AIR FORCE MIL-I-27544C-1985 INDICATOR LIQUID OXYGEN QUANTITY《液氧量指示器》.pdf
《AIR FORCE MIL-I-27544C-1985 INDICATOR LIQUID OXYGEN QUANTITY《液氧量指示器》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE MIL-I-27544C-1985 INDICATOR LIQUID OXYGEN QUANTITY《液氧量指示器》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、c * e MIL-I-275q4C bb 9999906 0335240 9 = F- 58-a.3 MIL-I-27544C(USAF) SUPERSEDING MIL-I-27544B(USAF) 7 March 1966 5 APR 85 MILITARY SPECIFICATION INDICATOR, LIQUID OXYGEN QUANTITY This specification is approved for use by the Department of the :Air Force, and is available for use by all Departments
2、 and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the requirements for liquid oxygen quantity indicators. from O to 25 liters of liquid oxygen. The indicators are of th.e capacitance type and indicate 1.2 Classification. The indicators shall be of the followin
3、g types, as specified (see 6.2): GMU- 2 8 /A Cover glass coated with antireflection coating in GMU-2 8A/A Cover glass coated with high efficiency antireflection accordance with.MIL-C-675 coating as defined herein. 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications and standards.
4、Unless otherwise specified (see 6.2), the following specifications and standards of the issue listed in that issue of the Department of Defense Index of Specifications and Standards (DODISSI specified in the solicitation, form a part of this specification to the extent specified herein. SPECIFICATIO
5、NS FEDERAL PPP-B-601 Boxes, Wood Cleated-Plywood PPP-B-636 Boxes, Fiberboard MILITARY MIL-P-116 Preservation, Nethod of MIL-C- 6 7 5 Coating of Glass Optical Elements (Anti-Reflection) MIL-1-25645 Indicator, Liquid Oxygen Quantity, Capacitance Type, MIL-L-27160 Lighting, Instrument, Integral, White,
6、 General General Specification for Specification for _ _ - _.- - Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: the Engineering Division, San Antonio Air Logistics Center, Kelly AFB, Texas 7824
7、1 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. .- -. _-_ _. _- _-_ - - - - - -. . . - - T FSC 6680 THIS DOCUMENT CONTAINS -p- - PAGES Licensed by Information Handling Services_- -. MIL-I-27544C 66 777770b
8、 0335243 O NIL-1-27 544C( USAF) STANDARDS FEDERAL FED-STD-595 Colors MILITARY MIL-STD-129 MIL-STD-147 MIL-STD- 781 MIL-STD-794 MIL-STD-1186 BS 3 3 5 5 8 Marking for shipment and storage Palletized Unit Loads Reliability Tests, Exponential Distribution Part and Equipment Procedures for Packaging and
9、Packing of Cushioning, Anchoring, Bracing, Blocking and Waterproofing with Appropriate Test Methods Numeral and Letter , Aircraft Instrument Dial, Standard Form of (Copies of specifications and standards required by manufacturers in connection with specific acquisition functions should be obtained f
10、rom the contracting activity or as directed by the contracting officer), 2.1.2 Other publications. The following document(s) form a part of this specification to the extent specified herein. The issues of the documents which are indicated as DoD adopted shall be the issue listed in the current DoDIS
11、S and the supplement thereto, if applicable. * AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM D 3951 Standard Practice for Commercial Packaging (Application for copies of ASTM publications should be addressed to the American Society for Testing and Materials, 1916 Race Street, Philadelphia,
12、Pennsylvania 19103). JR 2.1.3 Order of precedence. In the event of a conflict between the text of this specification and the references cited herein, the text of this specification shall take precedence. 3. REQUIREMENTS 3.1 First Article. When specified, a sample shall be subjected to first article
13、inspection(see 4.3 and 6.3). 3.2 General specification. The requirements of MIL-1-25645 shall apply as requirements of this specification with the exceptions and additions called out herein. When the two specifications conflict, this specification shall govern. 3.3 Configuration. -The indicator shal
14、l consist of a single unit containing all the equipment necessary to meet the performance requirements specified herein and in MIL-1-25645. 2 %4 4% .4 Licensed by Information Handling ServicesMIL-I-275YYC bb W 7977906 0335242 2 WIDTH OF LINE OR +.O05 GRADUATION MIL-I-27544C (USAF) FINISH COLOR PER F
15、ED-STD-595 4- .O05 t- 2.000- - MARKING LIPUID OXYGEN HEIGHT OR LENGTH 5.010 FLAT SURFACE Numerals Liquid Oxygen Maior Grad Minor Grad NUMERALS h LETTERS SHALL COHFORH TO MS33558 .140 -140 .188 .125 Liters Background UNLESS OTHERWISE SPEC1 F I E D, DIMENSIONS ARE IN INCHES. 37875 4 37038 FIGURE 1. Di
16、al 3 Licensed by Information Handling ServicesAHPHENOL P/N 182-1-1000 OR EOUAL (INDICATOR CONNECTOR 1 SHIELDED LEAD TO INPUT CO- co- AX AX - 115 VOLT, 400 CYCLE -6 6 LOW LEVEL WARNING LICHT -c C 5 VOLT, 400 CYCLE E E - PRESS TO TEST F F - UNSHIELDED LEAD TO INPUT H H - - - - .I_ - - - GROUND J J - I
17、 (MAT IN G CONNECTOR) FIGURE 2. Connector Wiring 4 Licensed by Information Handling Services-_ MIL-I-27544C 66 777770b 0135244 b MIL-I-27544C (USAF) 3.4 Case. The length of the case shall not exceed 5.0 inches. 3.5 Dial. The dial for the indicator shall conform to figure 1. - 3.6 Cover glass coating
18、 (GMU-28A/A). The indicator cover glass for the GMU-28A/A indicator shall be provided with a reflection-reducing coating which meets the requirements of MIL-C-675 except that the following reflectance tolerances shall apply: Angle of Wavelength Percent Incidence (Millimicrons) Re lec t ance O“ 450 -
19、 675 0.6 maximum O“ 425 - 700 0.5 average 30 o 4.50 - 625 1.0 maximum 30“ 425 - 700 0.5 average 3.7 Electrical connector. The electrical connector shall be in accordance with figure 2. The indicator shall be designed internally so that it will function properly when the mating electrical connector i
20、s wired as shown on figure 2. The coaxial shield shall be grounded within the indicator. 3.8 Capacitance. For design purposes, the capacitance for zero reading shall be 303.5 micromicrof arad (uuf) . 3.9 Adjustments. The zero calibration adjustment for the indicator shall be capable of adjusting the
21、 pointer to zero indication over an input capaci- tance range of at least 295.0 uuf to 330.0 uuf. With the indicator adjusted to zero indication at 295.0 uuf input capacitance, the indicator shall be capable of calibration to full scale indication at 437.5 uuf input capacitance by means of the full
22、calibration adjustment. With the indicator adjusted to zero indication at 330.0 uuf input capacitance, the indicator shall be capable of calibration to full scale indication at 475.0 uuf input capacitance by means of the full calibration adjustment. 3.10 Weight. The indicator shall weigh not more th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILI27544C1985INDICATORLIQUIDOXYGENQUANTITY 液氧 指示器 PDF

链接地址:http://www.mydoc123.com/p-427948.html