1、 - STD-AGUA SbFTULi-ENGL 1996 m Ob87575 0004870 9Tb 9 . 96FTM4 Traceable Calibration of Master Gears at PTB by: Prof. Dr.-Ing Wolfgang Beyer TECHNICAL PAPER STD-ALMA SbFTMq-ENGL L99b Ob87575 0004873 832 E Paceable Calibration of Master Gears at PTB Prof. Dr.-Ing. Wolfgang Beyer The statements and op
2、inions contained herein are those of the author and should not be construed as an oficial action or opinion of the American Gear Manufacturers Association. Abstract The PTB (Physikalisch-Technische Bundesanstalt) is able to measure (calibrate) master gears for industry traceable to national gear sta
3、ndards and in compliance with the International System of Units (SI). For this purpose primary gear standards and standard measuring devices for the reference valuesFa, F, Fp (total profile deviation, total helix deviation, total cumulative pitch deviation) being available. To calibrate the master g
4、ears of industry, PTB mostly uses coordinate measuring machines (CMMs) which are traceable by instrument-specific calibration methods. In addition, with the aid of the PTBs primary standards, a task specific uncertainty of measurement is determined for all gearing calibrations carried out for indust
5、ry, which is taken into account as correction value when the transfer measurement uncertainty is stated. Copyright O 1996 American Gear Manufacturers Association 1500 King Street, Suite 201 Alexandria, Virginia, 22314 October, 1996 ISBN: 1-55589-671-5 1 - STDOAGMA SbFTM4-ENGL L97b = Ob87575 0004872
6、779 = Traceable Calibration of Master Gears at PTE Wolfgang Beyer, Director and Professor Physikalisch-Technische Bundesanstalt, Braunschweig/Germany 1 ntrochictioa The Physikalisch-Technische Bundesanstalt (PTB) is Germanys national metrology institute whose main task consists in ensuring, the real
7、ization gnd dissemination of the SI base units on a high technical level. Furthermore, when required, the physical quantities derived from the seven SI base units, such as the geometrical measurands derived from the base unit of metre - diameter, straight- ness, roundness, involute, pitch -, are als
8、o realized at the PTB through measurement standards or standard devices. The PTB standard devices mainly serve to calibrate the reference standards of the customers, thus proving traceability to national standards. This is in part made within the scope of an accreditation within the Deutscher Kalibr
9、ierdienst (DKD = German Calibration Service) in accordance with EN 45000 and ICO/IEC Guide 25. For about 25 years, the PTB has also created national measurement standards for gear quantities for cylindrical gears and set up the relevant traceability chains. Thus the requirements according to IS0 900
10、0 and following can be met, i.e. the link-up of simple measuring means to national measurement standards is possible via a traceability chain in accordance with the International System of Units (SI). In this contribution, the three highest steps of the traceability chains for F, Fg and Fp (Fig. 1)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AGMA96FTM41996TRACEABLECALIBRATIONOFMASTERGEARSATPTBPTB 追踪 校准 齿轮 PDF

链接地址:http://www.mydoc123.com/p-422407.html