《AASHTO R 63-2013 Standard Practice for Solid Wall High-Density Polyethylene (HDPE) Conduit for Non-Pressure Applications Used for the Protection of Power and Telecommunications Cab.pdf》由会员分享,可在线阅读,更多相关《AASHTO R 63-2013 Standard Practice for Solid Wall High-Density Polyethylene (HDPE) Conduit for Non-Pressure Applications Used for the Protection of Power and Telecommunications Cab.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Standard Practice for Solid Wall High-Density Polyethylene (HDPE) Conduit for Non-Pressure Applications Used for the Protection of Power and Telecommunications Cables AASHTO Designation: R 63-13 American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 2
2、49 Washington, D.C. 20001 TS-4b R 63-1 AASHTO Standard Practice for Solid Wall High-Density Polyethylene (HDPE) Conduit for Non-Pressure Applications Used for the Protection of Power and Telecommunications Cables AASHTO Designation: R 63-13 1. SCOPE 1.1. This standard practice provides guidance to e
3、ngineers in the specification of HDPE conduit used in buried applications for the protection of power cables for use in highways, airport lighting, traffic control, and fiber optic data and command and control applications in State Transportation Projects. This standard practice covers conduit used
4、in the following manner: HDPE pipe used as a casing for the protection of smaller individual conduits, innerducts, in road crossings; HDPE conduit in coils, on steel reels, or in straight sticks; and CIC (cable in conduit), when power cable (conductors), CATV (coaxial), or fiber optic cable is insta
5、lled in the conduit at the conduit manufacturing facility. HDPE pipe is commonly installed in standalone duct installations for the protection of power cable (conductors), CATV (coaxial cable), or fiber optic cable. HDPE pipe is commonly installed in standalone duct applications for road crossings w
6、hen the bury depth is sufficient to avoid degradation effects to the road. HDPE pipe is commonly installed in standalone duct applications parallel to the roadway. 1.2. This standard practice covers material, dimensional, workmanship, and performance requirements for use of conduit in non-pressure a
7、pplications. 1.3. HDPE conduit meeting the guidelines of this standard practice shall be outside diameter (OD)-controlled solid wall, with or without external or internal ribs. The sizing shall be Iron Pipe Size or Schedule as noted in Tables 6 and 7. The internal or external surface may contain a c
8、oextruded layer provided the finished conduit meets the product requirement in this standard. 1.4. This standard practice does not include guidelines for installation of HDPE conduit. Typical installation methods include trenching, plowing, and Horizontal Directional Drilling (HDD). Consult the PPI
9、(Plastic Pipe Institute) Handbook of Polyethylene Pipe and TN (Technical Notes) on the PPI website, http:/plasticpipe.org, for further information and guidance on installation methods. 2. REFERENCED DOCUMENTS 2.1. ASTM Standards: D570, Standard Test Method for Water Absorption of Plastics 2015 by th
10、e American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4b R 63-2 AASHTO D618, Standard Practice for Conditioning Plastics for Testing D638, Standard Test Method for Tensile Properties of Plastics D790, Standard Test M
11、ethods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials D792, Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement D1238, Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plasto
12、meter D1505, Standard Test Method for Density of Plastics by the Density-Gradient Technique D1600, Standard Terminology for Abbreviated Terms Relating to Plastics D1603, Standard Test Method for Carbon Black Content in Olefin Plastics D1693, Standard Test Method for Environmental Stress-Cracking of
13、Ethylene Plastics D2122, Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings D2239, Standard Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on Controlled Inside Diameter D2412, Standard Test Method for Determination of External Loading Characteristics
14、 of Plastic Pipe by Parallel-Plate Loading D2444, Standard Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling Weight) D2839, Standard Practice for Use of a Melt Index Strand for Determining Density of Polyethylene D3350, Standard Spec
15、ification for Polyethylene Plastics Pipe and Fittings Materials D3485-02, Standard Specification for Smooth-Wall Coilable Polyethylene (PE) Conduit (Duct) for Preassembled Wire and Cable (Withdrawn 2011) D4703, Standard Practice for Compression Molding Thermoplastic Materials into Test Specimens, Pl
16、aques, or Sheets D4883, Standard Test Method for Density of Polyethylene by the Ultrasound Technique D6070, Standard Test Methods for Physical Properties of Smooth-Wall, Coilable, Polyethylene (PE) Conduit (Duct) for Preassembled Wire and Cable F412, Standard Terminology Relating to Plastic Piping S
17、ystems F1804, Standard Practice for Determining Allowable Tensile Load for Polyethylene (PE) Gas Pipe During Pull-In Installation F1962, Standard Guide for Use of Maxi-Horizontal Directional Drilling for Placement of Polyethylene Pipe or Conduit Under Obstacles, Including River Crossings F2160, Stan
18、dard Specification for Solid Wall High Density Polyethylene (HDPE) Conduit Based on Controlled Outside Diameter (OD) 2.2. National Electrical Manufacturers Association (NEMA) Standard: NEMA TC 7, Smooth-Wall Coilable Electrical Polyethylene Conduit 2.3. Underwriters Laboratories (UL) Standards: UL 6
19、51A, High Density Polyethylene HDPE Conduit Note 1In November of 2011, UL changed the specification numbers (no changes in the body of the specifications). Prior to November 2011, UL 651A was PVC and HDPE in stick form and UL 651B was HDPE in coiled form. As of November 2011, UL 651 now addresses PV
20、C in stick-form conduit and UL 651A addresses HDPE in stick-form and coiled-form conduit. UL 1990, Nonmetallic Underground Conduit with Conductors 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4b R
21、63-3 AASHTO 2.4. National Fire Protection Association (NFPA 70); National Electric Code: NFPA 70; National Electric Code (NEC), 2011: i. Article 353: High Density Polyethylene Conduit; Type HDPE Conduit ii. Article 354: Nonmetallic Underground Conduit with Conductors: Type NUCC 3. TERMINOLOGY 3.1. D
22、efinitionsGeneral terms used in this standard are as defined in ASTM F412, ASTM F2160, UL 651A, and NEMA TC 7. Abbreviations are in accordance with ASTM D1600, unless otherwise specified. 3.2. Definitions of Terms Specific to This Standard: 3.2.1. CATV and CCTV, ncable television and closed circuit
23、television 3.2.2. cell classification (cell class), nmethod of identifying thermoplastic materials such as HDPE, as specified in ASTM D3350, where the cell classification is based on six properties for PE. 3.2.3. CIC (cable in conduit), nwhen the power or fiber cable is installed during the extrusio
24、n process of the HDPE conduit. 3.2.4. conduit (duct), na tubular raceway for carrying power, communications, or other wires and cable. 3.2.5. EPEC A, nElectrical Polyethylene Conduit A. This type represents the nominal dimensions as specified in standard dimension ratio (SDR) 17. 3.2.6. EPEC B, nEle
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOR632013STANDARDPRACTICEFORSOLIDWALLHIGHDENSITYPOLYETHYLENEHDPECONDUITFORNONPRESSUREAPPLICATIONSUSEDFORTHEPROTECTIONOFPOWERANDTELECOMMUNICATIONSCABPDF

链接地址:http://www.mydoc123.com/p-418014.html