1、Standard Method of Test for Viscosity of Asphalts by Vacuum Capillary Viscometer AASHTO Designation: T 202-15 ASTM Designation: D2171/D2171M-10 American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001 TS-2b T 202-1 AASHTO Stan
2、dard Method of Test for Viscosity of Asphalts by Vacuum Capillary Viscometer AASHTO Designation: T 202-15 ASTM Designation: D2171/D2171M-10 AASHTO T 202-15 is identical to ASTM D2171/D2171M-10 except for the following provisions: 1. The following reference is added: R 16, Regulatory Information for
3、Chemicals Used in AASHTO Tests. 2. Replace the last sentence in Section 6.3 with the following: The efficiency of the stirring and the balance between heat loss and heat input must be such that the temperature of the bath medium does not vary by more than 0.1C (0.2F) over the length of the viscomete
4、r, or from viscometer to viscometer in the various bath positions. 3. Replace Section 8.1.1 with the following: 8.1.1 Maintain the bath at the test temperature within 0.1C (0.2F). Apply the necessary corrections, if any, to all thermometer readings. 4. Replace Section 11 with the following: 11. Prec
5、ision and Bias 11.1 PrecisionCriteria for judging the acceptability of viscosity results obtained by this method are given in Table 1. 11.1.1 Single-Operator Precision (Repeatability)The figures in Column 2 of Table 1 are the coefficients of variation that have been found to be appropriate for the c
6、onditions of test described in Column 1. Two results obtained in the same laboratory, by the same operator using the same equipment, in the shortest practical period of time, should not be considered suspect unless the difference in the two results, expressed as a percent of their mean, exceeds the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOT2022015STANDARDMETHODOFTESTFORVISCOSITYOFASPHALTSBYVACUUMCAPILLARYVISCOMETERPDF

链接地址:http://www.mydoc123.com/p-418148.html