AHRI 1160 I-P-2014 Performance Rating of Heat Pump Pool Heaters.pdf
《AHRI 1160 I-P-2014 Performance Rating of Heat Pump Pool Heaters.pdf》由会员分享,可在线阅读,更多相关《AHRI 1160 I-P-2014 Performance Rating of Heat Pump Pool Heaters.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 Price $15.00 (M) $30.00 (NM) 8Copyright 1994, by Air-Conditioning, Heating and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office 2014 Standard for Performance Rating of Heat Pump Pool Heaters AHRI Standard 1160 (I-P) Price $10.00 (M) $20.00 (NM) Copyrigh
2、t 2014, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office Note: This standard supersedes ANSI/AHRI Standard 1160-2009 (I-P). For SI ratings, see AHRI Standard 1161 (SI) 2014. AHRI CERTIFICATION PROGRAM PROVISIONS Scope of
3、 the Certification Program The certification program includes only Heat Pump Pool Heaters that are electrically driven, mechanical compression type systems as defined in the standard. Equipment covered: The program applies to Heat Pump Pool Heaters having 60 Hz single-phase or three-phase compressor
4、s. Certified Ratings The following ratings are verified by test: a. Standard Rating Heating Capacity - High Air Temperature - High Humidity, Btu/h b. Standard Rating COP - High Air Temperature - High Humidity, watts/watt c. Standard Rating Heating Capacity - High Air Temperature Mid-Humidity, Btu/h
5、d. Standard Rating COP - High Air Temperature Mid-Humidity, watts/watt e. Standard Rating Heating Capacity - Low Air Temperature Mid-Humidity, Btu/h f. Standard Rating COP - Low Air Temperature Mid-Humidity, watts/watt IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certi
6、fy or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized s
7、afety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or guarantee that any tests conducted under its standards/gu
8、idelines will be non-hazardous or free from risk. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope1 Section 3. Definitions1 Section 4. Classifications2 Section 5. Test Requirements.3 Section 6. Rating Requirements3 Section 7. Minimum Data Requirements for Published Ratings4 Secti
9、on 8. Operating Requirements4 Section 9. Marking and Nameplate Data5 Section 10. Conformance Conditions.5 TABLES Table 1. Classifications of Heat Pump Pool Heaters.2 Table 2. Standard Rating Conditions.3 APPENDICES Appendix A. References Normative.6 Appendix B. References Informative.6 AHRI STANDARD
10、 1160 (I-P)-2014 1 PERFORMANCE RATING OF HEAT PUMP POOL HEATERS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for Heat Pump Pool Heaters: definitions; classifications; test requirements; rating requirements; minimum data requirements for Published Ratings; operating re
11、quirements; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technol
12、ogy advances. Section 2. Scope 2.1 Scope. This standard applies to the rating and testing of complete factory-made Heat Pump Pool Heaters as defined in Section 3. 2.1.1 Energy Source. This standard applies only to air-source, electrically driven, mechanical compression type systems. 2.2 Exclusions.
13、This standard does not apply to the following: 2.2.1 Individual assemblies 2.2.2 Unitary Air-Conditioners as defined in ANSI/AHRI Standard 210/240 with capacities less than 65,000 Btu/h 2.2.3 Unitary heat operated air-conditioning equipment 2.2.4 Water-Source Heat Pumps as defined in ANSI/AHRI/ASHRA
14、E/ISO 13256-1 2.2.5 Commercial and Industrial Unitary Air Conditioning and Heat Pump Equipment with capacities of 65,000 Btu/h or greater as defined in ANSI/AHRI Standard 340/360 2.2.6 Single Package Vertical Air-Conditioners and Heat Pumps as defined in ANSI/AHRI Standard 390 2.2.7 Package Terminal
15、 Air-Conditioners and Heat Pumps as defined in AHRI Standard 310/380 (CSA-C744) Section 3. Definitions All terms in this document will follow the standard industry definitions in the ASHRAE Wikipedia website (http:/wiki.ashrae.org/index.php/ASHRAEwiki) unless otherwise defined in this section. 3.1 C
16、oefficient of Performance (COP). A ratio of the Heating Capacity in watts to the power input values in watts at any given set of Rating Conditions expressed in watts/watt. For heating COP, supplementary resistance heat shall be excluded. 3.1.1 Standard Coefficient of Performance. A ratio of the capa
17、city to power input value obtained at Standard Rating Conditions. AHRI STANDARD 1160 (I-P)-2014 2 3.2 Heat Pump Pool Heater. A factory-made assembly, which contains the air moving device, compressor, refrigerant-to-water heat exchanger and air-to-refrigerant heat exchanger using ambient air as the h
18、eat source. Models may consist of more than one assembly to be used together for the purpose of cooling and heating air. Models with separated assemblies shall be designed to be used together, and the requirements of rating outlined in this standard are based upon the use of matched assemblies. 3.2.
19、1 Heat Pump Pool Heaters shall provide the capability of heating pool water to achieve a controlled temperature, but may include the capabilities of pool water cooling, air-heating, air cooling, air-circulating, air-cleaning, or dehumidifying. 3.3 Heating Capacity. The capacity associated with the c
20、hange in water temperature, expressed in Btu/h. 3.4 Published Rating. A statement of the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal capacity and type (iden
21、tification) produced by the same manufacturer. As used herein, the term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated Rating Conditions. 3.4.1 Applica
22、tion Rating. A rating based on tests performed at application Rating Conditions (other than Standard Rating Conditions). 3.4.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.5 Rating Conditions. Any set of operating conditions under which a single level of perfor
23、mance results and which causes only that level of performance to occur. 3.5.1 Standard Rating Conditions. Rating Conditions used as the basis of comparison for performance characteristics. 3.6 “Shall“ or “Should“. “Shall“ or “should“ shall be interpreted as follows: 3.6.1 Shall. Where “shall“ or “sh
24、all not“ is used for a provision specified, that provision is mandatory if compliance with the standard is claimed. 3.6.2 Should. “Should“ is used to indicate provisions which are not mandatory but which are desirable as good practice. Section 4. Classifications 4.1 Classifications. A Heat Pump Pool
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI1160IP2014PERFORMANCERATINGOFHEATPUMPPOOLHEATERSPDF

链接地址:http://www.mydoc123.com/p-422479.html