UL 20-2018 UL Standard for Safety General-Use Snap Switches (Fourteenth Edition).pdf
《UL 20-2018 UL Standard for Safety General-Use Snap Switches (Fourteenth Edition).pdf》由会员分享,可在线阅读,更多相关《UL 20-2018 UL Standard for Safety General-Use Snap Switches (Fourteenth Edition).pdf(107页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 20 General-Use Snap Switches STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZ
2、ED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for General-Use Snap Switches, UL 20 Fourteenth Edition, Dated July 20, 2018 Summary of Topics This new edition of the ANSI/UL 20, includes the following specic changes in requirements: Marking Requirements
3、 for Leaded Devices including those with Separable Terminal Assemblies Flush Switches Employing a Combination Wire Binding/Pressure -Type Terminal Construction AC Only Flush Switch with Integral Power Supply with Class 2 Output Connectors Accommodate Electronic Ballasts up to 347V Additional Editori
4、al and Technical Revisions to Improve Clarity The new and revised requirements are substantially in accordance with Proposal(s) on this subject dated February 2, 2018. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any
5、means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event
6、 will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the
7、 possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expe
8、nse, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. JULY 20, 2018 UL 20 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTIO
9、N OR DISTRIBUTION WITHOUT PERMISSION FROM UL JULY 20, 2018 UL 20 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Association of Standardization and Certication NMX-J-005-ANCE First Edition Canadian Standards Associati
10、on CAN/CSA-C22.2 No. 111-18 Fifth Edition Underwriters Laboratories Inc. UL 20 Fourteenth Edition General-Use Snap Switches July 20, 2018 ANSI/UL 20-2018UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This standard
11、is issued jointly by the Association of Standardization and Certication (ANCE), the Canadian Standards Association (operating as “CSA Group”), and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard may be submitted to ANCE, CSA Group, or UL at anytim
12、e. Revisions to this standard will be made only after processing according to the standards development procedures of ANCE, CSA Group, and UL. CSA Group and UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of issue. ANCE will incorp
13、orate the same revisions into a new edition of the standard bearing the same date of issue as the CSA Group and UL pages. Copyright 2018 Rights reserved in favor of ANCE. ISBN 978-1-4883-1315-8 2018 Canadian Standards Association All rights reserved. No part of this publication may be reproduced in
14、any form whatsoever without the prior permission of the publisher. This Standard is subject to review within ve years from the date of publication, and suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following informatio
15、n to inquirescsagroup.org and include Proposal for change in the subject line: Standard designation (number); relevant clause, table, and/or gure number; wording of the proposed change; and rationale for the change. To purchase CSA Group Standards and related publications, visit CSA Groups Online St
16、ore at shop.csa.ca or call toll-free 1-800-463-6727 or 416-747-4044. Copyright 2018 Underwriters Laboratories Inc. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, an
17、d rights regarding those Standards shall remain the sole and exclusive property of UL. This ANSI/UL Standard for Safety consists of the Fourteenth Edition. The most recent designation of ANSI/UL 20 as an American National Standard (ANSI) occurred on July 20, 2018. ANSI approval for a standard does n
18、ot include the Cover Page, Transmittal Pages, Title Page (front and back), or the Preface. TheDepartmentofDefense(DoD)hasadoptedUL20onDecember4,1981.Thepublicationofrevised pages or a new edition of this Standard will not invalidate the DoD adoption. Comments or proposals for revisions on any part o
19、f the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. To purchase UL Standards, visit ULs Standards Sales Site at http:/ HowToOrder.aspx or call toll-free 1-888-853-3503.UL
20、COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface .6 1 Scope .7 2 Denitions8 3 General 9 3.1 Components .9 3.2 Units of Measurement10 3.3 Reference Publications.10 4 Construction.13 4.1 Enclosure 13 4.2 Lining 15 4.3 Bushings and
21、 Strain Relief .15 4.4 Bases and Bodies .16 4.5 Current-Carrying Parts .18 4.6 Separable Jumper Connector for Separable Terminals .23 4.7 Separable Terminal Assembly 23 4.8 Insulating Material .23 4.9 Actuating Members 24 4.10 Creepage Distances, Clearances, and Distances Through Sealing Compounds 2
22、4 4.11 Assembly .26 4.12 Provision for Grounding .27 5 Testing .28 5.1 General 28 5.2 Test Sequence 29 5.3 Tungsten-Filament-Lamp Load Characteristics 35 5.4 Assembly Test 37 5.5 Test Conditions .38 5.6 Overload Test.38 5.7 Endurance Test .41 5.8 Temperature Test .42 5.9 Dielectric Voltage-Withstand
23、 Test44 5.10 Security of Switch Leads Test .45 5.11 Push-In Terminal Tests .45 5.12 Effect of Heat on Actuating Members Test 46 5.13 Switching Mechanism Test 46 5.14 Strain-Relief Test.48 5.15 Fault Current Test 48 5.16 Crushing Test49 5.17 Resistance to Heat Test.49 5.18 Door Switch Assembly Test .
24、49 5.19 Retention of Tab Connection Test 49 5.20 Separable Connector Pull Test.50 5.21 Mold Stress Relief Test .50 5.22 Separable Terminal Assembly Humidity Conditioning Followed By Dielectric Test 51 5.23 Short Circuit Withstand Test 51 5.24 Latching Mechanism Test .52 5.25 Abnormal Overload Test 5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL202018ULSTANDARDFORSAFETYGENERALUSESNAPSWITCHESFOURTEENTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-1067763.html