ARMY UFGS-01 45 35-2008 SPECIAL INSPECTION FOR SEISMIC-RESISTING SYSTEMS《抗震系统的特殊检验》.pdf
《ARMY UFGS-01 45 35-2008 SPECIAL INSPECTION FOR SEISMIC-RESISTING SYSTEMS《抗震系统的特殊检验》.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-01 45 35-2008 SPECIAL INSPECTION FOR SEISMIC-RESISTING SYSTEMS《抗震系统的特殊检验》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-01 45 35 (August 2008)-Preparing Activity: USACE SupersedingUFGS-01 45 35 (October 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2008*SECTION TABLE OF CONTENTSDIVISION 01 - GENERAL REQUIREMENTSSECTION 01 45 35SPECIAL
2、 INSPECTION FOR SEISMIC-RESISTING SYSTEMS08/08PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.2.1 Continuous Special Inspection1.2.2 Perodic Special Inspection1.3 SUBMITTALS1.4 QUALITY ASSURANCE PLAN1.5 SPECIAL INSPECTORPART 2 PRODUCTSPART 3 EXECUTION3.1 PERFORMANCE OF INSPECTIONS3.1.1 Piers Pil
3、es Caissons3.1.2 Reinforcing Steel3.1.3 Structural Concrete3.1.4 Prestressed Concrete3.1.5 Structural Masonry3.1.6 Structural Steel3.1.7 Structural Wood3.1.8 Cold-Formed Steel Framing3.1.9 Architectural Components3.1.10 Mechanical and Electrical Components3.1.11 Seismic Isolation System3.1.12 Energy
4、 Dissipation System3.2 TESTING3.3 REPORTING AND COMPLIANCE PROCEDURES- End of Section Table of Contents -SECTION 01 45 35 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-01 45 35 (August 2008)-Preparing Acti
5、vity: USACE SupersedingUFGS-01 45 35 (October 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2008*SECTION 01 45 35SPECIAL INSPECTION FOR SEISMIC-RESISTING SYSTEMS08/08*NOTE: This guide specification covers the requirements for special inspection and test
6、ing for seismic-resisting systems when required by Chapter 2 of FEMA 450 NEHRP RECOMMENDED PROVISIONS FOR SEISMIC REGULATIONS FOR NEW BUILDINGS AND OTHER STRUCTURES. This specification will apply only to buildings.Edit this guide specification for project specific requirements by adding, deleting, o
7、r revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to th
8、e technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*NOTE: This guide specification will be
9、 applicable to both new buildings designed according to UFC 3-310-04 SEISMIC DESIGN FOR BUILDINGS, and existing building seismic rehabilitation designs.In addition to the special inspection and testing specified requirements, the structural designer of the seismic-resisting structural systems must p
10、erform “structural observations“ during construction when required by paragraph 2.5 of FEMA 450. All observed deficiencies will be immediately SECTION 01 45 35 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-reported to the Contracting Officer.
11、 The structural designer performing these observations will be a representative of the Engineer of Record (EOR) for the building being constructed. The EOR will be the Chief of Engineering of the USACE office performing the design for in-house designs and will be the principal of the firm in charge
12、of the design for Architect-Engineer (A-E) designs.The requirements for special inspection, the special inspector, and related testing will be used only where required by Chapter 2 of FEMA 450. When special inspection is required, FEMA 450 also requires that for certain buildings a quality assurance
13、 plan be developed.The extent of the qualifications of the Contractor and subContractors can vary considerably, hence the extent of the quality control can vary considerably. The quality assurance plan, therefore, is an opportunity to identify those areas of special concern that must be addressed du
14、ring the construction process. Those areas include, but are not limited to, types of testing, frequency of testing, types of inspections and frequency of inspections.*1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications a
15、re referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article
16、. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a p
17、art of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ACI INTERNATIONAL (ACI)ACI 318 (2008; Errata 2008) Building Code Requirements for Structural Concrete and SECTION 01 45 35 Page 3Provided by IHSNot for ResaleNo reproduc
18、tion or networking permitted without license from IHS-,-,-CommentaryACI 318M (2005) Metric Building Code Requirements for Structural Concrete and CommentaryACI 530.1 (2005) Specification for Masonry StructuresAMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)AISC 341 (2005; Supp 2001) Seismic Provision
19、s for Structural Steel BuildingsAISC 360 (2005) Specification for Structural Steel Buildings, with CommentaryASTM INTERNATIONAL (ASTM)ASTM A 435/A 435M (1990; R 2007) Standard Specification for Straight-Beam Ultrasonic Examination of Steel PlatesASTM A 615/A 615M (2008) Standard Specification for De
20、formed and Plain Carbon-Steel Bars for Concrete ReinforcementASTM A 898/A 898M (2007) Standard Specification for Straight Beam Ultrasonic Examination of Rolled Steel Structural ShapesU.S. FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA)FEMA 450 (2003) NEHRP Recommended Provisions for Seismic Regulations f
21、or New Buildings and Other Structures1.2 SYSTEM DESCRIPTIONPerform the Special Inspection for seismic-resisting system components as specified. Special Inspector personnel shall be in addition to the quality control inspections and inspectors required elsewhere in this section.1.2.1 Continuous Speci
22、al InspectionContinuous special inspection is the full time observation of the work by the Special Inspector present in the work area whenever work is being performed. Perform continuous special inspection where specified for items as shown on the drawings.1.2.2 Perodic Special InspectionPerodic spe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS0145352008SPECIALINSPECTIONFORSEISMICRESISTINGSYSTEMS 抗震 系统 特殊 检验 PDF

链接地址:http://www.mydoc123.com/p-449508.html