AASHTO M 273-2011 Standard Specification for Precast Reinforced Concrete Box Sections for Culverts Storm Drains and Sewers with Less Than 2 ft of Cover Subjected to Highway Loading.pdf
《AASHTO M 273-2011 Standard Specification for Precast Reinforced Concrete Box Sections for Culverts Storm Drains and Sewers with Less Than 2 ft of Cover Subjected to Highway Loading.pdf》由会员分享,可在线阅读,更多相关《AASHTO M 273-2011 Standard Specification for Precast Reinforced Concrete Box Sections for Culverts Storm Drains and Sewers with Less Than 2 ft of Cover Subjected to Highway Loading.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、TS-4a M 273-1 AASHTO Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers with Less Than 2 ft of Cover Subjected to Highway Loadings AASHTO Designation: M 273-111ASTM Designation: C 850-95a 1. SCOPE 1.1. This specification covers single-cell, pre
2、cast reinforced concrete box sections with less than 2 ft of cover subjected to highway loadings and intended to be used for the construction of culverts and for the conveyance of storm water, industrial wastes, and sewage. 1.2. A complete metric companion to M 273 has been developedM 273M; therefor
3、e, no metric equivalents are presented in this specification. Note 1This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product
4、 depends upon the proper selection of the box section, bedding, backfill, controlled manufacture in the plant, and care that the installation conforms to the construction specifications. The owner of the precast reinforced concrete box sections specified herein is cautioned that the loading conditio
5、ns and the field requirements must be correlated with the box sections specified and that inspection at the construction site must be provided. Note 2AASHTO M 259 is to be used for box sections subjected to highway loading with 2 ft or more earth cover, or subjected to dead load only. Note 3If load-
6、and-resistance factor design (LRFD) is required, then use ASTM C 1577. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standards: M 6, Fine Aggregate for Hydraulic Cement Concrete M 31M/M 31, Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement M 32M/M 32, Steel Wire, Plain, for Concrete Reinforcemen
7、t M 55M/M 55, Steel Welded Wire Reinforcement, Plain, for Concrete M 80, Coarse Aggregate for Hydraulic Cement Concrete M 85, Portland Cement M 221M/M 221, Steel Welded Wire Reinforcement, Deformed, for Concrete M 225M/M 225, Steel Wire, Deformed, for Concrete Reinforcement M 240M/M 240, Blended Hyd
8、raulic Cement M 259, Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers 2013 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 273-2 AASHTO M 262, Concrete Pipe and Related
9、Products M 295, Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete T 22, Compressive Strength of Cylindrical Concrete Specimens T 23, Making and Curing Concrete Test Specimens in the Field T 280, Concrete Pipe, Manhole Sections, or Tile Standard Specifications for Highway Bridges
10、2.2. ASTM Standards: C 1116/C 1116M, Standard Specification for Fiber-Reinforced Concrete C 1577, Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers Designed According to AASHTO LRFD 3. TERMINOLOGY 3.1. DefinitionsFor definitions of
11、terms relating to concrete pipe, see M 262. 4. TYPES 4.1. Precast reinforced concrete box sections manufactured in accordance with this specification shall be of the types identified in Tables 1 and 2, and shall be designated by type, span, and rise. 5. BASIS OF ACCEPTANCE 5.1. Acceptability of the
12、box sections produced in accordance with Section 7 shall be determined by the results of the concrete compressive strength tests described in Section 10, by the material requirements described in Section 6, and by inspection of the finished box sections. 5.2. Box sections shall be considered ready f
13、or acceptance when they conform to the requirements of this specification. 6. MATERIALS 6.1. Reinforced ConcreteThe reinforced concrete shall consist of cementitious materials, mineral aggregates, and water, in which steel has been embedded in such a manner that the steel and concrete act together.
14、6.2. Cementitious Materials: 6.2.1. CementCement shall conform to the requirements for portland cement of M 85 or shall be portland blast-furnace slag cement or portland-pozzolan cement conforming to the requirements of M 240M/M 240, except that the pozzolan constituent in the Type IP portland-pozzo
15、lan cement shall be fly ash and shall not exceed 25 percent by weight. 2013 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 273-3 AASHTO Table 1Design Requirements for Precast Reinforced Concrete Box
16、Sections with Less Than 2 ft of Cover Subjected to HS20 Loadinga Box Section S R, ftbThickness, in. Circumferential Reinforcement AreascDistribution Reinforcement AreasdTop Slab Bottom Slab Wall As1As2As3As4As7As8As5As63 2 7 6 4 0.17 0.34 0.20 0.13e0.17e0.14e0.17e0.17e3 3 7 6 4 0.13e0.36 0.22 0.13e0
17、.17e0.14e0.18 0.17e4 2 71/26 5 0.21 0.37 0.20 0.13e0.18e0.14e0.18e0.18e4 3 71/26 5 0.18 0.41 0.23 0.13e0.18e0.14e0.20 0.18e4 4 71/26 5 0.16 0.43 0.24 0.13e0.18e0.14e0.21 0.18e5 3 8 7 6 0.22 0.41 0.22 0.14e0.19e0.17e0.19e0.19e5 4 8 7 6 0.19 0.44 0.24 0.14e0.19e0.17e0.21 0.19e5 5 8 7 6 0.16 0.46 0.26
18、0.14e0.19e0.17e0.22 0.19e6 3 8 7 7 0.30 0.42 0.21 0.17e0.19e0.17e0.19e0.19e6 4 8 7 7 0.59 0.46 0.24 0.17e0.19e0.17e0.20 0.19e6 5 8 7 7 0.23 0.48 0.26 0.17e0.19e0.17e0.21 0.19e6 6 8 7 7 0.20 0.51 0.29 0.17e0.19e0.17e0.22 0.19e7 4 8 8 8 0.32 0.45 0.24 0.19e0.19e0.19e0.19e0.19e7 5 8 8 8 0.29 0.48 0.27
19、0.19e0.20 0.19e0.19e0.19e7 6 8 8 8 0.27 0.51 0.29 0.19e0.20 0.19e0.20 0.19e7 7 8 8 8 0.25 0.53 0.32 0.19e0.23 0.19e0.21 0.19e8 4 8 8 8 0.37 0.51 0.27 0.19e0.19e0.19e0.19e0.19e8 5 8 8 8 0.34 0.53 0.30 0.19e0.19e0.19e0.20 0.19e8 6 8 8 8 0.32 0.56 0.33 0.19e0.25 0.19e0.21 0.19e8 7 8 8 8 0.30 0.58 0.35
20、0.19e0.27 0.22 0.22 0.19e8 8 8 8 8 0.28 0.60 0.38 0.23 0.29 0.26 0.22 0.19e9 5 9 9 9 0.34 0.50 0.29 0.22e0.22e0.22e0.22e0.22e9 6 9 9 9 0.32 0.53 0.32 0.22e0.22e0.22e0.22e0.22e9 7 9 9 9 0.30 0.55 0.35 0.22e0.25 0.22e0.22e0.22e9 8 9 9 9 0.28 0.57 0.38 0.22e0.27 0.24 0.22e0.22e9 9 9 9 9 0.27 0.58 0.41
21、0.25 0.30 0.28 0.22e0.22e10 5 10 10 10 0.34 0.48 0.29 0.24e0.24e0.24e0.24e0.24e10 6 10 10 10 0.32 0.50 0.32 0.24e0.24e0.24e0.24e0.24e10 7 10 10 10 0.31 0.52 0.35 0.24e0.24e0.24e0.24e0.24e10 8 10 10 10 0.29 0.54 0.38 0.24e0.26 0.24e0.24e0.24e10 9 10 10 10 0.27 0.55 0.40 0.24e0.28 0.26 0.24e0.24e10 10
22、 10 10 10 0.27 0.57 0.43 0.27 0.32 0.31 0.24e0.24e11 4 11 11 11 0.38 0.44 0.26e0.26e0.26e0.26e0.26e0.26e11 6 11 11 11 0.33 0.48 0.32 0.26e0.26e0.26e0.26e0.26e11 8 11 11 11 0.29 0.51 0.38 0.26e0.26e0.26e0.26e0.26e11 10 11 11 11 0.28 0.54 0.43 0.26e0.29 0.29 0.26e0.26e11 11 11 11 11 0.28 0.56 0.46 0.3
23、0 0.34 0.34 0.26e0.26e12 4 12 12 12 0.40 0.42 0.29e0.29e0.29e0.29e0.29e0.29e12 6 12 12 12 0.35 0.46 0.32 0.29e0.29e0.29e0.29e0.29e12 8 12 12 12 0.31 0.49 0.38 0.29e0.29e0.29e0.29e0.29e12 10 12 12 12 0.29e0.53 0.43 0.29e0.29e0.29e0.29e0.29e12 12 12 12 12 0.29e0.57 0.50 0.33 0.36 0.37 0.29e0.29ea Desi
24、gn requirements are based on maximum effects resulting from cover conditions ranging from 0 to 2 ft and the material and soil properties and loading data shown in Appendix X1. For modified or special designs, see Section 7.2. bThe box section designation, for example 3 by 2, indicates interior horiz
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOM2732011STANDARDSPECIFICATIONFORPRECASTREINFORCEDCONCRETEBOXSECTIONSFORCULVERTSSTORMDRAINSANDSEWERSWITHLESSTHAN2FTOFCOVERSUBJECTEDTOHIGHWAYLOADINGPDF

链接地址:http://www.mydoc123.com/p-417756.html