ARMY MIL-PRF-44466 D-2006 HEATER WATER AND RATION (HWR)《水渗透加热器(HWR)》.pdf
《ARMY MIL-PRF-44466 D-2006 HEATER WATER AND RATION (HWR)《水渗透加热器(HWR)》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-44466 D-2006 HEATER WATER AND RATION (HWR)《水渗透加热器(HWR)》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND MIL-PRF-44466D 10 October 2006 SUPERSEDING MIL-PRF-44466C 6 September 2006 PERFORMANCE SPECIFICATION HEATER,WATER AND RATION (HWR) This specification is approved for use by all Departments and Agencies of the Department of Defense (DoD). 1. SCOPE 1.1 Scope. This specification covers one
2、type of heater for use by mounted troops that will heat rations, water for beverages and for limited personal hygiene (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents
3、cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this sp
4、ecification, whether or not they are listed. Comments, suggestions or questions on this document should be addressed to US Army Research, Development and Engineering Command, Natick Soldier Center, AMSRD-NSC-CF-S, 15 Kansas St., Natick, MA 01760-5018 or emailed to Robert.Bernazzaninatick.army.mil. S
5、ince contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil AMSC N/A FSC 7310 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-44466D 2.2 Go
6、vernment documents. 2.2.1 Standards. The following standards form part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement t
7、hereto, cited in the solicitation (see 6.2). STANDARDS MILITARY MIL-STD-461 - Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment MIL-STD-810 - Environmental Test Methods and Engineering Guidelines (Unless otherwise indicated, copies of the above
8、standards are available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094, or the ASSIST Online database at http:/assist.daps.dla.mil). 2.2.2. Government drawings. The following drawing forms part of this document to the extent specified herei
9、n: U. S. Army Soldier and Biological Chemical Command 5-13-6900 Heater, Water and Ration (HWR) 5-13-6901 Power Cord Assembly, Heater, Water, and Ration (HWR) (Copies of drawings are available from the U.S. Army Natick Research, Development and Engineering Center, Natick, MA 01760-5018 ) 2.3 Non-Gove
10、rnment publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of doc
11、uments not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-44466D THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) ASME/ANSI PTC 25.3 - Safety and
12、Relief Valves (Application for copies should be addressed to the American Society of Mechanical Engineers, United Engineering Center, 345 East 47th Street, New York, NY 10017, or Online at www.asme.org). NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) Standard No. 70 - National Electrical Code (Applicat
13、ion for copies should be addressed to the National Fire Protection Association, One Battery March Park, Quincy, MA 02269-9101, or Online at www.nfpa.org). NSF INTERNATIONAL Standard No. 2 - Food Service Equipment Standard No. 4 - Commercial Cooking, Rethermalization and Powered Hot Food Holding and
14、Transport Equipment (Application for copies should be addressed to NSF International, 3475 Plymouth Road, P. O. Box 1468, Ann Arbor, MI 48105, or Online at www.nsf.org). UNDERWRITERS LABORATORIES, INC. (UL) Standard 499 - Standard for Safety of Electric Heating Appliances (Application for copies sho
15、uld be addressed to the Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062-2096, or Online at ). 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this do
16、cument, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.1.1. 3 Provided by IHSNot for ResaleNo reproduction or
17、networking permitted without license from IHS-,-,-MIL-PRF-44466D 3.2 Operating requirements. The Heater, Water and Ration (HWR) shall satisfy the following operating requirements. 3.2.1 Temperature selection settings. The HWR shall have a low temperature setting of 1550F + 50F and a high temperature
18、 setting of 1850F + 50F. 3.2.2 Heating water. The HWR shall be capable of heating water. 3.2.3 Heating rations. The HWR shall be capable of heating 40 ounces of water in the main compartment and 5 Meal, Ready-to-Eat (MRE) entrees. 3.2.4 Capacity. The HWR shall have a minimum capacity of 1 gallon of
19、water in the main compartment. The removable inner container shall have a minimum capacity of 40 fluid ounces and 5 MRE entrees. 3.2.5 Control panel. The control panel shall consist of a low, off, high temperature selection switch, a power use indicator light (green), a heating element operation ind
20、icator light (white), an electric supply receptacle, and a water spigot. 3.2.6 Safety. The HWR shall be safe to operate in accordance with the standards specified herein. 3.2.6.1 Pressure relief. The HWR shall have the capability to relieve pressure buildup within the heating unit. 3.2.6.2 Automatic
21、 shutdown. The HWR shall automatically shut off power when the water level in the main compartment is empty or the internal temperature exceeds 2050F. Following cooldown, the HWR shall be capable of heating water. 3.2.6.3 Spillage. Closure and securing of the HWR lid shall form a watertight seal to
22、prevent spillage. 3.3 Interface and interoperability requirements. The HWR shall satisfy the following interface and interoperability requirements. 3.3.1 Operating current. The HWR shall operate on a 24/28 Volt DC system while drawing a current not less than 10 amps and not greater than 15 amps at 2
23、8 volts. 3.3.2 Low voltage detector. The HWR shall have a low voltage detector which activates the heater off latch if the voltage falls below 20 Volts DC. 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-44466D 3.3.3 Dimensions. The unit sh
24、all have overall dimensions no greater than those shown on Drawing No. 5-13-6900. The casing height shall vary in accordance with Type I or Type II vechicle mounting application as shown on Drawing No. 5-13-6900. 3.3.4 Power cord. The power cord as shown on Drawing No. 5-13-6901 shall be designed to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF44466D2006HEATERWATERANDRATIONHWR 渗透 加热器 HWRPDF

链接地址:http://www.mydoc123.com/p-447252.html