UL 763 CRD-2013 UL Standard for Safety Motor-Operated Commercial Food Preparing Machines - Section Paragraph Reference 35 36 Subject Leakage Current Limit for Stationary Ice Bever.pdf
《UL 763 CRD-2013 UL Standard for Safety Motor-Operated Commercial Food Preparing Machines - Section Paragraph Reference 35 36 Subject Leakage Current Limit for Stationary Ice Bever.pdf》由会员分享,可在线阅读,更多相关《UL 763 CRD-2013 UL Standard for Safety Motor-Operated Commercial Food Preparing Machines - Section Paragraph Reference 35 36 Subject Leakage Current Limit for Stationary Ice Bever.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): IPSTStandard Number: UL 763Standard Title: Standard for Motor-Operated Commercial Food Preparing MachinesEdition Date: January 31, 2012Edition Number: 4Secti
3、on / Paragraph Reference: 35, 36Subject: Leakage Current Limit for Stationary Ice/Beverage Dispensers with EMISuppression FilteringDECISION:35.1 When tested in accordance with 35.3 - 35.8, the leakage current of a cord- and plug-connected icedispenser or counter-top, portable machine weighing 40 lbs
4、 or less, rated for a nominal 120- or 240-voltsingle-phase supply shall not exceed 0.5 mA.Exception: Those conductive parts of a stationary ice dispenser that comply with all of the specificationsin Items (a) through (d) below shall have a leakage current from simultaneously accessible parts to theg
5、rounded supply conductor no greater than 3.5 mA. The leakage current between simultaneouslyaccessible parts shall not exceed 0.5 mA.a) The product is provided with electromagnetic interference (EMI) suppression filtering.b) The product is equipped with a grounding-type supply cord and plug.c) The pr
6、oduct is not intended for outdoor installation.d) There is a low probability that high leakage conductive parts will be contacted during normaluse.1) The front of an ice dispenser is considered likely to be contacted in normal use.However, the recessed area where ice or beverages are dispensed (back
7、splashsurround) is considered to have a low probability of contact during normal use.2) The sides of an ice dispenser are considered likely to be contacted in normal use,unless installation instructions are provided for installing in a manner that the sides areprotected from unintentional contact, s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL763CRD2013ULSTANDARDFORSAFETYMOTOROPERATEDCOMMERCIALFOODPREPARINGMACHINESSECTIONPARAGRAPHREFERENCE3536SUBJECTLEAKAGECURRENTLIMITFORSTATIONARYICEBEVERPDF

链接地址:http://www.mydoc123.com/p-1068906.html