UL SUBJECT 1384-2015 UL Outline for Investigation Water-Based Automatic Extinguisher Units (Issue 3)《水基自动灭火装置的UL调查大纲 (议题3)》.pdf
《UL SUBJECT 1384-2015 UL Outline for Investigation Water-Based Automatic Extinguisher Units (Issue 3)《水基自动灭火装置的UL调查大纲 (议题3)》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 1384-2015 UL Outline for Investigation Water-Based Automatic Extinguisher Units (Issue 3)《水基自动灭火装置的UL调查大纲 (议题3)》.pdf(48页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJune 11, 20151UL 1384Outline of Investigation for Water-Based Automatic Extinguisher UnitsISSUE NO: 3June 11, 2015Summary of TopicsThe Third Issue of this Outline of Investigation revises labelin
2、grequirements to point the user to the applicable governing regulations.COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJUNE 11, 2015UL 13842No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZE
3、D FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 Components 53 Units of Measurement .54 Undated References 65 Glossary .6CONSTRUCTION6 General 77 Controls and Indicators 88 Caps, Valves, and Closures 99 Pressure Vessels and Cylinders 910 Pressure Re
4、lief Devices for Pressure Vessels and Cylinders .1311 Gaskets and O Rings 1312 Pressure Gauges for Pressure Vessels and Cylinders .1313 Puncturing Mechanisms .1414 Siphon Tubes 1415 Extinguishing Agent .1516 Expellant Gases 1517 Polymeric Materials and Nonmetallic Parts .1518 Anti-Recoil Devices .16
5、19 Gas Cartridges .1620 Pressure Switches 1621 Flexible Hose Assemblies Used for Distribution of Agent 1722 Nozzles 1723 Protective Covers .1724 Strainer and Filter .17PERFORMANCE25 General 1826 Fire Test Total Flooding Protection 1826.1 General .1826.2 Class A fire tests .1926.3 Class B fire tests
6、.2026.4 Automatic operation extinguishment tests .2227 Locking Indicator Test .2428 Nozzle Water Flow Test .2429 Nozzle Function Test 2530 Nozzle Specific Corrosion Tests 2530.1 Sulfur dioxide/carbon dioxide corrosion .2530.2 Hydrogen sulfide corrosion 2630.3 Salt spray corrosion 2631 Agent Exposure
7、 Test 2732 Flow Distribution Tests 2733 Hydrostatic Pressure Test .2833.1 Pressure vessels and gas cartridges 2833.2 Other devices subject to pressure 29JUNE 11, 2015 UL 1384 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL33.3 Test method .3
8、034 30-Day Elevated Temperature Test .3035 Temperature Cycling Test .3036 Salt Spray Corrosion Test .3137 500 Cycle Operation Test 3138 One-Year Time Leakage Test 3239 Mounting Device Test .3240 Flexible Hose Assembly Low Temperature Test 3341 Flexible Hose Assembly Cycling Test .3342 Flexible Hose
9、Assembly Fire Exposure Test .3343 Pneumatic Operation Test .3444 Pressure Relief Tests .3445 Elastomeric Parts Test 3546 10-Day Moist Ammonia Air Stress Cracking Test .3547 Aging Tests - Plastic Materials .3647.1 Air-oven aging test .3647.2 Exposure to extinguishing agent test .3847.3 Light and wate
10、r test 3848 Calibration Test - Gauges and Indicators 3949 Burst Strength Test - Gauges and Indicators .3950 Overpressure Test - Gauges .4051 Impulse Test - Gauges 4052 Pressure Gauge Relief Test 4053 Water Resistance Test - Gauges and Indicators 4154 Nameplate Exposure Tests 4155 Nameplate Adhesion
11、Test .4156 Nameplate Abrasion Test 42MANUFACTURING AND PRODUCTION TESTS57 General 4257.1 Manufacturers Tests .4257.2 Hydrostatic pressure test- shells .4257.3 Non-DOT gas cartridges 4357.4 Gauge calibration test 4357.5 Leakage test .43PACKING FOR SHIPMENT58 General 44MARKINGS59 General 44INSTALLATIO
12、N INSTRUCTIONS60 Installation, Operation, and Maintenance Instruction Manual .4661 Owners Manual 47JUNE 11, 2015UL 13844UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover the construction and operat
13、ion of water-based automatic extinguisher unitsintended for total flooding applications when installed, inspected, tested, and maintained in accordancewith the manufacturers instructions.1.2 Automatic extinguisher units do not have a manual means of operation, and are not intended forprotection of f
14、ire risks larger than those specified in the manufacturers instructions for a single unit byusing multiple units.2 Components2.1 Except as indicated in 2.2, a component of a product covered by this outline shall comply with therequirements for that component.2.2 A component is not required to comply
15、 with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline; orb) Is superseded by a requirement in this outline.2.3 A component shall be used in accordance with its rating established for the intend
16、ed conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific co
17、nditions.3 Units of Measurement3.1 The metric unit shall be designated as the official unit for purposes of this standard. Where values ofmeasurement are specified in both SI and English units, either unit is used. In cases of dispute, the metricunit shall be used.JUNE 11, 2015 UL 1384 5UL COPYRIGHT
18、ED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL4 Undated References4.1 Any undated reference to a code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.5 Glossary5.1
19、 For the purpose of this outline, the following definitions apply.5.2 ACTUATOR ASSEMBLY A pressure vessel pressurized with an inert gas or a liquid and inert gasthat includes a valve; or a gas cartridge pressurized with an inert gas that includes a puncture disc, whichupon automatic means of actuati
20、on, releases pressure resulting in the discharge process.5.3 AUTOMATIC EXTINGUISHER UNIT A unit that has no manual means of actuation and dischargesextinguishing agent upon thermal actuation, and is intended for use in a normally unoccupied space andis limited to a single protected area.5.4 CYLINDER
21、/VALVE ASSEMBLY A container that incorporates a valve and that provides storage ofthe extinguishing agent and expellant gas until the valve is actuated. For cartridge operated units, thisassembly includes the dry chemical storage container and cartridge mechanism. When actuated, thevalve releases th
22、e agent into the distribution network of the extinguisher unit.5.5 DISCHARGE NOZZLE A device that is used to uniformly distribute the extinguishing agent over orinto a specific area, or within a specific volume, or both.5.6 DISCHARGE RATE The ratio of the quantity of agent discharged from a nozzle t
23、o the dischargetime measured within 1 second. When a minimum discharge rate is indicated, reference is made to theminimum quantity of agent discharged and the time measured within 1 second.5.7 DISCHARGE TIME The time interval between the first appearance of extinguishing agent at thenozzle and the t
24、ime at which the discharge becomes predominantly gaseous.5.8 EXPELLANT GAS Dry nitrogen, dry air, or other gas used to facilitate the discharge of theextinguishing agent.5.9 GAS CARTRIDGE A container that provides storage for an expellant gas.5.10 HEPTANE A commercial grade hydrocarbon used as a tes
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT13842015ULOUTLINEFORINVESTIGATIONWATERBASEDAUTOMATICEXTINGUISHERUNITSISSUE3 自动 灭火 装置 UL 调查 大纲

链接地址:http://www.mydoc123.com/p-1069167.html