ARMY MIL-PRF-62071C-1995 POWER SUPPLY HIGH VOLTAGE SOLID STATE 24 VOLTS DIRECT CURRENT《24伏高压直流固态电源》.pdf
《ARMY MIL-PRF-62071C-1995 POWER SUPPLY HIGH VOLTAGE SOLID STATE 24 VOLTS DIRECT CURRENT《24伏高压直流固态电源》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-62071C-1995 POWER SUPPLY HIGH VOLTAGE SOLID STATE 24 VOLTS DIRECT CURRENT《24伏高压直流固态电源》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-PRF-62071 C(AT) - SUPERSEDING MIL-P-62071B (AT) 13 November 1986 19 April 1977 MIL-P42071/1C(AT) PERFORMANCE SPECIFICATION POWER SUPPLY: HIGH VOLTAGE, SOLID STATE, 24 VOLTS, DIRECT CURRENT This specification is approved for use by the U.S. Army Tank-automotive and Armaments Command, Department o
2、f the Army, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Smpe. This specification covers one type of power supply for conversion of low voltage direct current (dc) electrical energy into high voltage dc electrical energy (see 6.1). 2, APPLICABLE
3、 DOCUMENTS 2.1 Genetal. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to en
4、sure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in section 3 and section 4 of this specification, whether or not they are listed. Beneficial comments (recommendations, additions, deletions) and any pertinent data which m
5、ay be of use in improving this document should be addressed to: U.S. Army Tank-automotive and Armaments Command, ATTN: AMSTA-TR-EBLUE, Warren, MI 48397-5000 by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC N/A FSC 2590
6、 IJTTON STKEIYUBJEA. Approved for public release; distribution is unlimited. Licensed by Information Handling Services MIL-PRF-b207LC 999990b 2033956 O96 = MIL-PRF-6207 1 C (AT) 2.2 Government. . The following specifications, standards, . 2.2.1 and Lead Alloy. - Enamel, Alkyd, Gloss (For Exterior an
7、d Interior Surfaces). STANDARDS FEDERAL FED-STD-595 - Colors. DEPARTMENT OF DEFENSE MIL-STD-193 MIL-STD-454 MIL-STD-461 MIL-STD-462 MIL-STD-810 MIL-STD-889 MIL-STD-1184 MIL-STD-1275 MS27190 - Painting Procedures and Marking for Vehicles, Construction Equipment and Material Handling Equipment. - Stan
8、dard General Requirements for Electronic Equipment. - Electromagnetic Emission and Susceptibility Requirements - Electromagnetic Interference Characteristics, Measurement - Environmental Test Methods and Engineering Guidelines. - Dissimilar Metals. - Electrical Components for Automotive Vehicles; -
9、Characteristics of 28 Volt DC Electrical Systems in - Connector, Receptacle, Electrical-High Voltage, for the Control of Electromagnetic Intederence. of. Waterproofness Tests. Military Vehicles. Waterproof. 2 Licensed by Information Handling Services(Unless otherwise indicated, copies of the above s
10、pecifications, standards, and handbooks are available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 191 11-5094.) -. 2.3 Non-Govv . The following document forms a part of this document to the extent specified herein. Unless otherwise specified, the i
11、ssues of the documents which are DoD adopted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issue of the documents cited in the solicitation (see 6.2). AMERICAN SOCIETY FOR TESTING AND MATERI
12、ALS (ASTM) ASTM B117 ASTM B633 - Standard Test Method of Salt Spray (Fog) Testing. - Electrodeposited Coating of Zinc or Iron and Steel, Specification For. (Application for copies should be addressed to American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103.) AMERICAN N
13、ATIONAL STANDARD INSTITUTE (ANSI) ANSI S3.6 ANSUASQC 21.4 - Audiometers, Specification for. - Sampling Procedures and Tables for Inspection by Attributes. (Application for copies should be addressed to American National Standard Institute, Inc., 11 W. 42nd Street, 13th Floor, New York, NY 10036.) AC
14、OUSTICAL SOCIETY OF AMERICA (ASA) ASA 47 - Sound Level Meters. (Application for copies of Acoustical Society of America publications should be addressed to the acoustical Society of America, 335 East 45th Street, New York, NY 10017.) 2.4 v. In the event of a conflict between the text of this documen
15、t and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3 Licensed by Information Handling ServicesMIL-PRF-62071C rn 9799906 2033958 b9 rn 3. REQUIREMEN
16、TS 3.1 Ekskxh the corresponding output voltages shall be recorded to determine compliance with table I and 3.4.1.4. The load shall then be reduced to 80 megohms, and the input voltage shall be varied; the corresponding output voltages shall be recorded to determine compliance with 3.4.1.4 and table
17、I. 4.7.4.1.5 nytput vol- . To determine conformance to 3.4.1.5, The power supply shall be tested as follows: Connect the power supply to a 160-megohms divided load resistor and microammeter. Place the microammeter in the grounded side of the line. A 5-minute warm up period shall precede the test. Us
18、e an oscilloscope to measure the voltage across the 50,000- ohm portion of the load resistor adjacent to the microammeter. Convert the microammeter readings to (average) dc output voltage. Obtain the peak alternating current (dc) voltage readings from the oscilloscope. Then calculate the voltage var
19、iation as peak ac voltage divided by (average) dc output voltage to determine compliance with 3.4.1.5. 15 Licensed by Information Handling ServicesMIL-PW-6207 1 C (AT) 4.7.4.1.6 - . To determine conformance to 3.4.1.6 and MIL-STD-1275, the power supply with a load of 160 megohms shall be subject to
20、an input voltage of 30 V with a superimposed square wave impulse of 70 V peak (100 V peak total) of 50 f 5 ms duration and a repetition rate of 6 f 0.5 seconds for a period of 8 hours. After the test, the power supply shall be tested as specified in 4.7.4.1.4 to determine compliance with 3.4.1.4. 4.
21、7.4.1.7 To determine conformance to 3.4.1.7, an ammeter shall be used to determine the input current. 4.7.4.1.8 * . To determine conformance to 3.4.1.8, the source polarity shall be reversed, and voltage from O to 40 V dc shall be applied. A multirange ammeter in the input circuit shall be used to i
22、ndicate the current magnitude and its direction. 4.7.4.1.9 * . To determine conformance to 3.4.1.9, the power supply shall be operated with no load for 5 minutes and tested in accordance with 4.7.4.1.4. 4.7.4.1.10 . To determine conformance to 3.4.1.10, the output of the power supply shall be short-
23、circuited with the power supply operating into a 160 megohm load within the functional voltage range (18 to 30 V). Subsequent to the test the power supply shall be subjected to the test specified in 3.7.4.1.4. 4.7.4.1.11 Endurance. To determine conformance to 3.4.1.11, the power supply shall be subj
24、ected to continuous operation with 26 V input and a 160 megohm load resistor for 1000 hours. At intervals of 50 hours, the specimen shall be tested as specified in 4.7.4.1.4 to determine compliance with 3.4.1.4. Upon completion of the endurance test, the power supply shall be tested as specified in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF62071C1995POWERSUPPLYHIGHVOLTAGESOLIDSTATE24VOLTSDIRECTCURRENT24 高压 直流 固态 电源 PDF

链接地址:http://www.mydoc123.com/p-447541.html