ASTM D7648 D7648M-2018 Standard Practice for Active Soil Gas Sampling for Direct Push or Manual-Driven Hand-Sampling Equipment.pdf
《ASTM D7648 D7648M-2018 Standard Practice for Active Soil Gas Sampling for Direct Push or Manual-Driven Hand-Sampling Equipment.pdf》由会员分享,可在线阅读,更多相关《ASTM D7648 D7648M-2018 Standard Practice for Active Soil Gas Sampling for Direct Push or Manual-Driven Hand-Sampling Equipment.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7648 12D7648/D7648M 18Standard Practice forActive Soil Gas Sampling for Direct Push or Manual-DrivenHand-Sampling Equipment1This standard is issued under the fixed designation D7648;D7648/D7648M; the number immediately following the designation indicatesthe year of original adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This practice details the collection of active soil gas samples using a
3、variety of sample collection techniques with toolingassociated with direct push drilling technology (DPT) (DP) or manual-driven hand-sampling equipment, for the express purposeof conducting soil gas surveys.1.2 This practice proceeds on the premise that soil gas surveys are primarily used for two (2
4、) purposes,purposes: 1)1) as apreliminary site investigative tool and 2)2) for the monitoring of ongoing remediation activities.activities (D7663).1.3 The practicality of field use demands that soil gas surveys are relatively accurate, as well as being simple, quick, andinexpensive. This guide sugge
5、sts that the objective of soil gas surveys is linked to three factors:1.3.1 VOC detection and quantitation, including determination of depth of VOC contamination.1.3.2 Sample retrieval ease and time.1.3.3 Cost.1.4 This practice will likely may increase the awareness of a fundamental difference betwe
6、en soil gas sampling for the purposeof soil gas surveys versus sub-slab or vapor intrusion investigations or both. Specifically, the purpose of a soil gas survey is toprovide quick and inexpensive data to the investigator that will allow the investigator to 1) develop a site investigation plan thati
7、s strategic in its efforts, 2) determine success or progress of on-going remedial activities, or 3) select the most suitable subsequentinvestigation equipment, or combinations thereof. On the other hand, the objective of soil gas sampling for sub-slab and vaporintrusion investigations (1,2,3, etc.)
8、is not preliminary, but rather the end result of the site investigation or long-term precisemonitoring. As such, stringent sampling methods and protocol are necessary for precise samples and data collection.1.5 Details included in this practice include a broad spectrum of practices and applications
9、of soil gas surveys, including:1.5.1 Sample recovery and handling,1.5.2 Sample analysis,1.5.3 Data interpretation, and1.5.4 Data reporting.1.6 UnitsThe values stated in either SI units or Inch-pound units given in brackets are to be regarded separately as standard.The values stated in each system ma
10、y not be exact equivalents; therefore, each system shall be used independently of the other.Combining values from the two systems may result in non-conformance with the standard.1.7 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in
11、PracticeD6026.1.7.1 The procedures used to specify how data are collected/recorded and calculated in the standard are regarded as the industrystandard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do notconsider material variat
12、ion, purpose for obtaining the data, special purpose studies, or any consideration for the users objectives;and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations.It is beyond the scope of this standard to consider significant
13、 digits used in analysis methods for engineering data.1.8 This practice suggestsoffers a variety of approaches useful to conducting successful soil gas surveys but set of instructionsfor performing one or more specific operations. This standard cannot replace education or experience and should be us
14、ed inconjunction with professional judgment. Not all aspects of this practice may be applicable in all circumstances. This ASTM1 This practice is under the jurisdiction of ASTM Committee D18 on Soil and Rock and is the direct responsibility of Subcommittee D18.21 on Groundwater and VadoseZone Invest
15、igations.Current edition approved March 1, 2012Dec. 1, 2018. Published April 2012December 2018. Originally approved in 2012. Last previous edition approved in 2012 asD7648 12. DOI: 10.1520/D7648-12.10.1520/D7648_D7648M-18.This document is not an ASTM standard and is intended only to provide the user
16、 of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as
17、published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1standard is not intended to represent or replace the standard
18、 of care by which the adequacy of a given professional service mustbe judged, nor should this document be applied without consideration of a projectsprojects many unique aspects. The word“Standard” in the title of this document means only that the document has been approved through the ASTM consensu
19、s process.1.7 This practice offers an organized collection of information or a series of options and does not recommend a specific courseof action. The success of any one soil gas survey methodology is strongly dependent upon the environment in which it is applied.1.9 This practice is not to be used
20、 for long term monitoring of contaminated sites or for site closure conformation.confirmation.1.10 This practice is not to be used for passive determination of flow patterns at contaminated sites.1.11 This practicestandard does not purport to address all of the safety concerns, if any, associated wi
21、th its use. It is theresponsibility of the user of this practicestandard to establish appropriate safety safety, health, and healthenvironmental practicesand determine the applicability of regulatory limitations prior to use.1.12 This practice does not purport to set standard levels of acceptable ri
22、sk. Use of this practice for purposes of risk assessmentis wholly the responsibility of the user.1.13 Concerns of practitioner liability or protection from or release from such liability, or both, are not addressed by thispractice.1.14 This international standard was developed in accordance with int
23、ernationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D653
24、Terminology Relating to Soil, Rock, and Contained FluidsD1356 Terminology Relating to Sampling and Analysis of AtmospheresD1357 Practice for Planning the Sampling of the Ambient AtmosphereD1452 Practice for Soil Exploration and Sampling by Auger BoringsD3249 Practice for General Ambient Air Analyzer
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7648D7648M2018STANDARDPRACTICEFORACTIVESOILGASSAMPLINGFORDIRECTPUSHORMANUALDRIVENHANDSAMPLINGEQUIPMENTPDF

链接地址:http://www.mydoc123.com/p-1243755.html