AHRI 730 I-P-2013 Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers.pdf
《AHRI 730 I-P-2013 Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers.pdf》由会员分享,可在线阅读,更多相关《AHRI 730 I-P-2013 Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 2013 Standard for Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers AHRI Standard 730 (I-P) Price $15.00 (M) $30.00 (NM) Copyright 2013, by Air-Conditioning, Heating and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office IMPORTAN
2、T SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, ass
3、embled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does
4、 not certify or guarantee that any tests conducted under the standards/guidelines will not be non-hazardous or free from risk. Note: This standard supersedes AHRI Standard 730-2005. For SI ratings, see AHRI Standard 731 (SI)-2013. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose . 1 Section 2. Scop
5、e 1 Section 3. Definitions 1 Section 4. Test Requirements . 2 Section 5. Rating Requirements 2 Section 6. Minimum Data Requirements for Published Ratings 3 Section 7. Marking and Nameplate Data 3 Section 8. Conformance Conditions . 4 TABLES Table 1. Standard Rating Conditions for R-22, R-290, R-404A
6、, R-407C, R-410A, R-407A and R-507A 2 Table 2. Standard Rating Conditions for R-134a and R-600a . 2 Table 3. Standard Rating Conditions for R-744 3 Table 4. Recommended Pressure Drop Values for Rating and Selection of Suction Line Filters and Suction Line Filter Driers 3 APPENDICES Appendix A. Refer
7、ences - Normative . 5 Appendix B. References - Informative 5 AHRI STANDARD 730 (I-P)-2013 1 FLOW CAPACITY RATING OF SUCTION LINE FILTERS AND SUCTION LINE FILTER DRIERS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish, for refrigerant Suction Line Filters and Suction Line
8、Filter Driers (which may be referred to herein as “filters“): definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, includ
9、ing manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to Suction Line Filters and Suction Line Filter Driers, as defined in Section 3. 2.2
10、 Refrigerant. This standard applies to Suction Line Filters and Suction Line Filter Driers for use in systems employing refrigerants, R-22, R-134a, R-290, R-404A, R-407A, R-407C, R-410A, R-507A, R-600a, and R-744 as defined in ANSI/ASHRAE 34 with Addenda. Section 3. Definitions All terms in this doc
11、ument will follow the standard industry definitions in the ASHRAE Wikipedia website (http:/wiki.ashrae.org/index.php/ASHRAEwiki) unless otherwise defined in this section. 3.1 Permanent Installation. An installation intended to remain in the system for an indefinite period. 3.2 Published Rating. A st
12、atement of the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal size and type (identification) produced by the same manufacturer. The term Published Rating inclu
13、des the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated Rating Conditions. 3.2.1 Application Rating. A rating based on tests performed at application Rating Conditions (other than St
14、andard Rating Conditions). 3.2.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.3 Rating Conditions. Any set of operating conditions under which a single level of performance results and which causes only that level of performance to occur. 3.3.1 Standard Rating
15、Conditions. Rating conditions used as the basis of comparison for performance characteristics. 3.4 Refrigerant Flow Capacity. The maximum capacity of a filter drier attained at specified conditions as mentioned in ANSI/AHRI Standard 710, and 1 psi change in pressure, expressed in tons. 3.4.1 Pressur
16、e Drop. The pressure difference between the inlet and outlet of a filter, including its connections expressed in psi. 3.5 “Shall“ or “Should“. “Shall“ or “should“ shall be interpreted as follows: AHRI STANDARD 730 (I-P)-2013 2 3.5.1 Shall. Where “shall“ or “shall not“ is used for a provision specifi
17、ed, that provision is mandatory if compliance with the standard is claimed. 3.5.2 Should. “Should“ is used to indicate provisions which are not mandatory, but which are desirable as good practice. 3.6 Suction Line Filter. A manufactured device used in the suction line of a refrigeration system, for
18、the purpose of removing and retaining solid contaminants from the refrigerant. 3.7 Suction Line Filter Drier. A manufactured device used in the suction line of a refrigeration system, whose element is partly or wholly composed of a desiccant. It is intended to remove and retain moisture as well as s
19、olid contaminants from the refrigerant. 3.8 Temporary Installation. An installation intended to remain in the system for a short period of time with the purpose of cleaning a new or severely contaminated system. Section 4. Test Requirements 4.1 Test Requirements. All filter and filter-drier capacity
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI730IP2013FLOWCAPACITYRATINGOFSUCTIONLINEFILTERSANDSUCTIONLINEFILTERDRIERSPDF

链接地址:http://www.mydoc123.com/p-422571.html