3 Abbreviatio
19、nsA common abbreviation of hydrocar-bon compounds is to designate the number of carbon atoms inthe compound. A prefix is used to indicate the carbon chainform, while a subscripted suffix denotes the number of carbonatoms (for example n-C10for normal-decane, i-C14for iso-tetradecane).4. Summary of Te
20、st Method4.1 The boiling range distribution determination by distilla-tion is simulated by the use of gas chromatography. Anon-polar open tubular (capillary) gas chromatographic col-umn is used to elute the hydrocarbon components of the samplein order of increasing boiling point.4.2 A sample aliquot
21、 is diluted with a viscosity reducingsolvent and introduced into the chromatographic system.Sample vaporization is provided by separate heating of thepoint of injection or in conjunction with column oven heating.4.3 The column oven temperature is raised at a specifiedlinear rate to affect separation
22、 of the hydrocarbon componentsin order of increasing boiling point. The elution of samplecomponents is quantitatively determined using a flame ioniza-tion detector. The detector signal is recorded as area slices forconsecutive retention time intervals during the analysis.4.4 Retention times of known
23、 normal paraffin hydrocarbons,spanning the scope of the test method, are determined andcorrelated to their boiling point temperatures. The normalizedcumulative corrected sample areas for each consecutive re-corded time interval are used to calculate the boiling rangedistribution. The boiling point t
24、emperature at each reportedpercent off increment is calculated from the retention timecalibration.5. Significance and Use5.1 The boiling range distribution of medium and heavypetroleum distillate fractions provides an insight into thecomposition of feed stocks and products related to petroleumrefini
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD635220042009781STANDARDTESTMETHODFORBOILINGRANGEDISTRIBUTIONOFPETROLEUMDISTILLATESINBOILINGRANGEFROM174TO700176CBYGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-522255.html