1、R b 1 MIL-PRF-44485 9999906 2026937 TLb I INCH-POUND I MIL- PRF - 444 8 5 4 November 1996 PERFORMANCE SPECIFICATION BURNER UNIT, FIELD FEEDING This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers a burner u
2、nit (stove) for use as the heat source for military field feeding equipment and field sanitation equipment (see 6.1). 2. APPLICABLE DOCUMENTS (None) 3. REQUIREMENTS 3.1 First article. When specified (see 6.21, a sample shall be subjected to first article inspection as specified in 4.2. Beneficial co
3、mments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: U.S. Army Natick Research, Development and Engineering Center, ATTN: SSCNC-WEF, Natick, MA 01760-5018 by using the Standardization Document Improvement Proposa
4、l (DD FORM 1426) appearing at the end of this document or by letter. AMSC N/A FSC 7310 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- I MIL-PRF-44485 9997706 202bLB 752 MIL-PRF-44485 3.2 Operating reauirements. Burner units (stoves) shall satisfy t
5、he following functional, operational and performance requirements. 3.2.1 Heat outDut. The stove shall have an infinitely adjustable firing rate. The minimum firing rate shall be not greater than 1.2 lbs-fuel/hour, and the maximum firing rate shall be not less than 2.8 lbs-fuel/hour. Heat output drif
6、t shall be not greater than +lo% during 3 hours of operation at any heat output setting. 3.2.2 Heat transfer. The stove shall be capable of increasing the temperature of 80 lbs of water 100F in less than 35 minutes. 3.2.3 Compatibility. The stove shall be compatible with current Army field feeding e
7、quipment used in the Mobile Kitchen Trailer (MKT), NSN 7360-01-155-6020 and the Kitchen, Company Level Field Feeding (KCLFF), NSN 7360-01-200-9828, Modular Field Kitchen (MFK), NSN 7360-01-276-9817, and the Field Sanitation Center (FSC), NSN 7360-01-277-2558. The stove shall operate reliably in the
8、burner rack (NSN 7360-01-250-3649) and base rack (NSN 7360-01-250-3652) with various appliances mounted, heater tank assembly (NSN 7360-01-248-6041), and model M59 field range outfit (NSN 7360-00-028-2153) in both upper and lower positions. Use of the stove shall require no modifications to field fe
9、eding equipment with the exception of an access hole for the electrical receptacles (see figures 1 through 8 for reference purposes only). 3.2.4 Fuel comDatibilitv. The stove shall be capable of operating on JP-8. 3.2.5 Fuel caDacity. The stove shall be capable of operating continuously, using only
10、its internal fuel tank, at the highest heat setting, without refueling or shutting down, for not less than four hours. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-44485 M 9999906 2026939 899 MIL-PRF-44485 3.2.6 Weiaht. The total weight
11、of the fully fueled stove shall be not greater than 68 pounds. 3.2.7 GrasDing handle. A non-slip handle or grasp surface (e.g. grooved, knurled, or frictional) shall be located on the front of the stove to aid in removal from all cooking appliances. 3.2.8 Carrvincr handles. The stove shall be equipp
12、ed with handles or grasp areas to allow two persons to lift and carry the unit. Handle length shall be a minimum of 11 inches to allow each person to use both hands to carry the stove. 3.2.9 Voltacr _e. The stove shall operate only within the range of 22.0 to 29.5 volts DC. 3.2.10 Power consumDtion.
13、 The stove power consumption shall be minimized to allow operation from a rechargeable battery pack. Cumulative power consumption shall not be greater than 275 watt-hours to perform a cooking mission that includes refueling from an empty tank and a 3 hour cooking cycle at a firing rate that consumes
14、 the maximum amount of power. Maximum current draw under all circumstances shall not exceed 5 amps. 3.2.11 Reversed D olaritv. The stove shall be designed for protection against a reversed polarity power supply. 3.2.12 Burner control. The stove shall be equipped with a burner control that shall be u
15、sed to initiate and stop combustion. 3.2.13 Refuel control. The stove shall be equipped with a refuel control that initiates the automatic refueling process. For safety purposes, the refuel control shall be designed such that the stove cannot refuel while the burner is operational. 3.2.14 Heat outDu
16、t control. The stove shall be equipped with a heat output control. The control shall vary the heat output linearly from minimum to maximum. The control shall have positive stops at the minimum and maximum settings. The relative heat output at different control settings shall be distinctly Provided b
17、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-44485 9999906 202b920 500 . MIL-PRF-44485 labeled and visually obvious. As a minimum, Low, Medium, and High settings shall be labeled. When the power control is moved to the position, the stove shall auto
18、matically ignite, warm up, and operate without the need for additional operator input. The stove shall meet the heat output requirements (see 3.2.1) within two minutes. When the power control is moved from the Ironv1 position to the lloff“ position, the stove shall automatically and immediately, (wi
19、thin 1 second), extinguish the flame and shut down all burner components. post-purge, the flame shall immediately extinguish, (within 1 second), and the post-purge must be complete within three minutes without damage to the stove or hazard to personnel. If the stove is equipped with a 3.2.15 Visual
20、indicators. The stove shall be equipped with visual indicators to provide information about the operational status. The visual indicators shall illuminate as necessary to provide all visual signals specified in 3.2.16 thru 3.2.18. All visual indicators shall be clearly labeled for signal identificat
21、ion. All visual signals shall be visible from the front of the stove and shall be visible in all operational and environmental conditions specified herein. A means shall be provided to check all visual indicators prior to operation of the stove for indicator malfunction. Fuses/bulbs shall be readily
22、 accessible for easy removal and replacement without the use of special tools. All visual signals shall be colored as follows: Green: Power on; Red: Automatic shutdown or fault condition, and Amber: All other conditions. 3.2.16 Fuel level indicator . The stove shall be equipped with a fuel level ind
23、icator located on the front of the stove. The indicator shall visually alert the operator when there is 1/8 and less of usable fuel remaining in the tank. As an alternate, the indicator shall visually alert the operator when there is 30 minutes of remaining operational time. 3.2.17 Refuel indicator.
24、 The control panel shall provide a visual signal to indicate the stove is refueling and when the automatic refueling procedure is complete (full fuel). 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-q4485 7777Ob 202b72L 447 MIL-PRF-44485 3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF444851996BURNERUNITFIELDFEEDING 野外 供给 放牧 PDF

链接地址:http://www.mydoc123.com/p-447253.html