ARMY MIL-E-49383-1980 EYEPIECE BINOCULAR AN VSG-2《AN VSG-2双筒望远镜》.pdf
《ARMY MIL-E-49383-1980 EYEPIECE BINOCULAR AN VSG-2《AN VSG-2双筒望远镜》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-E-49383-1980 EYEPIECE BINOCULAR AN VSG-2《AN VSG-2双筒望远镜》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、-. .- I I 2 * NIL-E-LI7383 58 7799706 0363635 7 m r ,- MIL-E-49383(ER) 16 June 1980 MILITARY SPECIFICATION EYEPIECE, BIOCULAR, AN/VSG-2 This specification is approved for use by USAERADCOM, Department of the Army, and is available for use by all Departmentsand Agencies of the Department of Defense.
2、1. SCOPE 1.1 This specification covers the Eyepiece, Biocular, AN/VSG-2. 2. APPLICABLE DOCUMENTS 2.1 Issues of documents. The following documents of the issue in effect on date of invitation for bids or request for proposal, form a part of this specification to the extent specified herein. SPECIFICA
3、TIONS FEDERAL NN-P-7 1 QQ-S-78 1 NNN-P-40 PPP-B-5 6 6 PPP -B- 5 8 5 PPP-B-601 PPP-B-62 1 PPP-B-636 PPP-B-640 PPP-c-795 PPP -F- 3 20 PPP - S- 7 60 PPP-T-45 PPP-T-9 7 - Pallets, Material Handling, Wood, Stringer - Strapping, Steel, and Seals - Paper, Lens - Boxes, Folding, Paperboard - Boxes, Wood, Wi
4、rebound - Boxes, Wood, Cleated-Plywood - Boxes, Wood, Nailed and Lock-Corner - Boxes, Shipping, Fiberboard - Boxes, Fiberboard, Corrugated, Triple-Wall - Cushioning Material, Flexible, Cellular, Plastic Film for Packaging Applications - Fiberboard, Corrugated and Solid, Sheet Stock (Container Grade)
5、, and Cut Shapes - Strapping, Nonmetallic (and Connectors) - Tape, Gummed, Paper, Reinforced and Plain, for Sealing and Securing - Tape, Packaging/Industrial, Filament Reinforced Construction, 2-way and 4-way (Partial) Beneficial connnents (recommendations, additions, deletions) and any pertinent da
6、ta which may be of use in improving this document should be addressed to: Hq, USA Electronics Research and Development Command, ATTN: DRDEL-E, 2800 Powder Mill Road, Adelphi, MD 20783 by using the self-addressed Standard- ization Document Improvement Proposal (DD Form 1426) appearing at the end of t
7、his document or by letter. .A FSC 5855 THIS DOCUMENT 60MTABNS fi PAGES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-E-49383(ER) MILITARY MIL-P- 11 6 MIL-P-11268 STANDARDS MILITARY MIL-STD-105 MIL-STD-12 9 MIL-STD-147 MIL-STD-150 MIL-STD-252 M
8、IL-STD-454 MIL-STD-810 MIL-STD-1188 - Preservation-Packaging, Methods of - Parts, Materials, and Processes used in Electronic Equipment - Sampling Procedures and Tables for - Marking for Shipment and Storage - Palletized and Containerized Unit Loads, Inspection by Attributes 40 Inch x 48 Inch Pallet
9、s, Skids, Runners, or Pallet-Type Base - Photographic Lenses - Classification of Visual and Mechanical Defects for Equipment, Electronic, Wired, and Other Devices Electronic Equipment - Standard General Requirements for - Environmental Test Methods - Commercial Packaging-of Supplies and Equipment FE
10、DERAL FED-STD-595 - Colors DRAWINGS USA ELECTRONICS COMMAND DLSM-B-805103 - Eyepiece, Biocular, ANfVSG-2 (Copies of specifications, standards, drawings, and publications required by contractors in connection with specific procurement functions should be ob- tained from the procuring activity or as d
11、irected by the contracting officer.) 3. REQUIREMENTS 3.1 Item definition. The Eyepiece, Biocular, ANfVSG-2, herein known as the biocular eyepiece, magnifies the visual image at the output of the image inten- sifier and presents the scene to the eye of the viewer at the gunners or cormanders station.
12、 3.2 Construction. The biocular eyepiece shall be constructed in accordance with DLSM-B-805103 and as specified herein. 3.2.1 Weight. The total weight of the biocular eyepiece shall not exceed 10 pounds. I 2 . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
13、IHS-,-,-MIL-E-LI7383 58 7777706 0163637 O - - 1 I i . 3.3 First article. When specified in the contract (see 6.2), the contractor shall furnish first article units for inspection. 3.4 Materials, parts, and processes. Materials, parts, and processes shall be as specified herein and as shown on the ap
14、plicable drawings. parts, and pr.ocesces not specified shall be selected by the contractor in accordance with MIL-P-11268. Materials, 3.5 Components. The biocular eyepiece shall consist of optical elements and a housing . 3.6 Performance characteristics. 3.6.1 Field of view to the eye. The field of
15、view to the eye shall not be less than 39 degrees. 3.6.2 Magnification. The on-axis magnification shall not be less than 4.5 times . 3.6.3 Exit pupil, eye relief, and field overlap. The biocular eyepiece shall have a 60-mm exit pupil and a 60-mm eye relief for an on-axis image. Eye relief is measure
16、d from the vertex of the last glass surface to a plane per- pendicular to the optical axis in which the exit pupil is located. When two 5-mm exit pupils, decentered plus and minus 27.5 m from the optical axis (55-mm center-to-center separation) are located at the 601m eye relief dis- tance, the bioc
17、ular eyepiece shall provide at least 50-percent field overlap with field overlap calculated using the diameter and not the area of the over- lapping images. These conditions shall be satisfied at the fixed diopter set- t ing . 3.6.4 Biocular focus. The eyepiece shall be focussed at -2.5, - +0.3 diop
18、ters. 3.6.5 Field flatness. The biocular eyepiece shall have a flat tangential field within plus or minus 112 diopter across the outer 50 percent of the 40-mm format and within plus or minus 1/4 diopter across the central 50 per- cent of the 40-mm format at the fixed diopter setting. 3.6.6 Resolutio
19、n. The visual axial resolution (central 25 percent of the field of view) of the biocular eyepiece shall be not less than 35.9 line pairs per millimeter (Group 5, Element 2 of a 1951 Air Force Resolution Target). remaining field of view shall resolve 17.9 line pairs per millimeter (Group 4, Element 2
20、). The 3.6.7 Transmission. The transmission of the biocular eyepiece shall be at least 85 percent over the entire aperture for the region of spectral output of a P-20 phosphor. 3.6.8 Effective focal length (EFL). The effective focal length shall be 1.733, 20,017 inches. 3.6.9 Modulation transfer fun
21、ction (MTF). With a single 5-mm exit pupil decentered plus or minus 27.51mn from the optical axis and located at a 60-mm eye relief, the MTF of the biocular eyepiece shall be at least equal to the 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL
22、-E-Ll7383 58 777770b OLb3b38 2 W 1 MTF given below. an image placed at the center of the format. conditions shall be not less than the following: This MTF shall be measured at the fixed diopter setting for Axial MTF values under these MTF Frequency (lp/m) - 2 4 6 8 10 0.97 0.94 0.91 0.85 0.78 I 3.6.
23、10 Linear distortion. The linear distortion of the biocular eyepiece measured at the fixed diopter setting shall be 5.3, - +1.0 percent barrel distor- tion at the edge of the 40-mm format. 3.6.11 Back focal distance. The back focal distance shall not exceed 0.10 inch for an object projected 400 mm b
24、ehind (towards the biocular) for the nominal 60- exit pupil. 3.6.12 Sealing. The biocular eyepiece shall be assembled in a dry nitrogen atmosphere. of withstanding temperatures down to -57 C without producing condensation. eyepiece shall then be sealed. The eyepiece shall then be gurged with nitroge
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILE493831980EYEPIECEBINOCULARANVSG2ANVSG2 双筒望远镜 PDF

链接地址:http://www.mydoc123.com/p-444506.html