《AASHTO R 64-2015 Standard Practice for Sampling and Fabrication of 50-mm (2-in.) Cube Specimens Using Grout (Non-Shrink) or Mortar.pdf》由会员分享,可在线阅读,更多相关《AASHTO R 64-2015 Standard Practice for Sampling and Fabrication of 50-mm (2-in.) Cube Specimens Using Grout (Non-Shrink) or Mortar.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Standard Practice for Sampling and Fabrication of 50-mm (2-in.) Cube Specimens Using Grout (Non-Shrink) or Mortar AASHTO Designation: R 64-151American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001 TS-3b R 64-1 AASHTO Standar
2、d Practice for Sampling and Fabrication of 50-mm (2-in.) Cube Specimens Using Grout (Non-Shrink) or Mortar AASHTO Designation: R 64-1511. SCOPE 1.1. This practice covers field sampling and fabrication and initial curing of 50-mm (2-in.) cube specimens of nonshrink grout or mortar materials, or both.
3、 1.2. The values stated in either inch-pound or SI units shall be regarded separately as standard. The inch-pound units are shown in parentheses. The values stated might not be exact equivalents; therefore, each system must be used independently of the other. Note 1“Unit weight” was the previous ter
4、minology used to describe the property determined by this practice, which is mass per unit volume. 1.3. The text of this practice references notes and footnotes that provide explanatory information. These notes and footnotes (excluding those in tables) shall not be considered as requirements of this
5、 practice. 1.4. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Wa
6、rningFresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standard: R 60, Sampling Freshly Mixed Concrete 3. TERMINOLOGY 3.1. Definitions of Terms Specific to This Standard: 3.1.1. plastic mixma
7、terial viscous enough that an indentation will be left in the surface of the grout after tamping. 3.1.2. fluid mixmaterial fluid enough that little or no indentation will be left in the surface after puddling. 4. SIGNIFICANCE AND USE This practice provides standardized requirements for sampling, fab
8、rication, and curing of 50-mm (2-in.) cube specimens of nonshrink grout and mortar materials. 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-3b R 64-2 AASHTO 5. APPARATUS 5.1. Specimen Molds Includin
9、g Cover Plate(s)The 50-mm (2 in.) cube specimen molds shall be tight-fitting and made of brass or other suitable material. This material shall not be susceptible to attack by the cement mortar. The mold portion shall have not more than three cube compartments and shall be separable into not more tha
10、n two parts. The mold halves, when assembled, shall be positively held together. The working surface of the cover plate(s) shall be plane. The interior faces of the molds shall conform to the tolerances of Table 1. Table 1Permissible Variations of Specimen Molds Parameter 50-mm Cube Molds 2-in. Cube
11、 Molds New In Use New In Use Planeness of sides 0.025 mm 0.05 mm 0.001 in. 0.002 in. Distance between opposite sides 50 mm 0.13 mm 50 mm 0.50 mm 2 in. 0.005 in. 2 in. 0.02 in. Height of each compartment 50 mm + 0.25 mm to 0.13 mm 50 mm + 0.25 mm to 0.38 mm 2 in. + 0.01 in. to 0.005 in. 2 in. + 0.01
12、in. to 0.015 in. Angle between adjacent facesa90 0.5 90 0.5 90 0.5 90 0.5 aMeasured at points slightly removed from the intersection. Measured separately for each compartment between all the interior faces and the adjacent face and between interior faces and top and bottom planes of the mold. 5.2. T
13、amperA nonabsorptive, nonabrasive, nonbrittle material such as a hard rubber compound having a Shore A durometer hardness of 80 10. The tamper shall have a cross section of about 13 mm by 25 mm (1/2in. by 1 in.) and a length of 125 to 150 mm (5 to 6 in.). The tamping face shall be flat and at right
14、angles to the length of the tamper. 5.3. TrowelSteel bladed, 100 to 150 mm (4 to 6 in.) in length, with straightedges. 5.4. Other EquipmentRubber gloves, scoop, clamps to secure the cover plate, light release oil for oiling the molds, small brush or lint-free cloth for applying and removing excess r
15、elease oil, and burlap or wrapping cloth capable of retaining moisture. 6. SAMPLING 6.1. Samples shall be obtained in accordance with R 60 when the batch equals or exceeds 1 m3(1 yd3). When the batch is less than 1 m3(1 yd3), sample from the batch after discharge. If remixing is required, sample aft
16、er remixing. Begin molding the specimens within an elapsed time of not more than 21/2min from completion of the mixing. Note 2This practice is to be used only for grouts with 100 percent passing the 9.5-mm (3/8-in.) sieve. 6.2. Obtain a representative sample of the mix. Samples shall be a minimum si
17、ze of 2000 g (4 lb) for each set of three cubes to be fabricated. 7. PROCEDURE 7.1. Assemble both portions of the mold and the bottom cover plate. All joints shall be watertight. If not watertight, seal the surfaces where the halves of the mold join by applying a coating of light cup grease (nonwate
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOR642015STANDARDPRACTICEFORSAMPLINGANDFABRICATIONOF50MM2INCUBESPECIMENSUSINGGROUTNONSHRINKORMORTARPDF

链接地址:http://www.mydoc123.com/p-418015.html