《UL SUBJECT 508B-2006 Outline of Investigation for Relays Used in Information Technology Equipment (Issue 2)《信息技术设备用继电器调查大纲 发布编号 2》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 508B-2006 Outline of Investigation for Relays Used in Information Technology Equipment (Issue 2)《信息技术设备用继电器调查大纲 发布编号 2》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNovember 15, 20061SUBJECT 508BOUTLINE OF INVESTIGATIONFORRELAYS USED IN INFORMATION TECHNOLOGY EQUIPMENTIssue Number: 2NOVEMBER 15, 2006Summary of TopicsThis new issue of SU 508B is being issued
2、through ULs electronicpublishing system to ensure format uniformity between the PDF andHTML versions of the document. No substantive changes have beenincorporated in the document.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the req
3、uirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2006 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNOVEMBER 15, 2006SUBJECT 508B2No Text on
4、This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Glossary .43 General 5CONSTRUCTION4 Spacings .65 Securement of Wiring and Parts 76 Flammability of Materials .7PERFORMANCE7 Electric Strength Test 78 Prim
5、ary Power Isolation (optional) .79 Safety Interlocks (optional) .8NOVEMBER 15, 2006 SUBJECT 508B 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This Outline of Investigation covers the requirements applicable to relays
6、 intended for use inaccordance with the Standard for Safety of Information Technology Equipment Including ElectricalBusiness Equipment, UL 1950.1.2 The relays covered are limited to those with air gap isolation or a barrier of solid insulation betweencoil and contacts (electromechanical types) or be
7、tween input and output circuits (solid state types). Thisseparation between coil and contacts or input and output circuits shall comply with the requirements forbasic, double, or reinforced insulation as specified in UL 1950.1.3 Limiting impedance, as described in the Standard for Industrial Control
8、 Equipment, UL 508, is notconsidered a suitable means of isolation between input and output circuits.1.4 An optical isolator may be used in solid state relays to comply with the air gap or solid insulationrequirement.2 Glossary2.1 For the purpose of this Outline of Investigation, the following defin
9、itions apply. See UL 1950 foradditional definitions.2.2 BASIC INSULATION Insulation that provides basic protection against the risk of electric shock.2.3 DOUBLE INSULATION Insulation comprising both basic insulation and supplementary insulation.2.4 EXTRA-LOW VOLTAGE (ELV) A voltage between conductor
10、s or between a conductor and earthground not exceeding 42.4 V peak, or 60 V dc, existing in a secondary circuit that is separated fromhazardous voltage by at least basic insulation, but does not meet the requirements for a SELV circuit ora limited current circuit as defined in UL 1950.2.5 HAZARDOUS
11、VOLTAGE A voltage exceeding 42.4 V peak, or 60 V dc, existing in a circuit thatdoes not meet the requirements for a limited current circuit as defined in UL 1950.2.6 OPERATIONAL INSULATION Insulation needed for the correct operation of the equipment.Operational insulation does not protect against ri
12、sk of electric shock. It may, however, provide a degreeof protection against the risk of ignition and exposure to fire.2.7 PRIMARY CIRCUIT An internal circuit that is directly connected to the external supply mains orother equivalent source (such as a motor-generator set) that supplies the electric
13、power. It includes theprimary windings of transformers, motors, other loading devices, and the means of connection to supplymains.2.8 REINFORCED INSULATION A single insulation that provides protection against risk of electricshock equivalent to double insulation under the conditions specified in UL
14、1950. Reinforced insulationdoes not need to be in one homogeneous piece. It may comprise several layers that cannot be testedas supplementary or basic insulation.NOVEMBER 15, 2006SUBJECT 508B4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2.9
15、 SAFETY EXTRA-LOW VOLTAGE (SELV) CIRCUIT A secondary circuit that is so designed andprotected that under normal and single fault conditions the voltage between any two accessible parts, orbetween one accessible part and the equipment protective earthing terminal for Class I equipment, doesnot exceed
16、 a safe value. Under normal conditions this limit is either 42.4 V peak, or 60 V dc. Underfault conditions, higher limits are specified in UL 1950 for transient deviation.2.10 SAFETY INTERLOCK A means either of reducing the likelihood of accessing a hazardous areauntil the hazard is removed or of au
17、tomatically removing the hazardous condition if access is gained.2.11 SECONDARY CIRCUIT A circuit that has no direct connection to primary power and derives itspower from a transformer, converter, or equivalent isolation device situated within the equipment. Somesolid state devices may provide equiv
18、alent isolation.2.12 SUPPLEMENTARY INSULATION Independent insulation applied in addition to basic insulationin order to reduce the risk of electric shock in the event of a failure of the basic insulation.3 General3.1 In addition to complying with the applicable requirements in UL 1950, the relays sh
19、all also comply withthe applicable requirements in the Standard for Industrial Control Equipment, UL 508. References to UL1950 are to the Second Edition of that standard, and references to UL 508 are to the Sixteenth Edition ofthat Standard.3.2 The following are two examples of typical relay constru
20、ctions covered by this Outline of Investigation.These examples specify the circuit construction and the corresponding insulation that would be requiredfor their end-product application.a) A relay containing hazardous voltage and SELV circuits. This relay construction requiresdouble or reinforced ins
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT508B2006OUTLINEOFINVESTIGATIONFORRELAYSUSEDININFORMATIONTECHNOLOGYEQUIPMENTISSUE2 信息技术 备用 继电器

链接地址:http://www.mydoc123.com/p-1069449.html