ABS 204 NOTICE 1-2017 GUIDE FOR EXHAUST EMISSION ABATEMENT.pdf
《ABS 204 NOTICE 1-2017 GUIDE FOR EXHAUST EMISSION ABATEMENT.pdf》由会员分享,可在线阅读,更多相关《ABS 204 NOTICE 1-2017 GUIDE FOR EXHAUST EMISSION ABATEMENT.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 GUIDE FOR EXHAUST EMISSION ABATEMENT OCTOBER 2013 NOTICE NO. 1 July 2017 The following Rule Changes were approved by the ABS Rules Committee on 7 June 2017 and become EFFECTIVE AS OF 1 JULY 2017. (See http:/www.eagle.org for the consolidated version of the Guide for Exhaust Emission Abatement 2013,
2、 with all Notices and Corrigenda incorporated.) Notes - The date in the parentheses means the date that the Rule becomes effective for new construction based on the contract date for construction. (See 1-1-4/3.3 of the ABS Rules for Conditions of Classification Offshore Units and Structures (Part 1)
3、.) SECTION 3 EGC SELECTIVE CATALYTIC REDUCTION SYSTEMS 9 SCR System Equipment (Revise Paragraph 3/9.5, as follows:) 9.5 SCR Reductant System (1 July 2017) Exhaust emission abatement systems using SCR technologies usually use an ammonia reductant introduced as a urea/water solution into the exhaust s
4、tream, prior to the catalyst blocks. For automotive and land-based engine applications, this reductant solution is typically a 32% urea solution meeting the ISO 22241 standard (AUS 32). A specific marine engine urea standard utilizing a 40% (AUS 40) urea solution has been developed by ISO (18611 ser
5、ies). The SCR manufacturer is to detail the specification of the reductant solution(s) appropriate for use with the SCR system and any specific installation considerations that may be applicable for storage, handling, and use of the reductant. Urea is typically not classified as dangerous according
6、to MSDS but can be an eye, skin, and respiratory irritant, and hence there is a need for the provision of appropriate safety features and personnel protective equipment. The key fluid media components of the SCR reductant system typically comprise reductant storage tank, pumps, filters, dosing units
7、, and injectors with associated control system. The specific requirements for SCR reductant system components using urea as a reductant are given under 3/11.3 of this Guide. Arrangements using alternative reductant solutions, such as aqueous ammonia or anhydrous ammonia, will be considered on a case
8、-by-case basis. ABSGUIDE FOR EXHAUST EMISSION ABATEMENT .2013 1 Notice No. 1 July 2017 11 SCR System Piping 11.3 Reductant Piping Systems Urea Solution (Revise Subparagraph 3/11.3.3, as follows:) 11.3.3 Arrangement of the Urea Storage Tank (1 July 2017) i) The urea storage tank is not to be situated
9、 where spillage or leakage therefrom can constitute a hazard by falling onto combustibles or heated surfaces and is to be located in a well-ventilated area away from heat sources. The urea storage tank may be located within the engine room. If installed in a separate compartment, the area is to be s
10、erved by an effective mechanical supply and exhaust ventilation system providing not less than 6 air changes per hour which is independent from the ventilation system of accommodation, service spaces, or control stations. In addition, if located in a separate compartment, the ventilation system is t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ABS204NOTICE12017GUIDEFOREXHAUSTEMISSIONABATEMENTPDF

链接地址:http://www.mydoc123.com/p-400779.html