ARMY MIL-PRF-62061 D-2009 GENERATOR ENGINE ACCESSORY 28 VOLT DC RATED OUTPUT 300 AMPERE《28伏直流 额定输出为300安的引擎附件 发电机》.pdf
《ARMY MIL-PRF-62061 D-2009 GENERATOR ENGINE ACCESSORY 28 VOLT DC RATED OUTPUT 300 AMPERE《28伏直流 额定输出为300安的引擎附件 发电机》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-62061 D-2009 GENERATOR ENGINE ACCESSORY 28 VOLT DC RATED OUTPUT 300 AMPERE《28伏直流 额定输出为300安的引擎附件 发电机》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、 Comments, suggestions, or questions on this document should be addressed to U.S. Army Tank-automotive and Armaments Command, ATTN: RDTA-EN/STND/TRANS MS#268, 6501 E. 11 Mile Road, Warren, MI 48397-5000 or emailed to DAMI_STANDARDIZATIONconus.army.mil. Since contact information can change, you may w
2、ant to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 2920 INCH-POUND MIL-PRF-62061D 14 August 2009 SUPERSEDING MIL-PRF-62061C 20 December 1997 PERFORMANCE SPECIFICATION GENERATOR, ENGINE ACCESSORY: 28 VOLT DC, RATED OUTPUT
3、 300 AMPERE This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers a 28 volt (V) direct current (dc), blower-cooled generator with rated output of 300 amperes (A) (see 6.1). 1.2 Classification. The generators
4、 are classified based on differences in their configurations as follows: Configuration A - Generator with mechanically driven blower Configuration B - Generator with built in electrically driven blower Configuration C - Generator with mounted electrically driven blower Configuration D - Generator -
5、Air intake Assembly 1.3 Part or Identification Number (PIN). The PIN to be used for generators acquired to this specification are created as follows (see 3.5.6): M62061 - X Type (see 1.2): A - Configuration A B - Configuration B C - Configuration C D - Configuration D Specification number Provided b
6、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-62061D 2 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sectio
7、ns of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, wh
8、ether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
9、 solicitation or contract. COMMERCIAL ITEM DESCRIPTIONS A-A-50271 - Plates, Identification DEPARTMENT OF DEFENSE STANDARDS MIL-STD-461 - Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment (See 4.3) (Copies of these documents are available online
10、at http:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of
11、this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. US ARMY TACOM DRAWINGS 8717421 - Generator, Engine Accessory (interface) 10889713 - Generator, Engine Accessory (interface) 10889998 - Generator, E
12、ngine Accessory (interface) 10914831 - Generator, Engine Accessory (M107) (interface) (Copies of this drawing are available from the U.S. Army Tank-automotive and Armaments Command, ATTN: RDTA-EN/STND/TRANS MS #268, 6501 E. 11 Mile Road, Warren, MI 48397-5000, or email DAMI_STANDARDIZATIONconus.army
13、.mil.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-62061D 3 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents ar
14、e those cited in the solicitation or contract. ASTM INTERNATIONAL ASTM B117 - Standard Practice for Operating Salt Spray (Fog) Apparatus (DoD Adopted) ASTM G21 - Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi (DoD Adopted) (Copies of these documents are availa
15、ble from www.astm.org or ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.) 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document ta
16、kes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.1.1. 3.2 Design, mate
17、rials, and manufacturing processes. Unless otherwise specified, the design, materials, and manufacturing process selection shall be the prerogative of the contractor as long as all articles submitted to the government fully meet the operating, interface, ownership and support, and operating environm
18、ent requirements specified. 3.2.1 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible, provided that the material meets or exceeds the operational and maintenance requirements, and pr
19、omotes economically advantageous life cycle costs. 3.3 Operating requirements. 3.3.1 Polarity. The generator shall be designed to operate within a negatively grounded electrical circuit (see 4.5.1). 3.3.2 Output. The generator shall meet the performance requirements specified in figure 1 (see 4.5.2)
20、. 3.3.2.1 Output, performance checkpoint (heat stabilized). The generator shall subsequently meet the requirements at the one stabilized performance checkpoint indicated in figure 1 (see 4.5.2.1). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P
21、RF-62061D 4 RPM AMP (min) Comments 1500 0 Cut-in-speed 1625 100 1750 200 1900 300 Min. speed at rated output 2000 380 Performance checkpoint 2500 425 3000 425 4000 425 5000 425 6000 415 8000 360 Max. operating speed 10000 - Overspeed NOTE: Generator performance requirements shown above shall be obta
22、ined when generator is assembled and tested with blower and adapter. FIGURE 1. Performance curve. 1000 2000 3000 4000 5000 6000 7000 8000 900060050040030020010000P E R F OR M AN C EI N T H I S A R E AN OT AC C E PT AB L EG E N E R A T O R SP E E D - R P MGENERATOROUTPUT-AMPERESProvided by IHSNot for
23、 ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-62061D 5 3.3.2.2 Speeds and current. The generator shall meet the current and voltage requirements at less than the maximum speeds specified below (see 4.5.2.2): a) Cut-in speed at 28.5 0.1 V at 0 A load (maximum spe
24、ed allowable: 1425 rpm) b) Minimum speed at 100 A at 28.5 0.1 V (maximum speed allowable: 1550 rpm) c) Minimum speed at 300 A at 28.5 0.1 V (maximum speed allowable: 1825 rpm) 3.3.3 Interpole voltage. The voltage measured between the paralleling terminal (D) and the negative terminal (E) shall confo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF62061D2009GENERATORENGINEACCESSORY28VOLTDCRATEDOUTPUT300AMPERE28 直流 额定 输出 300 引擎 附件 发电机 PDF

链接地址:http://www.mydoc123.com/p-447539.html