AECMA PREN 3773-001-1994 Aerospace Series Circuit Breakers Single-Pole Temperature Compensated Rated Currents 1 A to 25 A Switching Capacity 65 IN 1 000 A Max Part 001 Technical S.pdf
《AECMA PREN 3773-001-1994 Aerospace Series Circuit Breakers Single-Pole Temperature Compensated Rated Currents 1 A to 25 A Switching Capacity 65 IN 1 000 A Max Part 001 Technical S.pdf》由会员分享,可在线阅读,更多相关《AECMA PREN 3773-001-1994 Aerospace Series Circuit Breakers Single-Pole Temperature Compensated Rated Currents 1 A to 25 A Switching Capacity 65 IN 1 000 A Max Part 001 Technical S.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、CEN PREN13773- 001 94 3404587 00b4452 169 AECMA STANDARD NORME AECMA AECMA NORM prEN 3773-00 1 Edition P 1 June 1994 DIT PAR LASSOCIATION EUROPEENNE DES CONSTRUCTEURS DE MATRIEL AROSPATIAL Technopolis - 175, rue Jean-Jacques Rousseau - F-92138 Issy-les-Moulineaux Cedex - Tl. (1) 47.36.98.76 UDC : 62
2、1.316.57:629.7 Descriptors : Aircraft industry, aircraft equipment, circuit breaker, manufacturing requirements, designation, marking ENGLISH VERSION Aerospace series Circuit breakers, single-pole, temperature compensated, rated currents 1 A to 25 A, switching capacity 65 Znll O00 A max. Part O01 :
3、Technical specification Srie arospatiale Disjoncteurs unipolaires compenss en temprature, intensits nominales 1 A 25 A, pouvoir de coupure 65 Inll O00 A max. Partie 001 : Spcification technique Luft- und Raumfahrt Temperaturkompensierte einpolige Schutzschalter, Nennstrme von 1 A bis 25 . Schaltverm
4、gen 65 In11 O00 A max. Teil 001 : Technische Lieferbedingungen This “Aerospace Series“ Prestandard has been drawn up under the responsibility of AECMA (Association Europenne des Constructeurs de Matriel Arospatial). It is published on green paper for the needs of AECMA-Members. It has been technical
5、ly approved by the experts of the concerned Technical Committee following comment by the Member countries. Subsequent to the publication of this prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identifica
6、tion of the standard. After examination and signature of the AECMA Standard Checking Centre (NPS) and formal agreement of the Official Services of the Member countries it will be submitted as a draft European Standard to CEN (European Committee for Standardization) for formal vote. Nota - Extra copi
7、es can be supplied by B.N.A.E. - Technopolis 54 - 199, rue Jean-Jacques Rousseau - 921 38 ISSY-LES-MOULINEAUX CEDEX Comments should be sent within six months after the date of publication to I Edition approved for publication AECMA 1994-06-30 I Technooolis - 175. rue Jean-Jacaues Rousseau I 921 38 I
8、ssy-les-Moulineaux Cedex - FRANCE C2 Chairman M. Le Cunff aecma 1994 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-CEN PREN*3773- 001 94 M 3404589 00
9、64453 OT5 Page 3 prEN 3773-001 : 1994 Rated currents (In) A 1 2 2,5 3 5 7,5 10 15 20 Code 01A 02A 2A5 03A 05A 7A5 10A 15A 20A 1 Scope 25 25A This standard specifies the required characteristics for single-pole temperature compensated circuit breakers with rated currents from 1 A to 25 A for use in a
10、ircraft electrical systems, at a temperature between - 55 OC and 125 OC and at a maximum altitude of 2 = 22 O00 rn. It shall be used together with EN 2350. These circuit breakers are for use in aircraft with power supplies in accordance with EN 2282. Range 1) Low Medium 2 Normative references High I
11、S0 71 37 : 1987 Aircraft - Environmental conditions and test procedures for airborne equipment (Endorsement of EUROCAE/EDI 4B and RTCA/DO-l60B) EN 2282 Aerospace series - Characteristics of aircraft electrical supplies EN 2350 Aerospace series - Circuit breakers - Technical specification EN 3042 Aer
12、ospace series - Quality assurance - EN aerospace products - Qualification procedure - Button marking 3 Definitions 1 2 2- 1 3 5 71 10 15 20 25 2 2 See EN 2350. 4 Description These circuit breakers are operated by a push-pull control button with trip free release, and delayed tripping ; they are expl
13、osion-proof. Their function is assured up to the short-circuit current. 5 Required characteristics 1) Range in accordance with 6.1 .I of EN 2350 Table 2 r- I 28 V d.c. 26 V a.c., frequency 400 Hz, single phase 115 V a.c., frequency 400 Hz, Voltage of aircraft electrical system single phase Previous
14、page is blank Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-CEN PRENs3773- O01 94 3404589 0064454 T3L Characteristics Closing force Opening force Ope
15、rating force Page 4 prEN 3773-001 : 1994 Requirements 3,5 N to 45 N 5 N to 30 N If an aircraft electrical power supply of variable frequency is used, the limit values (voltage and frequency) shall be specified, in accordance with EN 2282. Actuation component 6 Tests 6.1 Mechanical tests See table 3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AECMAPREN37730011994AEROSPACESERIESCIRCUITBREAKERSSINGLEPOLETEMPERATURECOMPENSATEDRATEDCURRENTS1ATO25ASWITCHINGCAPACITY65IN1000AMAXPART001TECHNICALSPDF

链接地址:http://www.mydoc123.com/p-420715.html