1、Standard Method of Test for Macrocell Slab Chloride Threshold AASHTO Designation: T 376M/T 376-171Technical Section: 4f, Metals Release: Group 2 (June 2017) American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001 TS-4f T 376M
2、/T 376-1 AASHTO Standard Specification for Macrocell Slab Chloride Threshold AASHTO Designation: T 376M/T 376-171Technical Section: 4f, Metals Release: Group 2 (June 2017) 1. SCOPE 1.1. This test method describes procedures to measure the chloride threshold concentration to initiate active corrosion
3、 of reinforcing bars in concrete using a macrocell slab type specimen. 1.2. Test measurement of chloride threshold concentration can be used to project service life of various reinforced concrete structural members when placed in corrosive environments. 2. REFERENCED STANDARDS 2.1. AASHTO Standards:
4、 M 31M/M 31, Deformed and Plain Carbon and Low-Alloy Steel Bars for Concrete Reinforcement M 43, Sizes of Aggregate for Road and Bridge Construction M 85, Portland Cement M 334M/M 334, Uncoated, Corrosion-Resistant, Deformed and Plain Chromium Alloyed, Billet-Steel Bars for Concrete Reinforcement an
5、d Dowels R 39, Making and Curing Concrete Test Specimens in the Laboratory T 22, Compressive Strength of Cylindrical Concrete Specimens T 119M/T 119, Slump of Hydraulic Cement Concrete T 121M/T 121, Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete T 152, Air Content of Freshly
6、 Mixed Concrete by the Pressure Method T 196M/T 196, Air Content of Freshly Mixed Concrete by the Volumetric Method T 277, Electrical Indication of Concretes Ability to Resist Chloride Ion Penetration 2.2. ASTM Standards: C33/C33M, Specification for Concrete Aggregates C1152/C1152M, Test Method for
7、Acid-Soluble Chloride in Mortar and Concrete G193, Standard Terminology and Acronyms Relating to Corrosion 3. TEST EQUIPMENT AND MATERIALS 3.1. VoltmeterHigh impedance voltmeter (at least one M) capable of measuring 0.001 mV. 3.2. Reference ElectrodeSaturated calomel electrode, as defined in ASTM G1
8、93. 2017 by the American Association of State Highway and Transportation Officials. All rights reserved. Duplication is a violation of applicable law.TS-4f T 376M/T 376-2 AASHTO 3.3. Resistor10-ohm ( 0.3 ) electrical resistor. Note 1Agency may also select a 100- resistor noting that a 100- resistor
9、will be more sensitive than a 10-, recognizing for a given current the measured voltage drop (the product of resistance and current) will be ten times higher. It should also be noted that a 100- resistor has a higher load on the circuit, so the current flows less easily. 3.4. Terminal BoxTerminal bo
10、xes house the electrical connection to the reinforcing bars. 3.5. Wire16-gauge 1.5-mm2 insulated copper wire is used to make the electrical connections to the bars. 3.6. Epoxy SealerA two part impermeable epoxy sealer shall be used to cover the sides of the specimens and the electrical connections.
11、It shall be applied in accordance with manufacturers recommendations. 3.7. Concrete MixCement shall be Type I or II per M 85. Coarse aggregate shall conform to ASTM C33 and M 43, with nominal maximum size between 9.5 and 12.5 mm 38and 1/2in. (See Section 4.9.) 3.8. Sodium Chloride Solution3.0 wt. pe
12、rcent sodium chloride solution is prepared by adding 30 g 1 oz. of NaCl to 970 g 34 oz. of distilled or deionized water. 3.9. Plastic Dams, 100-mm 4.0-in. wide and 150-mm 6.0-in. long with a minimum height of 75 mm 3.0 in. for placement on the test specimens. The wall thickness shall be 3 1 mm 18 1/
13、32in. 3.10. Marine (Medium- or High-Strength) Polyurethane Adhesivefor sealing the outside of the plastic dam to the top of the concrete specimen. Note 2The user shall determine an adhesive that is appropriate for a marine environment. 3.11. Rebar Test SpecimensThe tested rebars will include both th
14、e selected candidate test bar specimens conforming to M 334M/M 334, Table 1 and an uncoated comparator “black steel” M 31 bar. All rebar test specimens shall be No. 16 No. 5 steel bars as-received from the manufacturer under normal delivery conditions. Each bar shall be tapped to receive a 10-24 bol
15、t. Note 3All reinforcing bars shall be as sold and provided by the manufacturer, with or without mill scale. 4. TEST SPECIMEN PREPARATION 4.1. A minimum of three reinforced and three non-reinforced specimens shall be prepared. The two specimen types are identical except for reinforcement. 4.1.1. The
16、 test specimen shall be: 4.1.1.1. 114 mm 4.5 in. wide; 4.1.1.2. 152 mm 6.0 in. high; and 4.1.1.3. 280 mm 11.0 in. long 6 mm 0.25 in. for any dimension. 4.1.2. Reinforced test specimens shall contain one No. 16 No. 5 bar in the top mat electrically connected across a 10- ( 0.3 ) resistor to four No.
17、16 No. 5 bars in the bottom mat. The 2017 by the American Association of State Highway and Transportation Officials. All rights reserved. Duplication is a violation of applicable law.TS-4f T 376M/T 376-3 AASHTO concrete cover to the top and bottom steel shall be 25 1 mm 1 0.04 in. Figure 1 schematic
18、ally illustrates the geometry for reinforced specimens. 4.2. No. 16 No. 5 bars shall be cut to length of 381 mm 15.0 in. 4.3. Sharp edges on the ends of the bars shall be removed. 4.4. The ends of the bars shall be drilled and tapped to receive a 10-mm 38-in. long 10-24 threaded stainless steel bolt
19、. The bolt is used to make an electrical connection during the testing period. Figure 1Macroslab Reinforced Test Specimen (Source: MMFX Technologies Corp.) 4.5. The bars shall be cleaned with hexane to remove dust and oil. 4.6. If form release oil is to be used, it should be applied to the test spec
20、imen forms prior to the placement of the bars in the forms. 4.7. The bars shall be attached to the forms using marine adhesive per Section 3.10 with the specimens cast with concrete mix as indicated in Section 4.9. Place the bars in the molds so that approximately 40 mm 1.5 in. of the bars are prote
21、cted within each exit end from the concrete (minimizes edge effects). Both ends of each bar shall be coated with a two-part epoxy for a distance of 62 mm 2.5 in., except sufficient space shall be left uncoated at one end of each bar to attach the grounding clamps shown in Figure 1. This will expose
22、200 mm 8.0 in. of steel. Place the bars in the specimen formwork with the longitudinal ribs so that they are nearer the side of the beam, with both ridges equidistant from the top or bottom of the specimen. Note 4Caution should be taken not to introduce other metals that may stay in the concrete. 4.
23、8. Make the concrete specimens in accordance with R 39, using the same source of materials. Determine the air content, using either T 152 or T 196M/T 196. The watercement ratio (w/c) shall not exceed 0.5. The minimum slump is 50 mm 2.0 in. (See T 119M/T 119.) Place and consolidate the concrete in th
24、e molds in accordance with R 39. 4.9. Macrocell Slab Concrete Mix Design and CastingThe concrete used for the macrocell slab specimens will meet the requirements of the reference mix design below or a mix design set by the specifying agency. Macrocell slab casting and curing shall be in accordance w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOT376MT3762017STANDARDMETHODOFTESTFORMACROCELLSLABCHLORIDETHRESHOLDPDF

链接地址:http://www.mydoc123.com/p-418326.html